Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

The Accuracy of Sentinel Node Biopsy of Breast Cancer With Sonographic Abnormal Axillary Lymph Nodes

16 de junho de 2014 atualizado por: Tao OUYANG

Phase II Trail of Removing Sonographic Abnormal Lymph Node in Sentinel Lymph Node Biopsy of Breast Cancer Patient

  • This is a phase II, prospective, single-center, non-randomized, non-controlled study.
  • Sentinel lymph node biopsy (SNB) is a standard staging procedure in early breast cancer. The potentially increasing false negative rate of SNB was concerned if the sonographic abnormal node was not excised. The aim of this study was to evaluate the accuracy of SNB in breast cancer with sonographic abnormal axillary lymph nodes.

Visão geral do estudo

Status

Concluído

Condições

Tipo de estudo

Intervencional

Inscrição (Antecipado)

200

Estágio

  • Fase 2

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Beijing, China, 100142
        • Breast cancer, Peking University Cancer Hospital & Institute

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho
  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Fêmea

Descrição

Inclusion Criteria:

  • histologically confirmsed primary breast cancer by core neelde biopsy or excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination before SLNB (abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm)
  • ultrasound-guided FNA cytology of these nodes were performed
  • the result of FNA cytology was negative (no tumour cell was found)
  • patient planed to perform SLNB

Exclusion Criteria:

  • pathological diagnosed ductal carcinoma in situ by excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination but FNA cytology of these nodes were not performed
  • the result of FNA cytology was positive (tumour cell was found)
  • T4d tumour
  • patient has recieved neo-adjuvant system therapy

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Diagnóstico
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: negative FNA result of abnormal node
Axillary ultrasound examination was undergone for all breast cancer patients before sentinel lymph node biopsy (SLNB). If abnormal axillary lymph node was found, ultrasound-guided FNA cytology of these nodes were performed. The abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm. Patients with negative results of FNA would undergo SLNB. Technetium-99m-labeled Rituximab was used for lymphatic mapping. Before the SLNB operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.
Before the sentinel lymph node biopsy (SLNB) operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance to localize the abnormal node. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
False negative rate of sentinel node biopsy if sonographic abnormal node not be removed
Prazo: one week after sentinel node biopsy
one week after sentinel node biopsy

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Zhaoqing Fan, M.D., Peking University Cancer Hospital & Institute

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de maio de 2010

Conclusão Primária (Real)

1 de maio de 2014

Conclusão do estudo (Real)

1 de junho de 2014

Datas de inscrição no estudo

Enviado pela primeira vez

4 de dezembro de 2013

Enviado pela primeira vez que atendeu aos critérios de CQ

4 de dezembro de 2013

Primeira postagem (Estimativa)

9 de dezembro de 2013

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

18 de junho de 2014

Última atualização enviada que atendeu aos critérios de controle de qualidade

16 de junho de 2014

Última verificação

1 de junho de 2014

Mais Informações

Termos relacionados a este estudo

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever