Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Surface Wear of PEEK Clasp Against Zirconia Full-Coverage Restored Abutments in Distal Extension Removable Partial Dentures (PEEKWear)

13. Juli 2026 aktualisiert von: Mansoura University

Clinical Evaluation of Surface Wear of PEEK Clasps Against Zirconia Full-Coverage Restored Abutments in Distal Extension Removable Partial Dentures

This prospective clinical comparative study will evaluate the surface wear of BioHPP (modified polyetheretherketone) clasps opposing either natural tooth abutments or zirconia full-coverage abutments in mandibular bilateral distal extension removable partial dentures. Ten participants will be randomly assigned to two equal groups. Surface topography changes of the clasp fitting surfaces will be assessed using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months. The findings will help determine the influence of abutment material on the wear behavior of BioHPP clasps and provide evidence for selecting appropriate abutment materials in removable partial denture treatment.

Studienübersicht

Studientyp

Interventionell

Einschreibung (Tatsächlich)

10

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Al Mansurah, Ägypten
        • Faculty of dentistry Mansoura university

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

Adults aged 40-50 years. Mandibular Kennedy Class I partial edentulism. Bilateral distal extension edentulous areas. Presence of healthy canines and first premolars suitable as abutment teeth. Adequate oral hygiene and healthy periodontal condition. Adequate interarch space for removable partial denture fabrication. Ability and willingness to attend all scheduled follow-up visits and provide written informed consent.

Exclusion Criteria:

Systemic diseases or medications that could affect bone or soft tissue healing. Active periodontal disease or poor oral hygiene. Severe parafunctional habits (e.g., bruxism or clenching). Smoking. Pregnancy or lactation. Allergy or hypersensitivity to any study materials. Inability to comply with study procedures or follow-up visits.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Grundlegende Wissenschaft
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: BioHPP Clasps Opposing Natural Tooth Abutments
Participants receive mandibular bilateral distal extension removable partial dentures with BioHPP clasps engaging natural tooth abutments. The surface topography of the clasp fitting surfaces will be evaluated using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months to assess surface wear.
BioHPP Removable Partial Denture Framework with Natural Tooth Abutments
Experimental: BioHPP Clasps Opposing Zirconia Abutmen
Participants receive mandibular bilateral distal extension removable partial dentures with BioHPP clasps engaging zirconia full-coverage abutments. The surface topography of the clasp fitting surfaces will be evaluated using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months to assess surface wear.
BioHPP Removable Partial Denture Framework with Zirconia Abutments

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Surface topography changes of BioHPP clasp fitting surfaces
Zeitfenster: Baseline (denture insertion), 6 months, and 12 months
Surface wear of BioHPP clasp fitting surfaces assessed by scanning electron microscopy (SEM) and digital morphometric analysis
Baseline (denture insertion), 6 months, and 12 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

1. März 2024

Primärer Abschluss (Tatsächlich)

1. September 2024

Studienabschluss (Tatsächlich)

1. März 2025

Studienanmeldedaten

Zuerst eingereicht

13. Juli 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

13. Juli 2026

Zuerst gepostet (Tatsächlich)

16. Juli 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

16. Juli 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

13. Juli 2026

Zuletzt verifiziert

1. Juni 2023

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • PROS-PEEK-2025-01

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Partielle Zahnlosigkeit

3
Abonnieren