Prospective Multicenter Study for the Endovascular Treatment of Iliac Aneurysm With the Branched E-liac Stent Graft (TAILOR)

February 12, 2026 updated by: JOTEC GmbH

In this study, patients will be observed who receive an E-liac Stent Graft for treatment of isolated iliac aneurysms or an E-liac Stent Graft in combination with one of the following AAA stent grafts: E-tegra Stent Graft, Endurant AAA Stent Graft, Zenith AAA Endovascular Graft, Gore Excluder AAA Endoprosthesis for treatment of aorto-iliac aneurysms.

Objectives of this post-market registry are:

Primary: To prevent the risk of rupture and death by the treatment of common iliac aneurysm with an iliac branched stent graft (E-liac, JOTEC) Secondary: Evaluation of safety and feasibility of the E-liac Stent Graft System used in endovascular treatment of uni- or bilateral aorto-iliac or iliac aneurysm.

Study Overview

Status

Completed

Conditions

Study Type

Observational

Enrollment (Actual)

71

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Nantes, France
        • CHU Nantes
      • Rennes, France
        • CHU Rennes

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

19 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Sampling Method

Non-Probability Sample

Study Population

Male and female patients with unilateral or bilateral common iliac aneurysm, treated with the E-liac Stent Graft System

Description

Inclusion Criteria:

  • Unilateral or bilateral aorto-iliac or iliac aneurysm
  • Suitable for endovascular repair
  • Patient must be compliant with life- long follow-up investigations
  • >18 years old
  • lliac/femoral access vessel morphology compatible with the implantation procedure and the 18Fr (6mm OD) delivery system
  • Non-aneurysmal common iliac artery landing area in case of iliac artery aneurysm ≥ 20mm
  • Diameter of the common iliac artery in the proximal landing area: 12mm to 17mm
  • Non-aneurysmal external iliac artery segment distal to the aneurysm ≥15mm
  • Diameter of the external iliac artery in the distal landing area: 8mm to 13mm
  • Non-aneurysmal internal iliac artery segment distal to the aneurysm ≥15mm
  • Angle between external iliac artery and internal iliac artery ≤50°
  • Thrombus free iliac lumen in the area of iliac bifurcation to open hypogastric side branch and to implant covered stent ≥18mm
  • Sufficiently open internal iliac arterv ostium
  • Patients must comply with the instructions for use.
  • Patients with common iliac aneurysm with a diameter ≥30mm when isolated or common iliac aneurysm with a diameter >25mm when associated with an abdominal aortic aneurysm
  • Unilateral or bilateral common iliac aneurysm
  • Patient's anatomy must be fit for stent graft placement on preoperative angio CT scan.
  • Patient is affiliated to the social security or equivalent system.
  • The patient must be available for the appropriate follow-up times for the duration of the study.
  • Patient has been informed of the nature of the study, agrees to its provisions and has signed the informed consent from.

Exclusion Criteria:

  • Patients who do not meet the instructions for use
  • Patients with one of the contraindications as indicated in the instructions for use
  • Patients with a stenotic internal iliac ostium of < 4mm in Diameter
  • Patients with severe internal iliac atherosclerosis
  • Patients that do not have a suitable landing area in the main stem of the IIA (maximum diameter in landing area <12mm)
  • Patients with pseudoaneurysms
  • Patients with symptomatic and ruptured iliac aneurysms
  • Patients pretreated with a AAA stent graft or a bifurcated vascular graft
  • Patient with thrombocytopenia
  • Patient with an estimated glomerular filtration rate < 30 ml/min/1,73m2 immediately before the Intervention
  • Female of child bearing potential
  • In the lnvestigator's opinion patient has (a) eo-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements, or impact the scientific integrity of the study
  • Patient is currently participating in an investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints
  • Patient with malignancy needing chemotherapy or radiation
  • Patients with life expectancy of less than 36 months
  • Patient minor or under guardianship

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Clinical success
Time Frame: 30 days follow-up

Clinical success related to the E-liac Stent Graft combines the following criteria (adapted from Chaikof 2002):

  • Clinical success should be reported on an intent-to-treat Basis
  • requires successful deployment of the E-liac Stent Graft at the intended location without
  • Death as a result of iliac aneurysm-related treatment
  • Type I or III endoleak
  • E-liac Stent Graft infection
  • E-liac Stent Graft thrombosis (including internal iliac artery thrombosis)
  • Aneurysm growth >3mm in maximum diameter for common iliac aneurysm and >5mm in maximum diameter for aortic aneurysm at 12, 24, and 36 months follow-up
  • Common iliac aneurysm rupture
  • Conversion to open repair
  • Failure of E-liac Stent Graft integrity
30 days follow-up

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Adrien Kaladji, Prof., CHU Rennes

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

May 1, 2016

Primary Completion (Actual)

July 5, 2024

Study Completion (Actual)

July 5, 2024

Study Registration Dates

First Submitted

February 23, 2016

First Submitted That Met QC Criteria

February 23, 2016

First Posted (Estimated)

February 26, 2016

Study Record Updates

Last Update Posted (Actual)

February 17, 2026

Last Update Submitted That Met QC Criteria

February 12, 2026

Last Verified

February 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • TAILOR

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe