The Accuracy of Sentinel Node Biopsy of Breast Cancer With Sonographic Abnormal Axillary Lymph Nodes

2014. június 16. frissítette: Tao OUYANG

Phase II Trail of Removing Sonographic Abnormal Lymph Node in Sentinel Lymph Node Biopsy of Breast Cancer Patient

  • This is a phase II, prospective, single-center, non-randomized, non-controlled study.
  • Sentinel lymph node biopsy (SNB) is a standard staging procedure in early breast cancer. The potentially increasing false negative rate of SNB was concerned if the sonographic abnormal node was not excised. The aim of this study was to evaluate the accuracy of SNB in breast cancer with sonographic abnormal axillary lymph nodes.

A tanulmány áttekintése

Állapot

Befejezve

Körülmények

Tanulmány típusa

Beavatkozó

Beiratkozás (Várható)

200

Fázis

  • 2. fázis

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi helyek

      • Beijing, Kína, 100142
        • Breast cancer, Peking University Cancer Hospital & Institute

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

  • Gyermek
  • Felnőtt
  • Idősebb felnőtt

Egészséges önkénteseket fogad

Nem

Tanulmányozható nemek

Női

Leírás

Inclusion Criteria:

  • histologically confirmsed primary breast cancer by core neelde biopsy or excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination before SLNB (abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm)
  • ultrasound-guided FNA cytology of these nodes were performed
  • the result of FNA cytology was negative (no tumour cell was found)
  • patient planed to perform SLNB

Exclusion Criteria:

  • pathological diagnosed ductal carcinoma in situ by excisional biospy
  • abnormal axillary lymph node was found by ultrasound examination but FNA cytology of these nodes were not performed
  • the result of FNA cytology was positive (tumour cell was found)
  • T4d tumour
  • patient has recieved neo-adjuvant system therapy

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

  • Elsődleges cél: Diagnosztikai
  • Kiosztás: N/A
  • Beavatkozó modell: Egyetlen csoportos hozzárendelés
  • Maszkolás: Nincs (Open Label)

Fegyverek és beavatkozások

Résztvevő csoport / kar
Beavatkozás / kezelés
Kísérleti: negative FNA result of abnormal node
Axillary ultrasound examination was undergone for all breast cancer patients before sentinel lymph node biopsy (SLNB). If abnormal axillary lymph node was found, ultrasound-guided FNA cytology of these nodes were performed. The abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm. Patients with negative results of FNA would undergo SLNB. Technetium-99m-labeled Rituximab was used for lymphatic mapping. Before the SLNB operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.
Before the sentinel lymph node biopsy (SLNB) operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance to localize the abnormal node. In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Időkeret
False negative rate of sentinel node biopsy if sonographic abnormal node not be removed
Időkeret: one week after sentinel node biopsy
one week after sentinel node biopsy

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Szponzor

Nyomozók

  • Kutatásvezető: Zhaoqing Fan, M.D., Peking University Cancer Hospital & Institute

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete

2010. május 1.

Elsődleges befejezés (Tényleges)

2014. május 1.

A tanulmány befejezése (Tényleges)

2014. június 1.

Tanulmányi regisztráció dátumai

Először benyújtva

2013. december 4.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2013. december 4.

Első közzététel (Becslés)

2013. december 9.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Becslés)

2014. június 18.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2014. június 16.

Utolsó ellenőrzés

2014. június 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .