Glidescope® Videolaryngoscope is an angulated rigid optical device introduced in clinical practice in 2004 to facilitate endotracheal intubation.
Since its introduction potential benefits of this instrument might lie with use in patients with clinical features indicating difficult laryngoscopy or it being used as a rescue method following failed direct laryngoscopy. In a few centers was proposed and used routinely.
The performance of Glidescope® was studied in easy and difficult scenarios, in vivo and on manikins and compared with the reference standard McIntosh direct laryngoscopy. In patients with predicted or simulated difficult intubation, despite glottis visualization was improved with Glidescope®, the introduction of the tube in trachea was difficult the same as with McIntosh laryngoscopy. Training of operators before to entertain the trials varied from 20 to 50 Glidescope successful intubations. In an observational study Aziz et al. demonstrated in the two Institutions involved that the GlideScope® was used more frequently at the Institution were the failure rate was significantly lower. At this , 51 providers performed mean 21.7 GlideScope® intubations while at the other 91 providers performed 9.9 intubations.
These data highlight the important issue of how many Glidescope® intubations a provider should complete to reach a definitive clinical competence in this practice. Until now there is only one study performed on mankin comparing Glidescope® with AirTraq® and McIntosh laryngoscopes in novices . The authors concluded that despite a steep learning curve after 5 intubation difficulties in instrumentation and longer times to intubate persisted with Glidescope® in comparison with the other two devices. Outcome measures were: duration of intubation attempt, modified Cormack grades, dental trauma and difficulty of use.
In vivo both timely insertion of laryngoscope blade and introduction of the tube, no need of help or of external laryngeal displacement should be included to ascertain expertise with this new technology in patients with different grades of difficulty predicted.
Typ studie
Zápis (Očekávaný)
Kontakty a umístění
Studijní místa
-
-
-
Milan, Itálie, 20136
- Nábor
- Istituto Neurologico Besta
-
Kontakt:
- Paolo Cortellazzi, MD
- Telefonní číslo: 2420 +39022304
- E-mail: paolo.cortellazzi@istituto-besta.it
-
Dílčí vyšetřovatel:
- Alberto Sommariva, MD
-
Milano, Itálie, 20136
- Nábor
- Istituto Neurologico Besta
-
Kontakt:
- Massimo Lamperti, MD
- Telefonní číslo: 2420 +39022394
- E-mail: paolo.cortellazzi@istituto-besta.it
-
Vrchní vyšetřovatel:
- Paolo Cortellazzi, MD
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- any patient undergoing GA
Exclusion Criteria:
- patients with predicted difficult intubation undergoing awake intubation
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
patients undergoing general anesthesia
every elective patient undergoing general anesthesia for neurosurgical procedures with endotracheal intubation
|
intubation using Glidescope videolaryngoscope
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
number of attempts with Glidescope laryngoscopy necessary for beeing considered proficient
Časové okno: from induction of GA to successful intubation
|
from Glidescope blade insertion to succefull introduction of the tracheal tube and tube secured in the trachea with ETCO2 confirmation of tracheal ventilation
|
from induction of GA to successful intubation
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Features useful to define a Glidescope intubation successful
Časové okno: successfull intubation
|
the following criteria have to be satisfied: one introduction of the laryngoscope, one introduction of the tube, Cormack-leane 1, no external laryngeal displacement, time to intubation <43 seconds, no need for help of an external operator, no complications
|
successfull intubation
|
Spolupracovníci a vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Paolo Cortellazzi, MD, Fondazione I.R.C.C.S. Istituto Neurologico Carlo Besta
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Očekávaný)
Dokončení studie (Očekávaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další identifikační čísla studie
- INCCB 2012-02
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Komplikace anestezie a intubace
-
Assiut UniversityDokončeno
Klinické studie na intubation
-
Zoll Medical CorporationDokončeno