Corneal Power, Astigmatism, and Aberration Changes After LASIK
4. April 2018 aktualisiert von: David Huang, Oregon Health and Science University
Observational Study of Corneal Power, Astigmatism, and Aberration Changes After LASIK
The primary goal of the study is to determine if Optical Coherence Tomography (OCT) measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography.
A second goal is to evaluate OCT-based epithelial thickness mapping.
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
A third goal is to assess the repeatability of OCT measurements.
A fourth goal is to develop a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
Studienübersicht
Status
Abgeschlossen
Detaillierte Beschreibung
A prospective observational study on refraction and HOA changes after LASIK will be conducted at OHSU and Baylor.
We will enroll 50 subjects undergoing routine LASIK for the correction of myopia or hyperopia.
The Optovue anterior segment OCT prototype will be used to measure corneal power, astigmatism, HOA, and epithelial thickness map.
The ultrahigh-speed MIT OCT prototypes will also be used when they become available.
A comprehensive eye examination will be performed preoperatively.
OCT scan, manifest refraction, visual acuity, Placido-ring corneal topography, slit scanning/Scheimpflug camera, and wavefront measurements will be acquired preoperatively and 3-6 months after the surgery.
The LASIK-induced refraction and wavefront HOA changes will be used as the reference standard to evaluate the accuracy of OCT-measured corneal power, astigmatism, and HOA changes.
The primary goal of the study is to determine if OCT measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography.
A second goal is to evaluate OCT-based epithelial thickness mapping.
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
A third goal is to assess the repeatability of OCT measurements.
A fourth goal is to develop a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
The reference standard for lens focusing power and astigmatism will be based on a Gaussian optics model that takes as inputs manifest refraction, crystalline lens position, axial eye length, and OCT corneal power and astigmatism measurements.
The reference standard for lens HOA will be the difference between wavefront HOA and corneal HOA.
For each eye, the best-fit effective index of the lens will be found so that OCT measurements will match the reference data.
Although the lens index is likely to be higher centrally than peripherally, this secondary perturbation will be accounted for by a posterior shift of the posterior lens capsule in OCT images, due to the fact that apparent distances in OCT images is a product of physical distance and optical group index.
Thus HOA due to index variation in the lens would translate to unevenness in the posterior capsule surface that could be measured with OCT.
Studientyp
Beobachtungs
Einschreibung (Tatsächlich)
22
Kontakte und Standorte
Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.
Studienorte
-
-
Oregon
-
Portland, Oregon, Vereinigte Staaten, 97239
- Oregon Health & Science University
-
-
Teilnahmekriterien
Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.
Zulassungskriterien
Studienberechtigtes Alter
18 Jahre und älter (Erwachsene, Älterer Erwachsener)
Akzeptiert gesunde Freiwillige
Nein
Studienberechtigte Geschlechter
Alle
Probenahmeverfahren
Nicht-Wahrscheinlichkeitsprobe
Studienpopulation
Subjects undergoing routine LASIK for the correction of myopia or hyperopia with or without astigmatism
Beschreibung
Inclusion Criteria:
1. Patients who qualify for primary LASIK for either myopia or hyperopia, with or without astigmatism.
Exclusion Criteria:
- Inability to give informed consent.
- Inability to maintain stable fixation for OCT imaging.
- Inability to commit to required visits to complete the study.
- Eyes with concurrent cataract, retinal diseases, glaucoma, or other eye conditions that may limit the visual outcome after surgery
Studienplan
Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.
Wie ist die Studie aufgebaut?
Designdetails
- Beobachtungsmodelle: Nur Fall
- Zeitperspektiven: Interessent
Kohorten und Interventionen
Gruppe / Kohorte |
|---|
|
LASIK
Subjects undergoing routine LASIK for the correction of myopia or hyperopia.
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
OCT measurement of corneal power and astigmatism vs Placido-ring
Zeitfenster: 5 year
|
primary goal of the study is to determine if OCT measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography
|
5 year
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
An evaluation of OCT-based epithelial thickness mapping
Zeitfenster: 5 year
|
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
|
5 year
|
|
OCT measurements repeatability
Zeitfenster: 5 year
|
An assessment of the repeatability of OCT measurements
|
5 year
|
|
The Development of a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens
Zeitfenster: 5 year
|
The Development of a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
|
5 year
|
Mitarbeiter und Ermittler
Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.
Mitarbeiter
Ermittler
- Hauptermittler: David Huang, MD, PhD, Oregon Health & Science Universtiy
Studienaufzeichnungsdaten
Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.
Haupttermine studieren
Studienbeginn
1. Januar 2011
Primärer Abschluss (Tatsächlich)
31. August 2017
Studienabschluss (Tatsächlich)
31. August 2017
Studienanmeldedaten
Zuerst eingereicht
2. Juli 2013
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
2. Juli 2013
Zuerst gepostet (Schätzen)
9. Juli 2013
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
5. April 2018
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
4. April 2018
Zuletzt verifiziert
1. April 2018
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- OHSU IRB#6612
- R01EY018184 (US NIH Stipendium/Vertrag)
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Nein
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Nein
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Nein
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .