- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT01790646
Learning and Performance of Glidescope® Videolaryngoscope Intubation
Learning and Performance of Glidescope® Videolaryngoscope Intubation in Anesthesiologists Trained in Direct Laryngoscopy: a "in Vivo" Study
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Glidescope® Videolaryngoscope is an angulated rigid optical device introduced in clinical practice in 2004 to facilitate endotracheal intubation.
Since its introduction potential benefits of this instrument might lie with use in patients with clinical features indicating difficult laryngoscopy or it being used as a rescue method following failed direct laryngoscopy. In a few centers was proposed and used routinely.
The performance of Glidescope® was studied in easy and difficult scenarios, in vivo and on manikins and compared with the reference standard McIntosh direct laryngoscopy. In patients with predicted or simulated difficult intubation, despite glottis visualization was improved with Glidescope®, the introduction of the tube in trachea was difficult the same as with McIntosh laryngoscopy. Training of operators before to entertain the trials varied from 20 to 50 Glidescope successful intubations. In an observational study Aziz et al. demonstrated in the two Institutions involved that the GlideScope® was used more frequently at the Institution were the failure rate was significantly lower. At this , 51 providers performed mean 21.7 GlideScope® intubations while at the other 91 providers performed 9.9 intubations.
These data highlight the important issue of how many Glidescope® intubations a provider should complete to reach a definitive clinical competence in this practice. Until now there is only one study performed on mankin comparing Glidescope® with AirTraq® and McIntosh laryngoscopes in novices . The authors concluded that despite a steep learning curve after 5 intubation difficulties in instrumentation and longer times to intubate persisted with Glidescope® in comparison with the other two devices. Outcome measures were: duration of intubation attempt, modified Cormack grades, dental trauma and difficulty of use.
In vivo both timely insertion of laryngoscope blade and introduction of the tube, no need of help or of external laryngeal displacement should be included to ascertain expertise with this new technology in patients with different grades of difficulty predicted.
Tipo de estudio
Inscripción (Anticipado)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Milan, Italia, 20136
- Reclutamiento
- Istituto Neurologico Besta
-
Contacto:
- Paolo Cortellazzi, MD
- Número de teléfono: 2420 +39022304
- Correo electrónico: paolo.cortellazzi@istituto-besta.it
-
Sub-Investigador:
- Alberto Sommariva, MD
-
Milano, Italia, 20136
- Reclutamiento
- Istituto Neurologico Besta
-
Contacto:
- Massimo Lamperti, MD
- Número de teléfono: 2420 +39022394
- Correo electrónico: paolo.cortellazzi@istituto-besta.it
-
Investigador principal:
- Paolo Cortellazzi, MD
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- any patient undergoing GA
Exclusion Criteria:
- patients with predicted difficult intubation undergoing awake intubation
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
patients undergoing general anesthesia
every elective patient undergoing general anesthesia for neurosurgical procedures with endotracheal intubation
|
intubation using Glidescope videolaryngoscope
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
number of attempts with Glidescope laryngoscopy necessary for beeing considered proficient
Periodo de tiempo: from induction of GA to successful intubation
|
from Glidescope blade insertion to succefull introduction of the tracheal tube and tube secured in the trachea with ETCO2 confirmation of tracheal ventilation
|
from induction of GA to successful intubation
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Features useful to define a Glidescope intubation successful
Periodo de tiempo: successfull intubation
|
the following criteria have to be satisfied: one introduction of the laryngoscope, one introduction of the tube, Cormack-leane 1, no external laryngeal displacement, time to intubation <43 seconds, no need for help of an external operator, no complications
|
successfull intubation
|
Colaboradores e Investigadores
Investigadores
- Investigador principal: Paolo Cortellazzi, MD, Fondazione I.R.C.C.S. Istituto Neurologico Carlo Besta
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Anticipado)
Finalización del estudio (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Otros números de identificación del estudio
- INCCB 2012-02
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .