- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT02005926
The Accuracy of Sentinel Node Biopsy of Breast Cancer With Sonographic Abnormal Axillary Lymph Nodes
16 de junio de 2014 actualizado por: Tao OUYANG
Phase II Trail of Removing Sonographic Abnormal Lymph Node in Sentinel Lymph Node Biopsy of Breast Cancer Patient
- This is a phase II, prospective, single-center, non-randomized, non-controlled study.
- Sentinel lymph node biopsy (SNB) is a standard staging procedure in early breast cancer. The potentially increasing false negative rate of SNB was concerned if the sonographic abnormal node was not excised. The aim of this study was to evaluate the accuracy of SNB in breast cancer with sonographic abnormal axillary lymph nodes.
Descripción general del estudio
Estado
Terminado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Intervencionista
Inscripción (Anticipado)
200
Fase
- Fase 2
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
-
Beijing, Porcelana, 100142
- Breast cancer, Peking University Cancer Hospital & Institute
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
- Niño
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Femenino
Descripción
Inclusion Criteria:
- histologically confirmsed primary breast cancer by core neelde biopsy or excisional biospy
- abnormal axillary lymph node was found by ultrasound examination before SLNB (abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm)
- ultrasound-guided FNA cytology of these nodes were performed
- the result of FNA cytology was negative (no tumour cell was found)
- patient planed to perform SLNB
Exclusion Criteria:
- pathological diagnosed ductal carcinoma in situ by excisional biospy
- abnormal axillary lymph node was found by ultrasound examination but FNA cytology of these nodes were not performed
- the result of FNA cytology was positive (tumour cell was found)
- T4d tumour
- patient has recieved neo-adjuvant system therapy
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: negative FNA result of abnormal node
Axillary ultrasound examination was undergone for all breast cancer patients before sentinel lymph node biopsy (SLNB).
If abnormal axillary lymph node was found, ultrasound-guided FNA cytology of these nodes were performed.
The abnormal nodes were defined as completely hypoechoic node, asymmetric focal hypoechoic node, cortical lobulation and cortical thickness >3mm.
Patients with negative results of FNA would undergo SLNB.
Technetium-99m-labeled Rituximab was used for lymphatic mapping.
Before the SLNB operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance.
In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.
|
Before the sentinel lymph node biopsy (SLNB) operation, a hookwire was placed at the suspicious axillary lymph node by ultrasound guidance to localize the abnormal node.
In the SLNB operation, radioactive nodes and wire-localized nodes were removed and labeled separately for pathological examination.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
False negative rate of sentinel node biopsy if sonographic abnormal node not be removed
Periodo de tiempo: one week after sentinel node biopsy
|
one week after sentinel node biopsy
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Investigadores
- Investigador principal: Zhaoqing Fan, M.D., Peking University Cancer Hospital & Institute
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio
1 de mayo de 2010
Finalización primaria (Actual)
1 de mayo de 2014
Finalización del estudio (Actual)
1 de junio de 2014
Fechas de registro del estudio
Enviado por primera vez
4 de diciembre de 2013
Primero enviado que cumplió con los criterios de control de calidad
4 de diciembre de 2013
Publicado por primera vez (Estimar)
9 de diciembre de 2013
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
18 de junio de 2014
Última actualización enviada que cumplió con los criterios de control de calidad
16 de junio de 2014
Última verificación
1 de junio de 2014
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- BCP07
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .