Clinical and Laboratory Outcomes of Angled Screw Channel Implant Prostheses: A Systematic Review

Vanya Rasaie, Jaafar Abduo, Mehran Falahchai, Vanya Rasaie, Jaafar Abduo, Mehran Falahchai

Abstract

The purpose of this systematic review was to evaluate the clinical and laboratory outcomes of angled screw channel (ASC) restorations and to summarize the influencing factors. An electronic search of the English language literature was performed in four databases and enriched by manual searches. Retrieved studies were screened against the predefined exclusion and inclusion criteria. Eight clinical and seven laboratory studies were eligible for the analysis. The risk of bias for included observational studies was performed using the Newcastle-Ottawa quality assessment scale. Laboratory studies quality assessment method was adapted from previous published systematic reviews. Two clinical studies focused on technical outcomes and the rest reported the biological outcomes of the ASC restorations. Out of the seven laboratory studies, two studies investigated the fracture resistance of ASC restorations, four studies evaluated the reverse torque value of the nonaxially tightened screws, and one study evaluated both variables. The present review revealed that while the performance of ASC restorations is promising in short-term clinical studies, the evidence of their long-term reliability is still lacking. The laboratory studies indicated comparable fracture resistance results of the ASC restorations with the straight screw channel restorations. In addition, factors, such as initial torque value, configuration of the screw driver, screw design, abutment system, and the angulation of screw channel, were shown to influence the screw resistance to loosening.

Conflict of interest statement

None declared.

The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/).

Figures

Fig. 1
Fig. 1
Flowchart for search process according to PRISMA guideline. PRISMA, preferred reporting items for systematic reviews and meta-analyses.

References

    1. Moraschini V, Poubel L A, Ferreira V F, Barboza EdosS. Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic review. Int J Oral Maxillofac Surg. 2015;44(03):377–388.
    1. Dario L J. Implant angulation and position and screw or cement retention: clinical guidelines. Implant Dent. 1996;5(02):101–104.
    1. Sailer I, Mühlemann S, Zwahlen M, Hämmerle C H, Schneider D. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res. 2012;23 06:163–201.
    1. Wittneben J G, Millen C, Brägger U.Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions–a systematic review Int J Oral Maxillofac Implants 201429(suppl):84–98.
    1. Michalakis K X, Hirayama H, Garefis P D. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants. 2003;18(05):719–728.
    1. Albrektsson T, Canullo L, Cochran D, De Bruyn H. “Peri-implantitis”: a complication of a foreign body or a man-made “disease”. Facts and fiction. Clin Implant Dent Relat Res. 2016;18(04):840–849.
    1. Millen C, Brägger U, Wittneben J G. Influence of prosthesis type and retention mechanism on complications with fixed implant-supported prostheses: a systematic review applying multivariate analyses. Int J Oral Maxillofac Implants. 2015;30(01):110–124.
    1. Cavallaro J, Jr, Greenstein G. Angled implant abutments: a practical application of available knowledge. J Am Dent Assoc. 2011;142(02):150–158.
    1. Sethi A, Sochor P. The lateral fixation screw in implant dentistry. Eur J Prosthodont Restor Dent. 2000;8(01):39–43.
    1. Berroeta E, Zabalegui I, Donovan T, Chee W. Dynamic abutment: a method of redirecting screw access for implant-supported restorations: technical details and a clinical report. J Prosthet Dent. 2015;113(06):516–519.
    1. Edmondson E K, Trejo P M, Soldatos N, Weltman R L. The ability to screw-retain single implant-supported restorations in the anterior maxilla: a CBCT analysis. J Prosthet Dent. 2021;S0022-3913(21):32–39.
    1. Wells G SB, O'Connell D, Peterson J.The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analysesAccessed January 16, 2020 at:
    1. Wang C, Shi Y F, Xie P J, Wu J H. Accuracy of digital complete dentures: a systematic review of in vitro studies. J Prosthet Dent. 2021;125(02):249–256.
    1. Rosa W L, Piva E, Silva A F. Bond strength of universal adhesives: a systematic review and meta-analysis. J Dent. 2015;43(07):765–776.
    1. Garcia-Hammaker S, Saglik B, Sierraalta M, Razzoog M. Influence of screw channel angulation on the fracture resistance of zirconia abutments: an in vitro study. J Prosthodont. 2021;30(04):329–334.
    1. Drew A, Randi A, DiPede L, Luke A. Fracture strength of implant screw-retained all-ceramic crowns with the use of the angulated screw channel: a pilot study. Int J Periodontics Restorative Dent. 2020;40(02):245–252.
    1. Swamidass R S, Kan J YK, Kattadiyil M T, Goodacre C J, Lozada J. Abutment screw torque changes with straight and angled screw-access channels. J Prosthet Dent. 2021;124(04):675–681.
    1. Opler R, Wadhwani C, Chung K H. The effect of screwdriver angle variation on the off-axis implant abutment system and hexalobular screw. J Prosthet Dent. 2020;123(03):524–528.
    1. Mulla S H, Seghi R R, Johnston W M, Yilmaz B. Effect of cyclic loading on reverse torque values of angled screw channel systems. J Prosthet Dent. 2021;S0022-3913(21):7-X. doi: 10.1016/j.prosdent.2020.12.020.
    1. Hu E, Petrich A, Imamura G, Hamlin C. Effect of screw channel angulation on reverse torque values of dental implant abutment screws. J Prosthodont. 2019;28(09):969–972.
    1. Goldberg J, Lee T, Phark J H, Chee W. Removal torque and force to failure of non-axially tightened implant abutment screws. J Prosthet Dent. 2019;121(02):322–326.
    1. Pol C WP, Raghoebar G M, Maragkou Z, Cune M S, Meijer H JA. Full-zirconia single-tooth molar implant-supported restorations with angulated screw channel abutments: a 1-year prospective case series study. Clin Implant Dent Relat Res. 2020;22(01):138–144.
    1. Greer A C, Hoyle P J, Vere J W, Wragg P F. Mechanical complications associated with angled screw channel restorations. Int J Prosthodont. 2017;30(03):258–259.
    1. Friberg B, Ahmadzai M. A prospective study on single tooth reconstructions using parallel walled implants with internal connection (NobelParallel CC) and abutments with angulated screw channels (ASC) Clin Implant Dent Relat Res. 2019;21(02):226–231.
    1. Anitua E, Flores C, Piñas L, Alkhraisat M H. Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by computer-aided design/computer-aided manufacturing. J Oral Implantol. 2018;44(06):427–431.
    1. Anitua E, Fernández-de-Retana S, Alkhraisat M H. Survival and marginal bone loss of dental implants supporting cad-cam angled channel restorations: a split-mouth retrospective study. Eur J Dent. 2020;14(02):194–199.
    1. Tallarico M, Ceruso F M, Xhanari E, Gargari M, Canullo L, Meloni S M. Immediately loaded tilted implants combined with angulated screw channel zirconia abutments in atrophic maxillary patients: a three-year after loading prospective case series study. ORAL and Implantol. 2018;11:106–114.
