Surface Wear of PEEK Clasp Against Zirconia Full-Coverage Restored Abutments in Distal Extension Removable Partial Dentures (PEEKWear)

13 juli 2026 bijgewerkt door: Mansoura University

Clinical Evaluation of Surface Wear of PEEK Clasps Against Zirconia Full-Coverage Restored Abutments in Distal Extension Removable Partial Dentures

This prospective clinical comparative study will evaluate the surface wear of BioHPP (modified polyetheretherketone) clasps opposing either natural tooth abutments or zirconia full-coverage abutments in mandibular bilateral distal extension removable partial dentures. Ten participants will be randomly assigned to two equal groups. Surface topography changes of the clasp fitting surfaces will be assessed using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months. The findings will help determine the influence of abutment material on the wear behavior of BioHPP clasps and provide evidence for selecting appropriate abutment materials in removable partial denture treatment.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Werkelijk)

10

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Al Mansurah, Egypte
        • Faculty of Dentistry Mansoura University

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

Adults aged 40-50 years. Mandibular Kennedy Class I partial edentulism. Bilateral distal extension edentulous areas. Presence of healthy canines and first premolars suitable as abutment teeth. Adequate oral hygiene and healthy periodontal condition. Adequate interarch space for removable partial denture fabrication. Ability and willingness to attend all scheduled follow-up visits and provide written informed consent.

Exclusion Criteria:

Systemic diseases or medications that could affect bone or soft tissue healing. Active periodontal disease or poor oral hygiene. Severe parafunctional habits (e.g., bruxism or clenching). Smoking. Pregnancy or lactation. Allergy or hypersensitivity to any study materials. Inability to comply with study procedures or follow-up visits.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Fundamentele wetenschap
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: BioHPP Clasps Opposing Natural Tooth Abutments
Participants receive mandibular bilateral distal extension removable partial dentures with BioHPP clasps engaging natural tooth abutments. The surface topography of the clasp fitting surfaces will be evaluated using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months to assess surface wear.
BioHPP Removable Partial Denture Framework with Natural Tooth Abutments
Experimenteel: BioHPP Clasps Opposing Zirconia Abutmen
Participants receive mandibular bilateral distal extension removable partial dentures with BioHPP clasps engaging zirconia full-coverage abutments. The surface topography of the clasp fitting surfaces will be evaluated using scanning electron microscopy (SEM) at denture insertion, 6 months, and 12 months to assess surface wear.
BioHPP Removable Partial Denture Framework with Zirconia Abutments

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Surface topography changes of BioHPP clasp fitting surfaces
Tijdsspanne: Baseline (denture insertion), 6 months, and 12 months
Surface wear of BioHPP clasp fitting surfaces assessed by scanning electron microscopy (SEM) and digital morphometric analysis
Baseline (denture insertion), 6 months, and 12 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 maart 2024

Primaire voltooiing (Werkelijk)

1 september 2024

Studie voltooiing (Werkelijk)

1 maart 2025

Studieregistratiedata

Eerst ingediend

13 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

13 juli 2026

Eerst geplaatst (Werkelijk)

16 juli 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

16 juli 2026

Laatste update ingediend die voldeed aan QC-criteria

13 juli 2026

Laatst geverifieerd

1 juni 2023

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • PROS-PEEK-2025-01

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren