Dispersive Transport of Angiographic Contrast During Antegrade Arterial Injection

Qing Hao, Baruch B Lieber, Qing Hao, Baruch B Lieber

Abstract

PURPOSE: Angiography is commonly used during endovascular procedures to navigate catheters into a target artery and for evaluation of the arterial luminal geometry. X-ray attenuating contrast material is injected into the arteries and transported into pathologies such as aneurysms or arteriovenous malformations. Images of the transported contrast are used to guide therapeutic decisions. Experience and intuition of the interventionalist are often serving as guide for the injection force, and hence, the speed and volume of the bolus. Forceful injections of small boluses can evoke local turbulence and dispersive mixing in the zone immediately distal to the catheter tip. Turbulence by its nature acts as a strong agitating mechanism such that the bolus of contrast quickly mixes with the flowing blood to occupy the entire lumen so the artery can be visualized. The aims of the present study are (a) to determine the distance from catheter tip beyond which contrast can consider to be fully mixed with the blood during antegrade injection and (b) to determine the thickness of the boundary layer in which contrast concentration is poor, which can contribute to underestimation of vascular diameter using this method. METHODS: We performed in silico experiments to describe blood and angiographic contrast transport in a straight artery model. The conditions investigated are derived from clinical contrast injection rates typically found in cerebral angiography. RESULTS: A recirculation flow exists in the mixing zone distal to the catheter tip issuing the contrast and convective mixing rather than diffusion is dominating the rapid mixing process. In the vicinity of the arterial wall in the mass transfer boundary layer, however, transport is dominated by molecular diffusion. For lower molecule diffusion coefficient, the mass transfer boundary layer contains a lower concentration of contrast than for a higher molecular diffusion coefficient. CONCLUSIONS: These findings imply that contrast visibility near the arterial wall is poor such that arterial dimensions derived from angiograms may be underestimated and consequently sizing of potential implants inaccurate. Outside the mass transfer boundary layer contrast can be considered as fully mixed with the carrying flow in about 10 arterial diameters distal to the injection port.

Figures

Figure 1
Figure 1
Top Panel: Schematic of the flow domain. Bottom panel: Contrast distribution in the flow domain and scale bar showing contrast concentration fraction.
Figure 2
Figure 2
Radial distribution of the mass fraction of contrast along the tube axis every 2 tube diameters distal to the injection port (A = Case #1; B = Case#2; C = Case #3). Maximum values are noted in each profile.
Figure 2
Figure 2
Radial distribution of the mass fraction of contrast along the tube axis every 2 tube diameters distal to the injection port (A = Case #1; B = Case#2; C = Case #3). Maximum values are noted in each profile.
Figure 2
Figure 2
Radial distribution of the mass fraction of contrast along the tube axis every 2 tube diameters distal to the injection port (A = Case #1; B = Case#2; C = Case #3). Maximum values are noted in each profile.
Figure 3
Figure 3
Top: Radial distribution of the velocity along the tube axis every 2 tube diameters distal to the injection port (Case #1). Bottom: close up of velocity distribution showing recirculation near the wall. Maximum values are noted in each profile.
Figure 4
Figure 4
Percent difference of the average radial contrast distribution at successive axial locations (Case #1).
Figure 5
Figure 5
Radial distribution of contrast at x=10D for different molecular diffusion coefficients (Case #3).

Source: PubMed

3
Subscribe