Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

A Study to Evaluate the Product Feasibility of Two New Silicone Hydrogel Contact Lenses

29 settembre 2020 aggiornato da: Bausch & Lomb Incorporated
The objective of this study is to determine the clinical feasibility and to evaluate the product performance of two RD2135-01 investigational soft contact lenses (Test 1 and Test 2) developed by Bausch + Lomb. The Test lenses will be compared to both Bausch + Lomb PureVision®2 HD (high definition) soft contact lenses and Ciba Vision Air Optix Aqua soft contact lenses when used among currently adapted soft contact lens wearers.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Effettivo)

216

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • New York
      • Rochester, New York, Stati Uniti, 14609
        • Bausch & Lomb Incorporated

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Have physiologically normal anterior segments not exhibiting clinically significant biomicroscopy findings.
  • Be adapted wearers of soft contact lenses, wear a lens in each eye, and each lens must be of the same manufacture and brand.
  • Be correctable through spherocylindrical refraction to 32 letters (0.3 logMAR) or better (distance, high contrast) in each eye.
  • Be myopic and require lens correction from -0.50 diopters (D) to -6.00 D in each eye.
  • Must agree to wear the study lenses on a daily wear basis for the duration of the study.
  • Must be willing to use a lens care system on a regular basis.
  • If the subject requires a Washout Period, the subject must be willing to discontinue contact lens wear and be willing to wear either spectacles or no lenses during this Washout Period.

Exclusion Criteria:

  • Not correctable to 32 letters (0.3 logMAR) in each eye with soft spherical contact lenses.
  • Have an active ocular disease, any corneal infiltrative response or are using any ocular medications.
  • Have worn gas permeable (GP) contact lenses within last 30 days or PMMA lenses within last 3 months.
  • Any scar or neovascularization within the central 4mm of the cornea.
  • Any Grade 2 or greater finding during the slit lamp examination, Subjects with corneal infiltrates, of ANY GRADE, are not eligible.
  • Any "Present" finding during the slit lamp examination that, in the Investigator's judgment, interferes with contact lens wear.
  • Anisometropia (spherical equivalent) of greater than 2.00 D.
  • Any systemic disease affecting ocular health.
  • Using any systemic or topical medications that will affect ocular physiology or lens performance.
  • Aphakic.
  • Amblyopic.
  • Allergic to any component in the study products.
  • Have had any corneal surgery (ie, refractive surgery).
  • Currently wear monovision correction, multifocal, or toric contact lenses.
  • Ocular astigmatism greater than 1.00 D in either eye.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione incrociata
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: B&L RD2135-01 lens C
Investigational Silicone hydrogel soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
Sperimentale: B&L RD2135-01 lens D
Investigational Silicone hydrogel soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
Comparatore attivo: PureVision2
Bausch & Lomb High definition soft contact lenses
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.
Comparatore attivo: Ciba Vision Air Optix Aqua
Ciba Vision Air Optix Aqua soft contact lens
Lenses will be worn on a daily wear basis for 1 week. Lens care solution and lens cases will be provided for daily rinsing, cleaning, disinfecting, and storing the lenses. Rewetting drops will be provided for use as needed during the study.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Acuità visiva
Lasso di tempo: A 1 settimana di follow-up
L'acuità visiva è stata valutata dal logaritmo ad alto contrasto della distanza dell'angolo minimo di risoluzione (logMAR).
A 1 settimana di follow-up

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Symptoms and Complaints
Lasso di tempo: At 1 Week follow up
Symptoms/complaints were assessed on a scale from 0 to 100, with 0 denoting unfavorable symptoms/complaints. Symptoms/complaints were recorded for each eye based on the participant's experience with their study lenses worn for that respective treatment period. Symptoms/complaints parameters included the following: Burning/stinging upon insertion, Comfort upon insertion, Overall comfort, Comfort at end of day, Ease of handling/insertion, Ease of handling/removal, Dryness, Itchiness, Redness, Vision upon insertion, Vision, Vision in low light, Lens cleanness upon insertion, Lens cleanness upon removal, Lens cleanness, Dryness at end of day, and Overall impression.
At 1 Week follow up

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 aprile 2012

Completamento primario (Effettivo)

1 giugno 2012

Completamento dello studio (Effettivo)

1 luglio 2012

Date di iscrizione allo studio

Primo inviato

23 aprile 2012

Primo inviato che soddisfa i criteri di controllo qualità

23 aprile 2012

Primo Inserito (Stima)

24 aprile 2012

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

22 ottobre 2020

Ultimo aggiornamento inviato che soddisfa i criteri QC

29 settembre 2020

Ultimo verificato

1 settembre 2020

Maggiori informazioni

Termini relativi a questo studio

Termini MeSH pertinenti aggiuntivi

Altri numeri di identificazione dello studio

  • 755E

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su B&L RD2135-01 lens C

Sottoscrivi