Validation of PET-MRI for Cardiovascular Disease

May 20, 2024 updated by: University of Edinburgh
To determine whether PET-MRI can obtain comparable images to PET-CT in those with coronary artery disease.

Study Overview

Detailed Description

Positron emission tomography (PET) is method of non-invasively imaging a metabolic process. It has been used in clinical medicine for many years with its primary use in identifying areas of increased metabolic activity as possible cancers. It involves the use of a radionuclide (or radiotracer) labelled to a chemical involved in a certain metabolic process. In order for the PET signal from the radiotracer to be detected by the scanner the radionuclide emits a small dose of ionizing radiation. Examples of commonly used radionuclides include 18FDG and 18 Sodium Fluoride (18NaF). In order to locate where exactly these areas of abnormal or increased metabolic activity were, Computerised Tomography (CT) has traditionally been used for anatomical correlation.

Until recently PET-CT has largely been confined for use in oncology. More recently however PET-CT has been utilized to detect vulnerable plaques in those with coronary artery disease. In coronary artery disease 18F-fluoride acts as a marker of novel calcification activity within the plaque. Similar to other conditions, calcification in coronary atheroma occurs as a healing response to intense necrotic inflammation, making 18F- fluoride a useful marker of high-risk atherosclerotic plaque. This has been demonstrated in those with stable angina as well as localizing the culprit plaque in those with myocardial infarction in 90% of cases.

Magnetic resonance imaging is being increasingly adopted in cardiovascular imaging and holds particular attraction due to its ability to provide information about soft tissue structures both with and without contrast agents, as well as its safety due to absence of exposure to ionising radiation and rapid imaging speed, which is useful in a moving organ like the heart.

PET-MR works differently to PET-CT. PET relies on the annihilation of protons with electrons, generating 511 keV photons, which are absorbed in bodily tissues differently depending on their electron density (e.g. heart denser than lungs). Because of this PET images can appear brighter or darker in different tissues. To account for this, a technique of attenuation correction is employed. This is usually in the form of what is called a transmission scan (low intensity CT scan) which grades tissue density and corrects the PET signal accordingly. Given MRI measures proton density and not electron density different attenuation correction techniques are needed. It has not yet been established how best to do this despite multiple efforts using differing techniques.

Previous single centre studies have demonstrated the feasibility of MRI-PET. The technique's translation to clinical practice has been limited due to the global lack of reliable attenuation correction methods. During his recent Clinical Research Imaging Fellowship in New York, co-investigator (Dr Dweck) developed a novel free breathing method of attenuation correction in a combined PET-MR scanner that reduced scanning time and improved efficiency and has shown immense promise. In Edinburgh a similar combined PET-MR scanner (mMR, Siemens, Erlangen, Germany) has been installed, but have not yet replicated or validated this technique. If the investigators can demonstrate and apply a method of attenuation correction that is acceptable and shows good comparability of MRI-PET to PET-CT images they may be able to use this imaging method as an alternative to PET-CT.

Benefits which may translate clinically include superior soft tissue characterisation and significantly reduced radiation dosages. The technique could be applied across a range of medical conditions in addition to cardiovascular disease and oncology.

The investigators are hopeful to establish a suitable attenuation correction method so that PET-MR can match or even supersede PET-CT as an imaging technique providing accurate biological, anatomical and functional information in those with cardiovascular disease with low radiation doses.

Study Type

Interventional

Enrollment (Actual)

20

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Lothian
      • Edinburgh, Lothian, United Kingdom, EH16 4SB
        • University of Edinburgh

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

50 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Patients undergoing thoracic PET-CT scans (this can include NHS and patients enrolled in other research studies)
  • Aged over 50 years old. No upper age limit
  • Provision of informed consent prior to any study specific procedures

Exclusion Criteria:

  • Inability or unwilling to give informed consent.
  • Major intercurrent illness with life-expectancy <2 years.
  • Contra-indication to Magnetic resonance imaging.
  • Permanent or persistent atrial fibrillation.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: PET/MR
Participants to have PET/MR scan
Patients to undergo PET/MR scanning after PET/CT scan. Patients will have had an injection of 18F Sodium Fluoride for their PET/CT therefore will not need another dose of radiotracer prior to their PET/MR scan.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
The standard uptake values (SUV's) of volumes of interest (VOI's) on corresponding PET-CT and PET-MR images will be evaluated by expert. The distribution of PET positive VOI's will be compared using a cut-off of 1.6 for tissue to background ratio (TBR).
Time Frame: 7 months
7 months

Secondary Outcome Measures

Outcome Measure
Time Frame
Standard breath-held MR-based attenuation correction will be compared to a novel free-breathing approach. Impact on PET image artifacts and the interpretation of vascular uptake will be evaluated semi-quantitatively by expert readers.
Time Frame: 7 months
7 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

February 9, 2017

Primary Completion (Actual)

December 7, 2017

Study Completion (Actual)

December 7, 2017

Study Registration Dates

First Submitted

September 23, 2016

First Submitted That Met QC Criteria

December 6, 2016

First Posted (Estimated)

December 9, 2016

Study Record Updates

Last Update Posted (Actual)

May 21, 2024

Last Update Submitted That Met QC Criteria

May 20, 2024

Last Verified

October 1, 2017

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

No plans to share patient specific data

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.