Diagnostic accuracy of a urine lipoarabinomannan strip-test for TB detection in HIV-infected hospitalised patients

Jonathan G Peter, Grant Theron, Richard van Zyl-Smit, Asheen Haripersad, Lynelle Mottay, Sarah Kraus, Anke Binder, Richard Meldau, Anneli Hardy, Keertan Dheda, Jonathan G Peter, Grant Theron, Richard van Zyl-Smit, Asheen Haripersad, Lynelle Mottay, Sarah Kraus, Anke Binder, Richard Meldau, Anneli Hardy, Keertan Dheda

Abstract

Lack of point-of-care tests for tuberculosis (TB) result in diagnostic delay, and increased mortality and healthcare-related costs. The urine Determine(TM) TB-LAM point-of-care strip-test was evaluated in 335 prospectively-recruited hospitalised patients with suspected TB-HIV co-infection (group 1) and from 88 HIV-infected hospitalised patients with non-TB diagnoses (group 2). Cut-off point-specific analyses were performed using: 1) a microbiological reference standard (culture positive versus negative); and 2) a composite reference standard (exclusion of patients with clinical-TB from the culture-negative group). Using the microbiological reference and the manufacturer-recommended grade-1 cut-off point, LAM sensitivity and specificity was 66% (95% CI 57-74%). By contrast, using the composite reference sensitivity was 60% (95% CI 53-67%) and specificity improved to 96% (95% CI 89-100%) (p=0.001). The same pattern was seen when the grade-2 cut-off point was used (specificity 75% versus 96%; p=0.01). In group two patients specificity was poor using the grade-1 cut-off point, but improved significantly when the grade-2 cut-off point was used (90% versus 99%; p=0.009). The grade-2 cut-off point also offered superior inter-reader reliability (p=0.002). Sensitivity was highest in those with a CD4 <200 cells per mL. LAM combined with smear-microscopy was able to rule-in TB in 71% of Mycobacterium tuberculosis culture-positive patients. This preliminary study indicates that the LAM strip-test may be a potentially useful rapid rule-in test for TB in hospitalised patients with advanced immunosuppression. The grade 2, but not the manufacturer-recommended grade 1 cut-off point, offered superior rule-in utility and inter-reader reliability. Larger studies to evaluate cut-off points and diagnostic accuracy are urgently required.

Conflict of interest statement

STATEMENT OF INTEREST

A statement of interest for the study can be found at www.erj.ersjournals.com/site/misc/statements.xhtml

Figures

FIGURE 1
FIGURE 1
Lipoarabinomannan (LAM) strip-test and reference scale card. The reference scale card (courtesy of Alere, Waltham, MA, USA) illustrates six cut-off points (visual grades 0–5) categorised by different band intensities appearing in the patient window.
FIGURE 2
FIGURE 2
Study population and outline of different patient groups used for the two analyses of urine lipoarabinomannan (LAM) strip-test diagnostic accuracy. M. tuberculosis: Mycobacterium tuberculosis; TB: tuberculosis.
FIGURE 3
FIGURE 3
Receiver operator characteristic (ROC) curves for urine lipoarabinomannan strip-test graded by two independent readers for HIV-infected patients. Sensitivity, specificity and positive likelihood ratios are shown for different visual band intensity-based cut-off points (grade 1 (manufacturer recommended) and grades 2 and 3 (optimised for “rule-in”) are indicated). a) Analysis 1 (Mycobacterium tuberculosis culture reference standard). b) Analysis 2 (composite reference standard).

Source: PubMed

3