- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT07606690
The Geniohyoid Muscle in Critical Illness
Assessing the Feasibility and Reliability of an Ultrasound-based Method of Measuring the Geniohyoid Muscle in Mechanically Ventilated Patients - an Observational Study
Many patients lose muscle due to being unwell in an intensive care unit. This muscle loss can lead to weakness of the arms and legs when they leave the unit, and when they go home. For many years investigators have measured the size of these arm and leg muscles using an ultrasound machine, to take a picture of the muscles.
It is also known that patients who are on a ventilator (or "breathing machine") often have problems swallowing when the breathing tube is removed from their mouth. This may be because the muscles of swallowing may also shrink. One of these muscles sits under the jaw and can be measured with ultrasound - the method has been shown to be accurate and reliable in awake volunteers, but these volunteers are usually sat upright in a chair with their mouth closed.
Before it can be assed whether these muscles get smaller, it is needed to assess whether the chosen method is suitable in patients on a ventilator; these patients are lying in bed, and their mouths are open slightly due to the breathing tube.
Proposed Method
This investigation will measure the size of a muscle under the jaw (called the geniohyoid muscle) in patients who are sedated and have a breathing tube in their mouth connected to a ventilator.
Using a normal hospital ultrasound machine, one researcher will place the ultrasound probe under the patient's jaw. When the researcher is happy the probe is in the right place, they will take a picture of the muscle and measure its size and thickness. After a short break, the researcher will repeat this process. After a second short break, another researcher who did not watch the first researcher will also place the probe under the jaw and take a picture of the muscle.
These measurements can be used to to answer the following questions:
- How many patients scanned produced images that could be measured?
- How consistent are the measurements if one person measures the same muscle twice?
- If two people measure the same muscle, do their measurements agree with each other?
The patients will be under sedation when they take part in the study. Because of this, they cannot consent to take part in the study. The patient's next of kin or carer would advise on whether the patient would want to take part. When the patient is awake and has the breathing tube removed, the research team would ask them to sign a consent form to use their data.
Studieoversigt
Status
Betingelser
Detaljeret beskrivelse
Introduction
Many patients who are mechanically ventilated due to critical illness have difficulty in swallowing after the endotracheal tube is removed, a phenomenon known as Post Extubation Dsyphagia (PED). Although multifactorial, atrophy of the swallowing muscles is a potential cause.
Ultrasound is a commonly used investigative modality for the measurement of muscles in critically unwell patients. Measurements can be performed repeatedly over time to track changes in muscle size during the course of a patient's admission. In critically unwell patients, much of the research is focussed on muscles of the limbs and trunk. The muscles of swallowing have been measured using ultrasound, but in awake patients adopting an optimal seated position. Critically unwell patients are bedbound, and the endotracheal tube leaves their mouth in an open position. Before embarking on a study using ultrasound to attempt to track changes in muscle size in the muscles of swallowing, the investigators first wish to assess if such a method is both feasible and reliable.
Methods
Critically unwell patients who are sedated and mechanically ventilated will be recruited into the study after discussion with a patient's personal consultee. The geniohyoid (GH) muscle will be scanned in both the coronal and sagittal planes. The patient will be scanned three times. Twice by one assessor, and once by a second assessor. Cross sectional areas (CSA) of GH will be measured at a later time using image processing software (ImageJ, NIH, USA). Echogenicity, a measurement of the brightness of muscle on ultrasound, will also be assessed.
Results
The primary outcome is to obtain the proportion of patients whose images from ultrasound can provide satisfactory measurement data, in each plane. Furthermore, we will assess the repeatability of each measurement by calculating the intra-rater agreement, and the inter-rater agreement to assess agreement between assessors. An estimate of the mean CSA in each plane will be calculated.
Conclusions
This preliminary data will give us an estimate of the proportion of patients who can provide satisfactory images of GH, in preparation for a larger study assessing longitudinal changes in CSA. Further, the study will give data on both the inter- and intra-rather agreement of the method.
Undersøgelsestype
Tilmelding (Anslået)
Kontakter og lokationer
Studiesteder
-
-
-
Warrington, Det Forenede Kongerige, WA5 1QG
- Intensive Care Unit
-
Kontakt:
- Peter Turton, MBChB (Hons) MPhil FRCA FFICM
- Telefonnummer: 5594 01925 635911
- E-mail: peter.turton1@nhs.net
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
Inclusion Criteria:
· Mechanically ventilated patient on the intensive care unit
- Endotracheal tube via the mouth in-situ (size 7.0 and above)
- Can be recruited at any time during their admission
Exclusion Criteria:
· Ventilated via a nasal endotracheal tube
- Ventilated via a tracheostomy
- Ventilated via a micro-endotracheal tube
- Any previous or active history of head and neck cancer
- Any previous head and neck surgery (excluding tonsillectomy and adenoidectomy)
- Any cranio-facial deformity that would render access to the jaw difficult, including but not limited to short thymo-mental distance
- Any neuromuscular disorder, including previous stroke
- Any previous history of dysphagia or swallowing disorder
- Pregnant patients
- Patients under 18 years of age
- Agitation or movement that would make measurement difficult or inaccurate
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Kohorter og interventioner
Gruppe / kohorte |
|---|
|
Mechanically ventilated patient group
Any eligible patient who is being mechanically ventilated in the site's intensive care unit, via an endotracheal tube.
