Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

The Accuracy of Sentinel Node Biopsy of Breast Cancer With Sonographic Abnormal Axillary Lymph Nodes

16 июня 2014 г. обновлено: Tao OUYANG

Phase II Trail of Removing Sonographic Abnormal Lymph Node in Sentinel Lymph Node Biopsy of Breast Cancer Patient

  • This is a phase II, prospective, single-center, non-randomized, non-controlled study.
  • Sentinel lymph node biopsy (SNB) is a standard staging procedure in early breast cancer. The potentially increasing false negative rate of SNB was concerned if the sonographic abnormal node was not excised. The aim of this study was to evaluate the accuracy of SNB in breast cancer with sonographic abnormal axillary lymph nodes.

Обзор исследования

Статус

Завершенный

Вмешательство/лечение

Тип исследования

Интервенционный

Регистрация (Ожидаемый)

200

Фаза

  • Фаза 2

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

      • Beijing, Китай, 100142
        • Breast cancer, Peking University Cancer Hospital & Institute

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Ребенок
  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Женский

Описание

Inclusion Criteria:

  • histologically confirmsed primary breast cancer by core neelde biopsy or excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination before SLNB (abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm)
  • ultrasound-guided FNA cytology of these nodes were performed
  • the result of FNA cytology was negative (no tumour cell was found)
  • patient planed to perform SLNB

Exclusion Criteria:

  • pathological diagnosed ductal carcinoma in situ by excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination but FNA cytology of these nodes were not performed
  • the result of FNA cytology was positive (tumour cell was found)
  • T4d tumour
  • patient has recieved neo-adjuvant system therapy

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Диагностика
  • Распределение: Н/Д
  • Интервенционная модель: Одногрупповое задание
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: negative FNA result of abnormal node
Axillary ultrasound examination was undergone for all breast cancer patients before sentinel lymph node biopsy (SLNB). If abnormal axillary lymph node was found, ultrasound-guided FNA cytology of these nodes were performed. The abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm. Patients with negative results of FNA would undergo SLNB. Technetium-99m-labeled Rituximab was used for lymphatic mapping. Before the SLNB operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.
Before the sentinel lymph node biopsy (SLNB) operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance to localize the abnormal node. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Временное ограничение
False negative rate of sentinel node biopsy if sonographic abnormal node not be removed
Временное ограничение: one week after sentinel node biopsy
one week after sentinel node biopsy

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Следователи

  • Главный следователь: Zhaoqing Fan, M.D., Peking University Cancer Hospital & Institute

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования

1 мая 2010 г.

Первичное завершение (Действительный)

1 мая 2014 г.

Завершение исследования (Действительный)

1 июня 2014 г.

Даты регистрации исследования

Первый отправленный

4 декабря 2013 г.

Впервые представлено, что соответствует критериям контроля качества

4 декабря 2013 г.

Первый опубликованный (Оценивать)

9 декабря 2013 г.

Обновления учебных записей

Последнее опубликованное обновление (Оценивать)

18 июня 2014 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

16 июня 2014 г.

Последняя проверка

1 июня 2014 г.

Дополнительная информация

Термины, связанные с этим исследованием

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться