HEMolysis in a Percutaneous Axial Flow LVAD, Effects of Pentoxifylline in a Randomized Controlled Trial
HEMolysis in a Percutaneous Axial Flow Left Ventricular Assist Device, Effects of Pentoxifylline in a Randomized Controlled Trial
Temporary mechanical circulatory support devices are increasingly used for short-term support in patients with decompensated cardiogenic shock. Recently, a new axial flow pump has become widely available with the Impella System. The Impella has been FDA approved for short term usage. Hemolysis, however, has been a common complication that has increased morbidity and mortality in this patient population.
It is hypothesized that a major source of hemolysis in this patient population is shear stress experienced by red blood cells (RBC) as they travel through the pump device. In addition to causing RBC loss and potential anemia, the hemolysis has multiple other downstream consequences including creation of a pro-thrombotic environment leading to clot formation and potential device failure and secondary end organ dysfunction (renal and liver failure). Due to the significant effects of hemolysis in this population, a great deal of interest has been recently focused on addressing this problem, but as of yet no durable solutions exist.
Pentoxifylline improves red blood cell deformability and reduces blood viscosity. It is hypothesized here that administering Pentoxifylline to patients in CS who require temporary MCS will decrease the amount of shear stress related hemolysis through the improved deformability and durability of RBCs. We propose to perform a double-blinded randomized controlled trial in patients who undergo an axillary Impella 5.0 insertion for acute decompensated heart failure. There will be a control group who receives a placebo and the treatment group who receives pentoxifylline. Labs will be drawn to monitor hemolysis which is our current standard protocol for the life of the device to determine the efficacy of pentoxifylline in decreasing hemolysis in this patient population.
Study Overview
Status
Intervention / Treatment
Detailed Description
Study Type
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
California
-
Los Angeles, California, United States, 90048
- Cedars-Sinai Medical Center
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age >/= 18 years of age
- Heart failure patients who undergo axillary Impella 5.0 or 5.5 insertion for acute decompensated heart failure
Exclusion Criteria:
- Concomitant temporary mechanical circulatory support (ECMO, RVAD)
- Heparin induced thrombocytopenia
- Recent cerebral and/or retinal hemorrhage or in patients who have
- Previous intolerance to Pentoxifylline or methylxanthines such as caffeine, theophylline, and theobromine
- Women who are currently pregnant, nursing or planning on becoming pregnant.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Quadruple
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Pentoxifylline Arm
Pentoxifylline (in suspension with SyrSpend SF)
|
Blinded Pentoxifylline (in suspension with SyrSpend SF)
|
|
Placebo Comparator: Placebo Arm
Placebo (SyrSpend SF only)
|
Placebo (SyrSpend SF only)
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Reduction in REBC hemolysis
Time Frame: Up to 30 Days post-device implant
|
Measured by change in plasma free hemoglobin and lactate dehydrogenase levels
|
Up to 30 Days post-device implant
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
hemolysis requiring adjustment of device speed settings
Time Frame: Up to 30 Days post-device implant
|
Measured by change in plasma free hemoglobin and lactate dehydrogenase levels
|
Up to 30 Days post-device implant
|
|
device malfunction
Time Frame: Up to 30 Days post-device implant
|
Impella system malfunction requiring intervention or device replacement
|
Up to 30 Days post-device implant
|
|
duration of Impella support
Time Frame: Up to 30 Days post-device implant
|
Hours/days of Impella use
|
Up to 30 Days post-device implant
|
|
bleeding
Time Frame: Up to 30 Days post-device implant
|
As assessed by drop in blood count
|
Up to 30 Days post-device implant
|
|
infection
Time Frame: Up to 30 Days post-device implant
|
Assessed by fever and changes in laboratory assessments
|
Up to 30 Days post-device implant
|
|
death
Time Frame: Up to 30 Days post-device implant
|
morbidity from all causes
|
Up to 30 Days post-device implant
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Domininc Emerson, MD, Cedars-Sinai Medical Center; Smidt Heart Institute
Publications and helpful links
General Publications
- Lima B, Kale P, Gonzalez-Stawinski GV, Kuiper JJ, Carey S, Hall SA. Effectiveness and Safety of the Impella 5.0 as a Bridge to Cardiac Transplantation or Durable Left Ventricular Assist Device. Am J Cardiol. 2016 May 15;117(10):1622-1628. doi: 10.1016/j.amjcard.2016.02.038. Epub 2016 Mar 4.
- Katz JN, Jensen BC, Chang PP, Myers SL, Pagani FD, Kirklin JK. A multicenter analysis of clinical hemolysis in patients supported with durable, long-term left ventricular assist device therapy. J Heart Lung Transplant. 2015 May;34(5):701-9. doi: 10.1016/j.healun.2014.10.002. Epub 2014 Nov 4.
- Badiye AP, Hernandez GA, Novoa I, Chaparro SV. Incidence of Hemolysis in Patients with Cardiogenic Shock Treated with Impella Percutaneous Left Ventricular Assist Device. ASAIO J. 2016 Jan-Feb;62(1):11-4. doi: 10.1097/MAT.0000000000000290.
- Ravichandran AK, Parker J, Novak E, Joseph SM, Schilling JD, Ewald GA, Silvestry S. Hemolysis in left ventricular assist device: a retrospective analysis of outcomes. J Heart Lung Transplant. 2014 Jan;33(1):44-50. doi: 10.1016/j.healun.2013.08.019. Epub 2013 Nov 14.
- Nielsen VG, Pearson EC, Smith MC. Increased carbon monoxide production by hemeoxygenase-1 caused by device-mediated hemolysis: thrombotic phantom menace? Artif Organs. 2013 Nov;37(11):1008-14. doi: 10.1111/aor.12122. Epub 2013 Jul 19.
- Jennings DL, Williams CT, Morgan JA. Pentoxifylline for the treatment of hemolytic anemia in a patient who developed recurrent gastrointestinal bleeding while on continuous-flow left ventricular assist device support. ASAIO J. 2013 Sep-Oct;59(5):526-7. doi: 10.1097/MAT.0b013e31829f0eb1.
- Polonini HC, Silva SL, de Almeida TR, Brandao MAF, Ferreira AO. Compatibility of caffeine, carvedilol, clomipramine hydrochloride, folic acid, hydrochlorothiazide, loperamide hydrochloride, methotrexate, nadolol, naltrexone hydrochloride and pentoxifylline in SyrSpend SF PH4 oral suspensions. Eur J Hosp Pharm. 2016 Nov;23(6):352-358. doi: 10.1136/ejhpharm-2016-000903. Epub 2016 Mar 24.
- Bansal A, Bhama JK, Patel R, Desai S, Mandras SA, Patel H, Collins T, Reilly JP, Ventura HO, Parrino PE. Using the Minimally Invasive Impella 5.0 via the Right Subclavian Artery Cutdown for Acute on Chronic Decompensated Heart Failure as a Bridge to Decision. Ochsner J. 2016 Fall;16(3):210-6.
Study record dates
Study Major Dates
Study Start (Estimated)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Pathologic Processes
- Hemolysis
- Physiological Effects of Drugs
- Molecular Mechanisms of Pharmacological Action
- Enzyme Inhibitors
- Platelet Aggregation Inhibitors
- Antioxidants
- Protective Agents
- Free Radical Scavengers
- Vasodilator Agents
- Phosphodiesterase Inhibitors
- Radiation-Protective Agents
- Pentoxifylline
Other Study ID Numbers
- CSMC - STUDY00000179
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.