Corneal Power, Astigmatism, and Aberration Changes After LASIK
4 de abril de 2018 atualizado por: David Huang, Oregon Health and Science University
Observational Study of Corneal Power, Astigmatism, and Aberration Changes After LASIK
The primary goal of the study is to determine if Optical Coherence Tomography (OCT) measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography.
A second goal is to evaluate OCT-based epithelial thickness mapping.
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
A third goal is to assess the repeatability of OCT measurements.
A fourth goal is to develop a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
Visão geral do estudo
Status
Concluído
Descrição detalhada
A prospective observational study on refraction and HOA changes after LASIK will be conducted at OHSU and Baylor.
We will enroll 50 subjects undergoing routine LASIK for the correction of myopia or hyperopia.
The Optovue anterior segment OCT prototype will be used to measure corneal power, astigmatism, HOA, and epithelial thickness map.
The ultrahigh-speed MIT OCT prototypes will also be used when they become available.
A comprehensive eye examination will be performed preoperatively.
OCT scan, manifest refraction, visual acuity, Placido-ring corneal topography, slit scanning/Scheimpflug camera, and wavefront measurements will be acquired preoperatively and 3-6 months after the surgery.
The LASIK-induced refraction and wavefront HOA changes will be used as the reference standard to evaluate the accuracy of OCT-measured corneal power, astigmatism, and HOA changes.
The primary goal of the study is to determine if OCT measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography.
A second goal is to evaluate OCT-based epithelial thickness mapping.
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
A third goal is to assess the repeatability of OCT measurements.
A fourth goal is to develop a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
The reference standard for lens focusing power and astigmatism will be based on a Gaussian optics model that takes as inputs manifest refraction, crystalline lens position, axial eye length, and OCT corneal power and astigmatism measurements.
The reference standard for lens HOA will be the difference between wavefront HOA and corneal HOA.
For each eye, the best-fit effective index of the lens will be found so that OCT measurements will match the reference data.
Although the lens index is likely to be higher centrally than peripherally, this secondary perturbation will be accounted for by a posterior shift of the posterior lens capsule in OCT images, due to the fact that apparent distances in OCT images is a product of physical distance and optical group index.
Thus HOA due to index variation in the lens would translate to unevenness in the posterior capsule surface that could be measured with OCT.
Tipo de estudo
Observacional
Inscrição (Real)
22
Contactos e Locais
Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.
Locais de estudo
-
-
Oregon
-
Portland, Oregon, Estados Unidos, 97239
- Oregon Health & Science University
-
-
Critérios de participação
Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.
Critérios de elegibilidade
Idades elegíveis para estudo
18 anos e mais velhos (Adulto, Adulto mais velho)
Aceita Voluntários Saudáveis
Não
Gêneros Elegíveis para o Estudo
Tudo
Método de amostragem
Amostra Não Probabilística
População do estudo
Subjects undergoing routine LASIK for the correction of myopia or hyperopia with or without astigmatism
Descrição
Inclusion Criteria:
1. Patients who qualify for primary LASIK for either myopia or hyperopia, with or without astigmatism.
Exclusion Criteria:
- Inability to give informed consent.
- Inability to maintain stable fixation for OCT imaging.
- Inability to commit to required visits to complete the study.
- Eyes with concurrent cataract, retinal diseases, glaucoma, or other eye conditions that may limit the visual outcome after surgery
Plano de estudo
Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: Caso-somente
- Perspectivas de Tempo: Prospectivo
Coortes e Intervenções
Grupo / Coorte |
|---|
|
LASIK
Subjects undergoing routine LASIK for the correction of myopia or hyperopia.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
OCT measurement of corneal power and astigmatism vs Placido-ring
Prazo: 5 year
|
primary goal of the study is to determine if OCT measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography
|
5 year
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
An evaluation of OCT-based epithelial thickness mapping
Prazo: 5 year
|
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
|
5 year
|
|
OCT measurements repeatability
Prazo: 5 year
|
An assessment of the repeatability of OCT measurements
|
5 year
|
|
The Development of a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens
Prazo: 5 year
|
The Development of a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
|
5 year
|
Colaboradores e Investigadores
É aqui que você encontrará pessoas e organizações envolvidas com este estudo.
Patrocinador
Colaboradores
Investigadores
- Investigador principal: David Huang, MD, PhD, Oregon Health & Science Universtiy
Datas de registro do estudo
Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.
Datas Principais do Estudo
Início do estudo
1 de janeiro de 2011
Conclusão Primária (Real)
31 de agosto de 2017
Conclusão do estudo (Real)
31 de agosto de 2017
Datas de inscrição no estudo
Enviado pela primeira vez
2 de julho de 2013
Enviado pela primeira vez que atendeu aos critérios de CQ
2 de julho de 2013
Primeira postagem (Estimativa)
9 de julho de 2013
Atualizações de registro de estudo
Última Atualização Postada (Real)
5 de abril de 2018
Última atualização enviada que atendeu aos critérios de controle de qualidade
4 de abril de 2018
Última verificação
1 de abril de 2018
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- OHSU IRB#6612
- R01EY018184 (Concessão/Contrato do NIH dos EUA)
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Não
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Não
produto fabricado e exportado dos EUA
Não
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .