此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

A Study to Evaluate the Product Feasibility of Two New Silicone Hydrogel Contact Lenses

2020年9月29日 更新者:Bausch & Lomb Incorporated
The objective of this study is to determine the clinical feasibility and to evaluate the product performance of two RD2135-01 investigational soft contact lenses (Test 1 and Test 2) developed by Bausch + Lomb. The Test lenses will be compared to both Bausch + Lomb PureVision®2 HD (high definition) soft contact lenses and Ciba Vision Air Optix Aqua soft contact lenses when used among currently adapted soft contact lens wearers.

研究概览

研究类型

介入性

注册 (实际的)

216

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • New York
      • Rochester、New York、美国、14609
        • Bausch & Lomb Incorporated

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Have physiologically normal anterior segments not exhibiting clinically significant biomicroscopy findings.
  • Be adapted wearers of soft contact lenses, wear a lens in each eye, and each lens must be of the same manufacture and brand.
  • Be correctable through spherocylindrical refraction to 32 letters (0.3 logMAR) or better (distance, high contrast) in each eye.
  • Be myopic and require lens correction from -0.50 diopters (D) to -6.00 D in each eye.
  • Must agree to wear the study lenses on a daily wear basis for the duration of the study.
  • Must be willing to use a lens care system on a regular basis.
  • If the subject requires a Washout Period, the subject must be willing to discontinue contact lens wear and be willing to wear either spectacles or no lenses during this Washout Period.

Exclusion Criteria:

  • Not correctable to 32 letters (0.3 logMAR) in each eye with soft spherical contact lenses.
  • Have an active ocular disease, any corneal infiltrative response or are using any ocular medications.
  • Have worn gas permeable (GP) contact lenses within last 30 days or PMMA lenses within last 3 months.
  • Any scar or neovascularization within the central 4mm of the cornea.
  • Any Grade 2 or greater finding during the slit lamp examination, Subjects with corneal infiltrates, of ANY GRADE, are not eligible.
  • Any "Present" finding during the slit lamp examination that, in the Investigator's judgment, interferes with contact lens wear.
  • Anisometropia (spherical equivalent) of greater than 2.00 D.
  • Any systemic disease affecting ocular health.
  • Using any systemic or topical medications that will affect ocular physiology or lens performance.
  • Aphakic.
  • Amblyopic.
  • Allergic to any component in the study products.
  • Have had any corneal surgery (ie, refractive surgery).
  • Currently wear monovision correction, multifocal, or toric contact lenses.
  • Ocular astigmatism greater than 1.00 D in either eye.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:B&L RD2135-01 lens C
Investigational Silicone hydrogel soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
实验性的:B&L RD2135-01 lens D
Investigational Silicone hydrogel soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
有源比较器:PureVision2
Bausch & Lomb High definition soft contact lenses
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
有源比较器:Ciba Vision Air Optix Aqua
Ciba Vision Air Optix Aqua soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
视力
大体时间:1周后随访
通过最小分辨率角的距离高对比度对数 (logMAR) 评估视敏度。
1周后随访

次要结果测量

结果测量
措施说明
大体时间
Symptoms and Complaints
大体时间:At 1 Week follow up
Symptoms/complaints were assessed on a scale from 0 to 100, with 0 denoting unfavorable symptoms/complaints. Symptoms/complaints were recorded for each eye based on the participant's experience with their study lenses worn for that respective treatment period. Symptoms/complaints parameters included the following: Burning/stinging upon insertion, Comfort upon insertion, Overall comfort, Comfort at end of day, Ease of handling/insertion, Ease of handling/removal, Dryness, Itchiness, Redness, Vision upon insertion, Vision, Vision in low light, Lens cleanness upon insertion, Lens cleanness upon removal, Lens cleanness, Dryness at end of day, and Overall impression.
At 1 Week follow up

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2012年4月1日

初级完成 (实际的)

2012年6月1日

研究完成 (实际的)

2012年7月1日

研究注册日期

首次提交

2012年4月23日

首先提交符合 QC 标准的

2012年4月23日

首次发布 (估计)

2012年4月24日

研究记录更新

最后更新发布 (实际的)

2020年10月22日

上次提交的符合 QC 标准的更新

2020年9月29日

最后验证

2020年9月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • 755E

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