A Study to Evaluate the Product Feasibility of Two New Silicone Hydrogel Contact Lenses

29. September 2020 aktualisiert von: Bausch & Lomb Incorporated
The objective of this study is to determine the clinical feasibility and to evaluate the product performance of two RD2135-01 investigational soft contact lenses (Test 1 and Test 2) developed by Bausch + Lomb. The Test lenses will be compared to both Bausch + Lomb PureVision®2 HD (high definition) soft contact lenses and Ciba Vision Air Optix Aqua soft contact lenses when used among currently adapted soft contact lens wearers.

Studienübersicht

Studientyp

Interventionell

Einschreibung (Tatsächlich)

216

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • New York
      • Rochester, New York, Vereinigte Staaten, 14609
        • Bausch & Lomb Incorporated

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Have physiologically normal anterior segments not exhibiting clinically significant biomicroscopy findings.
  • Be adapted wearers of soft contact lenses, wear a lens in each eye, and each lens must be of the same manufacture and brand.
  • Be correctable through spherocylindrical refraction to 32 letters (0.3 logMAR) or better (distance, high contrast) in each eye.
  • Be myopic and require lens correction from -0.50 diopters (D) to -6.00 D in each eye.
  • Must agree to wear the study lenses on a daily wear basis for the duration of the study.
  • Must be willing to use a lens care system on a regular basis.
  • If the subject requires a Washout Period, the subject must be willing to discontinue contact lens wear and be willing to wear either spectacles or no lenses during this Washout Period.

Exclusion Criteria:

  • Not correctable to 32 letters (0.3 logMAR) in each eye with soft spherical contact lenses.
  • Have an active ocular disease, any corneal infiltrative response or are using any ocular medications.
  • Have worn gas permeable (GP) contact lenses within last 30 days or PMMA lenses within last 3 months.
  • Any scar or neovascularization within the central 4mm of the cornea.
  • Any Grade 2 or greater finding during the slit lamp examination, Subjects with corneal infiltrates, of ANY GRADE, are not eligible.
  • Any "Present" finding during the slit lamp examination that, in the Investigator's judgment, interferes with contact lens wear.
  • Anisometropia (spherical equivalent) of greater than 2.00 D.
  • Any systemic disease affecting ocular health.
  • Using any systemic or topical medications that will affect ocular physiology or lens performance.
  • Aphakic.
  • Amblyopic.
  • Allergic to any component in the study products.
  • Have had any corneal surgery (ie, refractive surgery).
  • Currently wear monovision correction, multifocal, or toric contact lenses.
  • Ocular astigmatism greater than 1.00 D in either eye.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Single

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: B&L RD2135-01 lens C
Investigational Silicone hydrogel soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
Experimental: B&L RD2135-01 lens D
Investigational Silicone hydrogel soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
Aktiver Komparator: PureVision2
Bausch & Lomb High definition soft contact lenses
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
Aktiver Komparator: Ciba Vision Air Optix Aqua
Ciba Vision Air Optix Aqua soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Sehschärfe
Zeitfenster: Nach 1 Woche Follow-up
Die Sehschärfe wurde durch den Distanz-Hochkontrast-Logarithmus des minimalen Auflösungswinkels (logMAR) bewertet.
Nach 1 Woche Follow-up

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Symptoms and Complaints
Zeitfenster: At 1 Week follow up
Symptoms/complaints were assessed on a scale from 0 to 100, with 0 denoting unfavorable symptoms/complaints. Symptoms/complaints were recorded for each eye based on the participant's experience with their study lenses worn for that respective treatment period. Symptoms/complaints parameters included the following: Burning/stinging upon insertion, Comfort upon insertion, Overall comfort, Comfort at end of day, Ease of handling/insertion, Ease of handling/removal, Dryness, Itchiness, Redness, Vision upon insertion, Vision, Vision in low light, Lens cleanness upon insertion, Lens cleanness upon removal, Lens cleanness, Dryness at end of day, and Overall impression.
At 1 Week follow up

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn

1. April 2012

Primärer Abschluss (Tatsächlich)

1. Juni 2012

Studienabschluss (Tatsächlich)

1. Juli 2012

Studienanmeldedaten

Zuerst eingereicht

23. April 2012

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

23. April 2012

Zuerst gepostet (Schätzen)

24. April 2012

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

22. Oktober 2020

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

29. September 2020

Zuletzt verifiziert

1. September 2020

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Zusätzliche relevante MeSH-Bedingungen

Andere Studien-ID-Nummern

  • 755E

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur B&L RD2135-01 lens C

3
Abonnieren