    1. Shi J-Y, Lv X-L, Gu Y-X, Lai H-C. Angulated screw-retained and cemented implant crowns following flapless immediate implant placement in the aesthetic region: a 1-year prospective cohort study. Int J Oral Implantol (Berl) 2020;13(03):269–277.
    1. Nastri L, Nucci L, Grassia V, Miraldi R. Aesthetic outcomes and peri-implant health of angled screw retained implant restorations compared with cement retained crowns: medium term follow-up. J Funct Biomater. 2021;12(02):12.
    1. Lin Y T, Shen Y F, Wei P C, Hsu K W. Clinical evaluation of two-piece zirconia abutments with bonded titanium inserts for implant-supported restorations. J Prosthet Dent. 2020;123(03):449–454.
    1. Aboushelib M N, Salameh Z. Zirconia implant abutment fracture: clinical case reports and precautions for use. Int J Prosthodont. 2009;22(06):616–619.
    1. Zandparsa R, Albosefi A. An in vitro comparison of fracture load of zirconia custom abutments with internal connection and different angulations and thicknesses: part II. J Prosthodont. 2016;25(02):151–155.
    1. Bickford J H. Oxford, United Kingdom: Tylor and Francis Group; 1995. An Introduction to the Design and Behavior of Bolted Joints; pp. 175–180.
    1. Torcato L B, Pellizzer E P, Verri F R, Falcón-Antenucci R M, Santiago Júnior J F, de Faria Almeida D A. Influence of parafunctional loading and prosthetic connection on stress distribution: a 3D finite element analysis. J Prosthet Dent. 2015;114(05):644–651.
    1. Hurson S.Use of authentic, integrated dental implant components vital to predictability and successful long-term clinical outcomes Compend Contin Educ Dent 20163707450–455., z456
    1. Monje A, Chan H L, Suarez F, Galindo-Moreno P, Wang H L. Marginal bone loss around tilted implants in comparison to straight implants: a meta-analysis. Int J Oral Maxillofac Implants. 2012;27(06):1576–1583.
    1. Del Fabbro M, Ceresoli V. The fate of marginal bone around axial vs. tilted implants: a systematic review. Eur J Oral Implantology. 2014;7 02:S171–S189.
    1. Chen Z, Lin C Y, Li J, Wang H L, Yu H. Influence of abutment height on peri-implant marginal bone loss: a systematic review and meta-analysis. J Prosthet Dent. 2019;122(01):14–2100.
    1. Tallarico M, Caneva M, Meloni S M, Xhanari E, Covani U, Canullo L. Definitive abutments placed at implant insertion and never removed: is it an effective approach? a systematic review and meta-analysis of randomized controlled trials. J Oral Maxillofac Surg. 2018;76(02):316–324.
    1. Anitua E, Alkhraisat M H. Clinical performance of short dental implants supporting single crown restoration in the molar-premolar region: cement versus screw retention. Int J Oral Maxillofac Implants. 2019;34(04):969–976.
    1. Chen J-Y, Pan Y-H. Zirconia implant abutments supporting single all-ceramic crowns in anterior and premolar regions: a six-year retrospective study. Biomed J. 2019;42(05):358–364.
    1. Guljé F L, Meijer H JA, Abrahamsson I. Comparison of 6-mm and 11-mm dental implants in the posterior region supporting fixed dental prostheses: 5-year results of an open multicenter randomized controlled trial. Clin Oral Implants Res. 2021;32(01):15–22.
    1. Hotinski E, Dudley J. Abutment screw loosening in angulation-correcting implants: An in vitro study. J Prosthet Dent. 2019;121(01):151–155.
    1. Menéndez-Collar M, Serrera-Figallo M A, Hita-Iglesias P. Straight and tilted implants for supporting screw-retained full-arch dental prostheses in atrophic maxillae: a 2-year prospective study. Med Oral Patol Oral Cir Bucal. 2018;23(06):e733–e741.
    1. Mokhtarpour H, Eftekhar Ashtiani R, Mahshid M, Tabatabaian F, Alikhasi M. Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study. J Dent Res Dent Clin Dent Prospect. 2016;10(03):181–188.
    1. Paolantoni G, Marenzi G, Blasi A, Mignogna J, Sammartino G. Findings of a four-year randomized controlled clinical trial comparing two-piece and one-piece zirconia abutments supporting single prosthetic restorations in maxillary anterior region. BioMed Res Int. 2016;2016:8.767845E6.
    1. Vélez J, Peláez J, López-Suárez C, Agustín-Panadero R, Tobar C, Suárez M J. Influence of implant connection, abutment design and screw insertion torque on implant-abutment misfit. J Clin Med. 2020;9(08):2365.
    1. González-Martín O, Veltri M. Immediate implant in maxillary central incisors and prosthetic screw channel: a CBCT feasibility study. Int J Periodontics Restorative Dent. 2021;41(02):245–251.
    1. Farré-Berga O, Cercadillo-Ibarguren I, Sánchez-Torres A. Novel ball head screw and screwdriver design for implant-supported prostheses with angled channels: a finite element analysis. J Oral Implantol. 2018;44(06):416–422.
    1. Farronato D, Manfredini M, Stevanello A, Campana V, Azzi L, Farronato M. A comparative 3D finite element computational study of three connections. Materials (Basel) 2019;12(19):3135.
    1. Wang J, Lerman G, Bittner N, Fan W, Lalla E, Papapanou P N. Immediate versus delayed temporization at posterior single implant sites: A randomized controlled trial. J Clin Periodontol. 2020;47(10):1281–1291.

Source: PubMed

3
Subscribe