Existing Evidence on Ultrasound-Guided Injections in Sports Medicine

Eldra W Daniels, David Cole, Bret Jacobs, Shawn F Phillips, Eldra W Daniels, David Cole, Bret Jacobs, Shawn F Phillips

Abstract

Office-based ultrasonography has become increasingly available in many settings, and its use to guide joint and soft tissue injections has increased. Numerous studies have been conducted to evaluate the use of ultrasound-guided injections over traditional landmark-guided injections, with a rapid growth in the literature over the past few years. A comprehensive review of the literature was conducted to demonstrate increased accuracy of ultrasound-guided injections regardless of anatomic location. In the upper extremity, ultrasound-guided injections have been shown to provide superior benefit to landmark-guided injections at the glenohumeral joint, the subacromial space, the biceps tendon sheath, and the joints of the hand and wrist. Ultrasound-guided injections of the acromioclavicular and the elbow joints have not been shown to be more efficacious. In the lower extremity, ultrasound-guided injections at the knee, ankle, and foot have superior efficacy to landmark-guided injections. Conclusive evidence is not available regarding improved efficacy of ultrasound-guided injections of the hip, although landmark-guided injection is performed less commonly at the hip joint. Ultrasound-guided injections are overall more accurate than landmark-guided injections. While current studies indicate that ultrasound guidance improves efficacy and cost-effectiveness of many injections, these studies are limited and more research is needed.

Keywords: joint injection; musculoskeletal ultrasonography; osteoarthritis; sports medicine; tendinopathy; ultrasound-guided injection.

Conflict of interest statement

The authors declared that they have no conflicts of interest in the authorship and publication of this contribution.

References

    1. Adler RS, Buly R, Ambrose R, Sculco T. Diagnostic and therapeutic use of sonography-guided iliopsoas peritendinous injections. AJR Am J Roentgenol. 2005;185:940–943.
    1. Aly AR, Rajasekkaran S, Ashworth N. Ultrasound-guided shoulder girdle injections are more accurate and more effective than landmark-guided injections: a systematic review and meta-analysis. Br J Sport Med. 2015;49:1042–1049.
    1. Bellamy N, Campbell J, Robinson V, et al. Intraarticular corticosteroid for treatment of osteoarthritis of the knee. Cochrane Database Syst Rev. 2006;(2):CD005382.
    1. Berkoff DJ, Miller LE, Block JE. Clinical utility of ultrasound guidance for intra-articular knee injections: a review. Clin Interv Aging. 2012;7:89–95.
    1. Blankebaker DG, De Smet AA, Kee JS. Sonography of the iliopsoas tendon and injection of the iliopsoas bursa for the diagnosis and management of the painful snapping hip. Skeletal Radiol. 2006;35(8):565–571.
    1. Bloom JE, Rischin A, Johnston RV, et al. Image-guided versus blind glucocorticoid injection for shoulder pain. Cochrane Database Syst Rev. 2012;(8):CD009147.
    1. Borbas P, Kraus T, Clement H, et al. The influence of ultrasound guidance in the rate of success of acromioclavicular joint injection: an experimental study on human cadavers. J Shoulder Elbow Surg. 2012;21:1694–1697.
    1. Chen MJ, Lew HL, Hsu TC, et al. Ultrasound-guided shoulder injections in the treatment of subacromial bursitis. Am J Phys Med Rehabil. 2006;85:31–35.
    1. Cunnington J, Marshall N, Hide G, et al. A randomized, double-blind, controlled study of ultrasound-guided corticosteroid injection into the joint of patients with inflammatory arthritis. Arthritis Rheum. 2010;62:1862–1869.
    1. Curtiss HM, Finnoff JT, Peck E, et al. Accuracy of ultrasound-guided and palpation-guided knee injections by an experienced and less-experienced injector using a superolateral approach: a cadaveric study. PM R. 2011;3:507–515.
    1. Daley EL, Bajaj S, Bisson LJ, et al. Improving injection accuracy of the elbow, knee, and shoulder: does injection site and imaging make a difference? A systematic review. Am J Sports Med. 2011;39:656–662.
    1. Diracoglu D, Alptekin K, Dikici F, et al. Evaluation of needle positioning during blind intra-articular hip injections for osteoarthritis: fluoroscopy versus arthrography. Arch Phys Med Rehabil. 2009;90:2112–2115.
    1. Drakonaki EE, Kho JS, Sharp RJ, et al. Efficacy of ultrasound guided steroid injections for pain management of midfoot joint degenerative disease. Skeletal Radiol. 2011;40:1001–1006.
    1. Dussik KT, Fritch DJ, Kyriazidou M, et al. Measurements of articular tissues with ultrasound. Am J Phys Med. 1958;37:160–165.
    1. Esenyel C, Demirhan M, Esenyel M, et al. Comparison of four different intra-articular injection sites in the knee: a cadaver study. Knee Surg Sports Traumatol Arthrosc. 2007;15:573–577.
    1. Finnoff JT, Berkoff D, Brennan F, et al. American Medical Society for Sports Medicine recommended sports ultrasound curriculum for sports medicine fellowships. Clin J Sport Med. 2015;25:23–29.
    1. Finnoff JT, Hall MM, Adams E, et al. American Medical Society for Sports Medicine position statement: interventional musculoskeletal ultrasound in sports medicine. Clin J Sport Med. 2015;25:6–22.
    1. Goncalves B, Ambrosio C, Serra S, et al. US-guided interventional joint procedures in patients with rheumatic diseases—when and how we do it? Eur J Radiol. 2011;79:407–414.
    1. Hall MM. The accuracy and efficacy of palpation versus image-guided peripheral injections in sports medicine. Curr Sports Med Rep. 2013;12:296–303.
    1. Hashiuchi T, Sakurai G, Morimoto M, et al. Accuracy of the biceps tendon sheath injection: ultrasound-guided or unguided injection? A randomized controlled trial. J Shoulder Elbow Surg. 2011;20:1069–1673.
    1. Hermans J, Bierma-Zeinstra SM, Bos PK, et al. The most accurate approach for intra-articular needle placement in the knee joint: a systematic review. Semin Arthritis Rheum. 2011;41:106–115.
    1. Jackson DW, Evans NA, Thomas BM. Accuracy of needle placement into the intra-articular space of the knee. J Bone Joint Surg Am. 2002;84-A:1522–1527.
    1. Khosla S, Thiele R, Baumhauer JF. Ultrasound guidance for intra-articular injections of the foot and ankle. Foot Ankle Int. 2009;30:886–890.
    1. Lee HJ, Lim KB, Kim DY, et al. Randomized controlled trial for efficacy of intra-articular injection for adhesive capsulitis: ultrasonography-guided versus blind technique. Arch Phys Med Rehabil. 2009;90:1997–2002.
    1. Levi DS. Intra-articular hip injections using ultrasound guidance: accuracy using a linear array transducer. PM R. 2013;5:129–134.
    1. Lopes RV, Furtado RN, Parmigiani L, et al. Accuracy of intra-articular injections in peripheral joints performed blindly in patients with rheumatoid arthritis. Rheumatology (Oxford). 2008;47:1792–1794.
    1. Micu MC, Bogdan GD, Fodor D. Steroid injection for hip osteoarthritis: efficacy under ultrasound guidance. Rheumatology (Oxford). 2010;49:1490–1494.