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Satisfactory image acquisition of the geniohyoid muscle in the coronal plane (n, proportion)
Tidsramme: Day 1 (patients are only on the day of the ultrasound)
|
To obtain an estimate for the proportion of patients in which satisfactory images can be measured, in both measured planes (coronal and sagittal views).
An "unsatisfactory" image is due to either the investigator being unable to adequately visualise the GH muscle with the probe (e.g.
due to subcutaneous fat, difficult patient positioning, or when an image has been obtained, the offline CSA measurement cannot be performed due to inadequate visualisation of the muscle's fascial border.
In addition, the co-efficient of variance of the three images taken must be less than 5%.
|
Day 1 (patients are only on the day of the ultrasound)
|
|
Satisfactory image acquisition of the geniohyoid muscle, sagittal plane (n, proportion)
Tidsramme: Day 1 - patients are only in the study on the day of the ultrasound scan
|
To obtain an estimate for the proportion of patients in which satisfactory images can be measured, in the sagittal plane.
An "unsatisfactory" image is due to either the investigator being unable to adequately visualise the GH muscle with the probe (e.g.
due to subcutaneous fat, difficult patient positioning, or when an image has been obtained, the offline CSA measurement cannot be performed due to inadequate visualisation of the muscle's fascial border.
In addition, the co-efficient of variance of the three images taken must be less than 5%.
|
Day 1 - patients are only in the study on the day of the ultrasound scan
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Intra-rater agreement, cross sectional area of geniohyoid muscle, coronal plane
Tidsramme: Day 1
|
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the coronal plane.
After a short break, a second set of 3 images (set B) will be taken.
Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and B, and calculating the intra-class correlation co-efficient for consistency.
|
Day 1
|
|
Intra-rater agreement, cross sectional area of geniohyoid muscle, sagittal plane
Tidsramme: Day 1
|
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the sagittal plane.
After a short break, a second set of 3 images (set B) will be taken.
Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and B, and calculating the intra-class correlation co-efficient for consistency.
|
Day 1
|
|
Inter-rater agreement, cross sectional area of geniohyoid muscle, coronal plane
Tidsramme: Day 1
|
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the coronal plane.
After a short break, investigator B will take a second set of 3 images (set C) Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and C, and calculating the intra-class correlation co-efficient for agreement.
|
Day 1
|
|
Inter-rater agreement, cross sectional area of geniohyoid muscle, sagittal plane
Tidsramme: Day 1
|
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the coronal plane.
After a short break, investigator B will take a second set of 3 images (set C) Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and C, and calculating the intra-class correlation co-efficient for agreement.
|
Day 1
|
|
Intra-rater agreement, echogenicity of the geniohyoid muscle, sagittal plane
Tidsramme: Day 1
|
Investigator A will have taken 2 sets of 3 images (sets A and B) of the geniohyoid muscle in the sagittal plane.
Echogenicity will be measured offline using appropriate imaging software (Image J, NIH) and compared by mean and standard deviation, and by intra-class correlation coefficient for consistency.
|
Day 1
|
|
Inter-rater agreement, echogenicity of the geniohyoid muscle, sagittal plane
Tidsramme: Day 1
|
Investigator A will have taken 2 sets of 3 images (sets A and B) of the geniohyoid muscle in the sagittal plane, and investigator B will take set of 3 images (set C).
Echogenicity will be measured offline using appropriate imaging software (Image J, NIH) and compared by mean and standard deviation, and by intra-class correlation coefficient for absolute agreement.
|
Day 1
|
Samarbejdspartnere og efterforskere
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Anslået)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Andre undersøgelses-id-numre
- W0001
- 26/NW/0011 (Anden identifikator: REC - North West Greater Manchester South)
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
IPD-planbeskrivelse
IPD-delingstidsramme
IPD-delingsadgangskriterier
IPD-deling Understøttende informationstype
- STUDY_PROTOCOL
- ICF
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Mekanisk ventilation
-
Rawalpindi Medical CollegeRekrutteringMekanisk ventilation | Køretryk | Lungebeskyttende ventilationPakistan
-
Rabin Medical CenterUkendtMekanisk ventilation | Fravænning | Langvarig ventilation
-
Drägerwerk AG & Co. KGaAUniversity of Göttingen; Prof. Dr. med. ImhoffSuspenderetMekanisk ventilation | Ventilation Perfusion MismatchTyskland
-
Thammasat UniversityAfsluttetLangvarig mekanisk ventilation | Mekanisk ventilation i hjemmetThailand
-
Universitätsklinikum Hamburg-EppendorfAktiv, ikke rekrutterendeLuftvejsstyring | Non-invasiv ventilation | Maske ventilationTyskland
-
Cairo UniversityAfsluttetFravænningsfejl | Fravænning fra mekanisk ventilation | Mekanisk ventilationEgypten
-
Capital Medical UniversityUkendtMekanisk ventilation | Neurokirurgi | Elektrisk impedanstomografi | Inhomogen ventilationKina
-
Ligue Pulmonaire GenevoiseAfsluttet
-
Thomas Jefferson UniversityAfsluttetMekanisk ventilation | Point of Care Ultralyd | Iltning | Manuel ventilation | Hjertefunktionsforstyrrelse PostoperativForenede Stater
-
Hospital do CoracaoIkke rekrutterer endnuFravænningsfejl | Fravænning fra mekanisk ventilation | Fravænning fra mekanisk ventilation, ekstubation