Surface Wear of PEEK Clasp Against Zirconia Full-Coverage Restored Abutments in Distal Extension Removable Partial Dentures (PEEKWear)

13 juli 2026 uppdaterad av: Mansoura University

Clinical Evaluation of Surface Wear of PEEK Clasps Against Zirconia Full-Coverage Restored Abutments in Distal Extension Removable Partial Dentures

This prospective clinical comparative study will evaluate the surface wear of BioHPP (modified polyetheretherketone) clasps opposing either natural tooth abutments or zirconia full-coverage abutments in mandibular bilateral distal extension removable partial dentures. Ten participants will be randomly assigned to two equal groups. Surface topography changes of the clasp fitting surfaces will be assessed using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months. The findings will help determine the influence of abutment material on the wear behavior of BioHPP clasps and provide evidence for selecting appropriate abutment materials in removable partial denture treatment.

Studieöversikt

Studietyp

Interventionell

Inskrivning (Faktisk)

10

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

      • Al Mansurah, Egypten
        • Faculty of Dentistry Mansoura University

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen

Tar emot friska volontärer

Nej

Beskrivning

Inclusion Criteria:

Adults aged 40-50 years. Mandibular Kennedy Class I partial edentulism. Bilateral distal extension edentulous areas. Presence of healthy canines and first premolars suitable as abutment teeth. Adequate oral hygiene and healthy periodontal condition. Adequate interarch space for removable partial denture fabrication. Ability and willingness to attend all scheduled follow-up visits and provide written informed consent.

Exclusion Criteria:

Systemic diseases or medications that could affect bone or soft tissue healing. Active periodontal disease or poor oral hygiene. Severe parafunctional habits (e.g., bruxism or clenching). Smoking. Pregnancy or lactation. Allergy or hypersensitivity to any study materials. Inability to comply with study procedures or follow-up visits.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Grundläggande vetenskap
  • Tilldelning: Randomiserad
  • Interventionsmodell: Parallellt uppdrag
  • Maskning: Dubbel

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: BioHPP Clasps Opposing Natural Tooth Abutments
Participants receive mandibular bilateral distal extension removable partial dentures with BioHPP clasps engaging natural tooth abutments. The surface topography of the clasp fitting surfaces will be evaluated using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months to assess surface wear.
BioHPP Removable Partial Denture Framework with Natural Tooth Abutments
Experimentell: BioHPP Clasps Opposing Zirconia Abutmen
Participants receive mandibular bilateral distal extension removable partial dentures with BioHPP clasps engaging zirconia full-coverage abutments. The surface topography of the clasp fitting surfaces will be evaluated using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months to assess surface wear.
BioHPP Removable Partial Denture Framework with Zirconia Abutments

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Surface topography changes of BioHPP clasp fitting surfaces
Tidsram: Baseline (denture insertion), 6 months, and 12 months
Surface wear of BioHPP clasp fitting surfaces assessed by scanning electron microscopy (SEM) and digital morphometric analysis
Baseline (denture insertion), 6 months, and 12 months

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

1 mars 2024

Primärt slutförande (Faktisk)

1 september 2024

Avslutad studie (Faktisk)

1 mars 2025

Studieregistreringsdatum

Först inskickad

13 juli 2026

Först inskickad som uppfyllde QC-kriterierna

13 juli 2026

Första postat (Faktisk)

16 juli 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

16 juli 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

13 juli 2026

Senast verifierad

1 juni 2023

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • PROS-PEEK-2025-01

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .