Learning and Performance of Glidescope® Videolaryngoscope Intubation
Learning and Performance of Glidescope® Videolaryngoscope Intubation in Anesthesiologists Trained in Direct Laryngoscopy: a "in Vivo" Study
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Glidescope® Videolaryngoscope is an angulated rigid optical device introduced in clinical practice in 2004 to facilitate endotracheal intubation.
Since its introduction potential benefits of this instrument might lie with use in patients with clinical features indicating difficult laryngoscopy or it being used as a rescue method following failed direct laryngoscopy. In a few centers was proposed and used routinely.
The performance of Glidescope® was studied in easy and difficult scenarios, in vivo and on manikins and compared with the reference standard McIntosh direct laryngoscopy. In patients with predicted or simulated difficult intubation, despite glottis visualization was improved with Glidescope®, the introduction of the tube in trachea was difficult the same as with McIntosh laryngoscopy. Training of operators before to entertain the trials varied from 20 to 50 Glidescope successful intubations. In an observational study Aziz et al. demonstrated in the two Institutions involved that the GlideScope® was used more frequently at the Institution were the failure rate was significantly lower. At this , 51 providers performed mean 21.7 GlideScope® intubations while at the other 91 providers performed 9.9 intubations.
These data highlight the important issue of how many Glidescope® intubations a provider should complete to reach a definitive clinical competence in this practice. Until now there is only one study performed on mankin comparing Glidescope® with AirTraq® and McIntosh laryngoscopes in novices . The authors concluded that despite a steep learning curve after 5 intubation difficulties in instrumentation and longer times to intubate persisted with Glidescope® in comparison with the other two devices. Outcome measures were: duration of intubation attempt, modified Cormack grades, dental trauma and difficulty of use.
In vivo both timely insertion of laryngoscope blade and introduction of the tube, no need of help or of external laryngeal displacement should be included to ascertain expertise with this new technology in patients with different grades of difficulty predicted.
Tipo de estudo
Inscrição (Antecipado)
Contactos e Locais
Locais de estudo
-
-
-
Milan, Itália, 20136
- Recrutamento
- Istituto Neurologico Besta
-
Contato:
- Paolo Cortellazzi, MD
- Número de telefone: 2420 +39022304
- E-mail: paolo.cortellazzi@istituto-besta.it
-
Subinvestigador:
- Alberto Sommariva, MD
-
Milano, Itália, 20136
- Recrutamento
- Istituto Neurologico Besta
-
Contato:
- Massimo Lamperti, MD
- Número de telefone: 2420 +39022394
- E-mail: paolo.cortellazzi@istituto-besta.it
-
Investigador principal:
- Paolo Cortellazzi, MD
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- any patient undergoing GA
Exclusion Criteria:
- patients with predicted difficult intubation undergoing awake intubation
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
patients undergoing general anesthesia
every elective patient undergoing general anesthesia for neurosurgical procedures with endotracheal intubation
|
intubation using Glidescope videolaryngoscope
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
number of attempts with Glidescope laryngoscopy necessary for beeing considered proficient
Prazo: from induction of GA to successful intubation
|
from Glidescope blade insertion to succefull introduction of the tracheal tube and tube secured in the trachea with ETCO2 confirmation of tracheal ventilation
|
from induction of GA to successful intubation
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Features useful to define a Glidescope intubation successful
Prazo: successfull intubation
|
the following criteria have to be satisfied: one introduction of the laryngoscope, one introduction of the tube, Cormack-leane 1, no external laryngeal displacement, time to intubation <43 seconds, no need for help of an external operator, no complications
|
successfull intubation
|
Colaboradores e Investigadores
Investigadores
- Investigador principal: Paolo Cortellazzi, MD, Fondazione I.R.C.C.S. Istituto Neurologico Carlo Besta
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Antecipado)
Conclusão do estudo (Antecipado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- INCCB 2012-02
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .