Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

The Accuracy of Sentinel Node Biopsy of Breast Cancer With Sonographic Abnormal Axillary Lymph Nodes

16. juni 2014 opdateret af: Tao OUYANG

Phase II Trail of Removing Sonographic Abnormal Lymph Node in Sentinel Lymph Node Biopsy of Breast Cancer Patient

  • This is a phase II, prospective, single-center, non-randomized, non-controlled study.
  • Sentinel lymph node biopsy (SNB) is a standard staging procedure in early breast cancer. The potentially increasing false negative rate of SNB was concerned if the sonographic abnormal node was not excised. The aim of this study was to evaluate the accuracy of SNB in breast cancer with sonographic abnormal axillary lymph nodes.

Studieoversigt

Status

Afsluttet

Betingelser

Undersøgelsestype

Interventionel

Tilmelding (Forventet)

200

Fase

  • Fase 2

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Beijing, Kina, 100142
        • Breast cancer, Peking University Cancer Hospital & Institute

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Barn
  • Voksen
  • Ældre voksen

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Kvinde

Beskrivelse

Inclusion Criteria:

  • histologically confirmsed primary breast cancer by core neelde biopsy or excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination before SLNB (abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm)
  • ultrasound-guided FNA cytology of these nodes were performed
  • the result of FNA cytology was negative (no tumour cell was found)
  • patient planed to perform SLNB

Exclusion Criteria:

  • pathological diagnosed ductal carcinoma in situ by excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination but FNA cytology of these nodes were not performed
  • the result of FNA cytology was positive (tumour cell was found)
  • T4d tumour
  • patient has recieved neo-adjuvant system therapy

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: negative FNA result of abnormal node
Axillary ultrasound examination was undergone for all breast cancer patients before sentinel lymph node biopsy (SLNB). If abnormal axillary lymph node was found, ultrasound-guided FNA cytology of these nodes were performed. The abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm. Patients with negative results of FNA would undergo SLNB. Technetium-99m-labeled Rituximab was used for lymphatic mapping. Before the SLNB operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.
Before the sentinel lymph node biopsy (SLNB) operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance to localize the abnormal node. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
False negative rate of sentinel node biopsy if sonographic abnormal node not be removed
Tidsramme: one week after sentinel node biopsy
one week after sentinel node biopsy

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Efterforskere

  • Ledende efterforsker: Zhaoqing Fan, M.D., Peking University Cancer Hospital & Institute

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. maj 2010

Primær færdiggørelse (Faktiske)

1. maj 2014

Studieafslutning (Faktiske)

1. juni 2014

Datoer for studieregistrering

Først indsendt

4. december 2013

Først indsendt, der opfyldte QC-kriterier

4. december 2013

Først opslået (Skøn)

9. december 2013

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

18. juni 2014

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

16. juni 2014

Sidst verificeret

1. juni 2014

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • BCP07

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Brystkræft

Abonner