Pascal Pascal Dynamic Contour Tonometer (DCT) Intraocular Pressure and Ocular Pulse Amplitude in Patients With Thyroid Related Orbitopathy: A Comparison to Goldmann Tonometer and to Muscles Characteristics on CT Scan
Pascal Dynamic Contour Tonometer Intraocular Pressure and Ocular Pulse Amplitude in Patients With Thyroid Related Orbitopathy: A Comparison to Goldmann Tonometer and to Muscles Characteristics on Orbital CT Scan
Thyroid related orbitopathy (TRO) is an autoimmune disease. Clinical features include: orbital pressure pain, ocular soft tissue swelling, muscle enlargement around the eyeball, eyelid retraction and bulging of the eye anteriorly out of the orbit. In many cases, the cornea may become too dry, and as a result, corneal ulcers may form, which can become infected. In severe cases, damage to the optic nerve can occur secondary to optic nerve compression by enlarged muscles in the orbit.
Inflammation with soft tissue swelling occurs in the 1st stage of the disease. Scar formation can occur in the 2nd phase. The muscles under and nasal to the eyeball are most commonly involved. In many patients, intra-ocular pressure (IOP) can increase in primary. IOP in upgaze (when looking up) can increase.
Goldmann applanation is the standard device to measure the IOP. It measures the average IOP (between the "systolic", when the heart contracts, to the diastolic IOP, when the heart relaxes). Pascal Dynamic Contour Tonometer is a new device that can measure IOP and ocular pulse amplitude (OPA) which is the difference between diastolic IOP and systolic IOP. The choroid is a vascular layer inside the eyeball that feeds part of the retina (the retina is like the film in a non-digital camera). OPA is suggestive of choroidal blood flow. IOP measurements using Pascal Dynamic Contour Tonometer are less influenced by corneal thickness as opposed to Goldmann applanation which measures higher values in thicker corneas. In the current study we are interested in measuring the relationships between measurements taken with Goldmann applanation (IOP) and those taken with the Pascal Dynamic Contour Tonometer (IOP and OPA). In addition, we will investigate the effect of orbital muscle enlargement on IOP/OPA following an up gaze position (looking up).
Study Overview
Status
Conditions
Study Type
Enrollment (Anticipated)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Tel-Hashomer, Ramat-Gan, Israel, 52621
- Recruiting
- Goldschleger Eye Institute, Sheba Medical Center
-
Contact:
- Ehud Rechtman, MD
- Phone Number: 972-52-2528871
- Email: ehudrechtman@gmail.com
-
Principal Investigator:
- Ehud Rechtman, MD
-
Principal Investigator:
- Guy Ben-Simon, MD
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- age > 18 yr
- agree to participate in the study and willing to sign an informed consent
Exclusion Criteria:
- other ocular diseases (besides cataract and mild hypertensive retinopathy)
- previous history of eye surgery besides cataract extraction and Nd:YAG laser capsulotomy
- moderate to severe cataract that precludes fundus examination
- pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: A
To measure the IOP (with Goldmann and Pascal DCT tonometers) and OPA (with Pascal DCT) in primary and upright gazes
|
Pascal Dynamic Contour Tonometer Goldmann Applanation Tonometer
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
IOP in primary and upright gazes measured by Goldmann and Pascal Dynamic Contour tonometers.
Time Frame: one visit
|
one visit
|
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
The change in IOP & OPA as measured by Pascal Dynamic Contour Tonometer following an upright gaze
Time Frame: one time
|
one time
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start
Primary Completion (Anticipated)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Estimate)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
- SHEBA-08-5058-ER-CTIL
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.