    1. Migliore A, Granata M, Tormenta S, et al. Hip viscosupplementation under ultra-sound guidance reduces NSAID consumption in symptomatic hip osteoarthritis patients in a long follow-up: data from Italian registry. Eur Rev Med Pharmacol Sci. 2011;15:25–34.
    1. Patel DN, Nayyar S, Hasan S, et al. Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study. J Shoulder Elbow Surg. 2012;21:1664–1668.
    1. Patel Y, Scillia A, Festa A, et al. The role of ultrasound-guided injections in orthopaedic sports medicine: upper extremity. AAOS Now. January 9, 2015:14.
    1. Peck E, Lai JK, Pawlina W, et al. Accuracy of ultrasound-guided versus palpation-guided acromioclavicular joint injections: a cadaveric study. PM R. 2010;2:817–821.
    1. Pollard MA, Cermak MB, Buck WR, et al. Accuracy of injection into the basal joint of the thumb. Am J Orthop. 2007;36:204–206.
    1. Pourbagher MA, Ozalay M, Pourbagher A. Accuracy and outcome of sonographically guided intra-articular sodium hyaluronate injections in patients with osteoarthritis of the hip. J Ultrasound Med. 2005;24:1391–1395.
    1. Raza K, Lee CY, Pilling D, et al. Ultrasound guidance allows accurate needle placement and aspiration from small joints in patients with early inflammatory arthritis. Rheumatology. 2003;42:976–979.
    1. Reach JS, Easley ME, Chuckpaiwong B, et al. Accuracy of ultrasound guided injections in the foot and ankle. Foot Ankle Int. 2009;30:239–242.
    1. Rho ME, Chu SK, Yang A, et al. Resident accuracy of joint line palpation using ultrasound verification. PM R. 2014;6:920–925.
    1. Sabeti-Aschraf M, Lemmerhofer B, Lang S, et al. Ultrasound guidance improves the accuracy of the acromioclavicular joint infiltration: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc. 2011;19:292–295.
    1. Sabeti-Aschraf M, Ochsner A, Schueller-Weidekamm C, et al. The infiltration of the AC joint performed by one specialist: ultrasound versus palpation a prospective randomized pilot study. Eur J Radiol. 2010;75:e37–e40.
    1. Sibbitt WL, Jr, Band PA, Kettwich LG, et al. A randomized controlled trial evaluating the cost-effectiveness of sonographic guidance for intra-articular injection of the osteoarthritic knee. J Clin Rheumatol. 2011;17:409–415.
    1. Sibbitt WL, Jr, Kettwich LG, Band PA, et al. Does ultrasound guidance improve the outcomes of arthrocentesis and corticosteroid injection of the knee? Scand J Rheumatol. 2012;41:66–72.
    1. Silver SF, Connell DG, Duncan CP. Case report 550. Skeletal Radiol. 1989;18:327–328.
    1. Smith J, Brault JS, Rizzo M, et al. Accuracy of sonographically guided and palpation guided scaphotrapeziotrapezoid joint injections. J Ultrasound Med. 2011;30:1509–1515.
    1. Smith J, Finnoff JT, Levy BA, et al. Sonographically guided proximal tibiofibular joint injection: technique and accuracy. J Ultrasound Med. 2010;29:783–789.
    1. Smith J, Hurdle MF, Weingarten TN. Accuracy of sonographically guided intra-articular injections in the native adult hip. J Ultrasound Med. 2009;28:329–335.
    1. Smith J, Rizzo M, Sayeed YA, et al. Sonographically guided distal radioulnar joint injection: technique and validation in a cadaveric model. J Ultrasound Med. 2011;30:1587–1592.
    1. Ucuncu F, Capkin E, Karkucak M, et al. A comparison of the effectiveness of landmark-guided injections and ultrasonography guided injections for shoulder pain. Clin J Pain. 2009;25:786–789.
    1. Umphrey GL, Brault JS, Hurdle MF, et al. Ultrasound-guided intraarticular injection of the trapeziometacarpal joint: description of technique. Arch Phys Med Rehabil. 2008;89:153–156.
    1. Vaccaro JP, Sauser DD, Beals RK. Iliopsoas bursa imaging: efficacy in depicting abnormal iliopsoas tendon motion in patients with internal snapping hip syndrome. Radiology. 1995;197(3):853–856.
    1. Wahl CJ, Warren RF, Adler RS, et al. Internal coxa saltans (snapping hip) as a result of overtraining—a report of 3 cases in professional athletes with a review of causes and the role of ultrasound in early diagnosis and management. Am J Sports Med. 2004;32(5):1302–1309.
    1. Wempe MK, Sellon JL, Sayeed YA, et al. Feasibility of first metatarsophalangeal joint injections for sesamoid disorders: a cadaveric investigation. PM R. 2012;4:556–560.
    1. Wisniewski SJ, Smith J, Patterson DG, et al. Ultrasound-guided versus nonguided tibiotalar joint and sinus tarsi injections: a cadaveric study. PM R. 2010;2:277–281.
    1. Wright J, Swiontkowski MF, Heckman JD. Introducing levels of evidence to the journal. J Bone Joint Surg Am. 2003;85:1–3.
    1. Yoong P, Guirguis R, Darrah R, et al. Evaluation of ultrasound-guided diagnostic local anaesthetic hip joint injection for osteoarthritis. Skeletal Radiol. 2012;41:981–985.
    1. Zhang J, Ebraheim N, Lause GE. Ultrasound-guided injection for the biceps brachii tendinitis: results and experience. Ultrasound Med Biol. 2011;37:729–733.
    1. Ziv YB, Kardosh R, Debi R, et al. An inexpensive and accurate method for hip injections without the use of imaging. J Clin Rheumatol. 2009;15:103–105.

Source: PubMed

3
Subscribe