Learning and Performance of Glidescope® Videolaryngoscope Intubation
Learning and Performance of Glidescope® Videolaryngoscope Intubation in Anesthesiologists Trained in Direct Laryngoscopy: a "in Vivo" Study
Обзор исследования
Подробное описание
Glidescope® Videolaryngoscope is an angulated rigid optical device introduced in clinical practice in 2004 to facilitate endotracheal intubation.
Since its introduction potential benefits of this instrument might lie with use in patients with clinical features indicating difficult laryngoscopy or it being used as a rescue method following failed direct laryngoscopy. In a few centers was proposed and used routinely.
The performance of Glidescope® was studied in easy and difficult scenarios, in vivo and on manikins and compared with the reference standard McIntosh direct laryngoscopy. In patients with predicted or simulated difficult intubation, despite glottis visualization was improved with Glidescope®, the introduction of the tube in trachea was difficult the same as with McIntosh laryngoscopy. Training of operators before to entertain the trials varied from 20 to 50 Glidescope successful intubations. In an observational study Aziz et al. demonstrated in the two Institutions involved that the GlideScope® was used more frequently at the Institution were the failure rate was significantly lower. At this , 51 providers performed mean 21.7 GlideScope® intubations while at the other 91 providers performed 9.9 intubations.
These data highlight the important issue of how many Glidescope® intubations a provider should complete to reach a definitive clinical competence in this practice. Until now there is only one study performed on mankin comparing Glidescope® with AirTraq® and McIntosh laryngoscopes in novices . The authors concluded that despite a steep learning curve after 5 intubation difficulties in instrumentation and longer times to intubate persisted with Glidescope® in comparison with the other two devices. Outcome measures were: duration of intubation attempt, modified Cormack grades, dental trauma and difficulty of use.
In vivo both timely insertion of laryngoscope blade and introduction of the tube, no need of help or of external laryngeal displacement should be included to ascertain expertise with this new technology in patients with different grades of difficulty predicted.
Тип исследования
Регистрация (Ожидаемый)
Контакты и местонахождение
Места учебы
-
-
-
Milan, Италия, 20136
- Рекрутинг
- Istituto Neurologico Besta
-
Контакт:
- Paolo Cortellazzi, MD
- Номер телефона: 2420 +39022304
- Электронная почта: paolo.cortellazzi@istituto-besta.it
-
Младший исследователь:
- Alberto Sommariva, MD
-
Milano, Италия, 20136
- Рекрутинг
- Istituto Neurologico Besta
-
Контакт:
- Massimo Lamperti, MD
- Номер телефона: 2420 +39022394
- Электронная почта: paolo.cortellazzi@istituto-besta.it
-
Главный следователь:
- Paolo Cortellazzi, MD
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Метод выборки
Исследуемая популяция
Описание
Inclusion Criteria:
- any patient undergoing GA
Exclusion Criteria:
- patients with predicted difficult intubation undergoing awake intubation
Учебный план
Как устроено исследование?
Детали дизайна
Когорты и вмешательства
Группа / когорта |
Вмешательство/лечение |
---|---|
patients undergoing general anesthesia
every elective patient undergoing general anesthesia for neurosurgical procedures with endotracheal intubation
|
intubation using Glidescope videolaryngoscope
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
---|---|---|
number of attempts with Glidescope laryngoscopy necessary for beeing considered proficient
Временное ограничение: from induction of GA to successful intubation
|
from Glidescope blade insertion to succefull introduction of the tracheal tube and tube secured in the trachea with ETCO2 confirmation of tracheal ventilation
|
from induction of GA to successful intubation
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
---|---|---|
Features useful to define a Glidescope intubation successful
Временное ограничение: successfull intubation
|
the following criteria have to be satisfied: one introduction of the laryngoscope, one introduction of the tube, Cormack-leane 1, no external laryngeal displacement, time to intubation <43 seconds, no need for help of an external operator, no complications
|
successfull intubation
|
Соавторы и исследователи
Следователи
- Главный следователь: Paolo Cortellazzi, MD, Fondazione I.R.C.C.S. Istituto Neurologico Carlo Besta
Даты записи исследования
Изучение основных дат
Начало исследования
Первичное завершение (Ожидаемый)
Завершение исследования (Ожидаемый)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Обновления учебных записей
Последнее опубликованное обновление (Оценивать)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Другие идентификационные номера исследования
- INCCB 2012-02
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .
Клинические исследования Осложнение интубации анестезии
-
Ohio State UniversityBaxter Healthcare CorporationЗавершенныйСевофлуран | Цистоскопы | Baxter Anesthesia Торговая марка DesfluraneСоединенные Штаты