Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Surface Refractive Index Shift of Kalifilcon A Compared With Dailies Total1 and Precision1 Lenses

3 augusti 2026 uppdaterad av: Bausch & Lomb Incorporated

Evaluation of Surface Refractive Index Shift and Lens Absorption / Adsorption of Tear Components of Commercially Available Kalifilcon A Lenses Compared to Dailies Total1 and Precision1

This was a single-site, bilateral, repeated-measures insertion study in habitual soft contact lens wearers. Ten participants were enrolled. All participants attended a Screening/Dispensing Visit at which informed consent was obtained and eligibility was assessed. Eligible participants then wore each of three commercially available daily disposable soft contact lens types - kalifilcon A (Bausch + Lomb), Dailies Total1 (delefilcon A, Alcon) and Precision1 (verofilcon A, Alcon), all -3.00 D - bilaterally for wear times of 0.5, 1, 3, 5 and 10 minutes over a total of 6 study visits. A new lens pair was inserted for each wear time, with a 3-5 minute washout period between lens pairs. Immediately following removal, the right-eye lens was measured for surface refractive index on a Metricon M-2010 Prism Coupler.

Studieöversikt

Detaljerad beskrivning

Rationale: earlier work (ROC2-20-012) showed a change in surface refractive index for Dailies Total1 (delefilcon A) and Precision1 (verofilcon A) lenses after 5 minutes of wear, attributed to a change in surface water content. ROC2-21-007 was designed to determine whether that change occurs in less than 5 minutes. Three study lenses (one test, two controls) were each worn bilaterally. Wear times of 0.5, 1 and 3 minutes were completed at one visit and 5 and 10 minutes at another visit for each lens type, giving 6 visits of approximately 30 minutes each, each on a separate day; the clinical investigation took approximately 2 weeks. Lens type order followed the study randomization schedule prepared before enrolment by an unmasked statistician not otherwise involved in the study; unmasked study personnel dispensed and collected study materials so that the participant and Investigator remained masked. Endpoint: surface refractive index of the worn right-eye lens, measured on a Metricon M-2010 Prism Coupler, compared with unworn (baseline) values for the same lens types. Continuous data were summarized with n, mean, standard deviation, median, minimum and maximum, and paired t-tests were used to compare unworn with worn values, with p < 0.05 considered statistically significant.

Studietyp

Interventionell

Inskrivning (Faktisk)

10

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • New York
      • Rochester, New York, Förenta staterna, 14609
        • Bausch & Lomb Incorporated

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Ja

Beskrivning

Inclusion Criteria:

  1. Be 18 years or older and have full legal capacity to volunteer.
  2. Have physiologically normal anterior segments not exhibiting clinically significant biomicroscopy findings.
  3. Have no active ocular disease or allergic conjunctivitis.
  4. Not be using any topical ocular medications.
  5. Be willing and able to follow instructions.
  6. Have signed a statement of informed consent.

Exclusion Criteria:

  1. Participating in a conflicting study in the opinion of the Investigator.
  2. Considered by the Investigator to not be a suitable candidate for participation.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Grundläggande vetenskap
  • Tilldelning: N/A
  • Interventionsmodell: Enskild gruppuppgift
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Övrig: All Participants: kalifilcon A, Then Dailies Total1, Then Precision1
Each participant wore all three study lens types bilaterally, one lens type per pair of visits, in the order specified by the study randomization schedule (kalifilcon A, then Dailies Total1, then Precision1). For each lens type a new lens pair was inserted for each wear time of 0.5, 1, 3, 5 and 10 minutes, with a 3-5 minute washout period between lens pairs. Wear times of 0.5, 1 and 3 minutes were completed at one visit and 5 and 10 minutes at another visit, for a total of 6 visits. Immediately after removal the right-eye lens was measured for surface refractive index on a Metricon M-2010 Prism Coupler.
Commercially available Infuse (kalifilcon A) daily disposable spherical soft contact lens, -3.00 D, worn bilaterally for 0.5, 1, 3, 5 and 10 minutes.
Andra namn:
  • Ingjuta
Commercially available Dailies Total1 (delefilcon A) daily disposable spherical soft contact lens (Alcon), -3.00 D, worn bilaterally for 0.5, 1, 3, 5 and 10 minutes.
Commercially available Precision1 (verofilcon A) daily disposable spherical soft contact lens (Alcon), -3.00 D, worn bilaterally for 0.5, 1, 3, 5 and 10 minutes.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Surface Refractive Index of Worn Lenses
Tidsram: Unworn lens (baseline) and immediately after 0.5, 1, 3, 5, and 10 minutes of lens wear
Immediately following lens removal, the right-eye worn lens for each participant was measured for surface refractive index on a Metricon M-2010 Prism Coupler. A new lens pair was worn for each wear time. Surface refractive index is a dimensionless ratio and has no units.
Unworn lens (baseline) and immediately after 0.5, 1, 3, 5, and 10 minutes of lens wear

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Huvudutredare: Jeffery Schafer, OD, MS, Bausch & Lomb Incorporated

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

7 april 2021

Primärt slutförande (Faktisk)

15 april 2021

Avslutad studie (Faktisk)

15 april 2021

Studieregistreringsdatum

Först inskickad

7 april 2021

Först inskickad som uppfyllde QC-kriterierna

8 april 2021

Första postat (Faktisk)

12 april 2021

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

5 augusti 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

3 augusti 2026

Senast verifierad

1 augusti 2026

Mer information

Termer relaterade till denna studie

Nyckelord

Andra studie-ID-nummer

  • ROC2-21-007

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

IPD-planbeskrivning

Individual participant data will not be shared. This was an internal Bausch + Lomb device performance study; source data are retained in the Trial Master File.

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Ja

produkt tillverkad i och exporterad från U.S.A.

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera