- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT01893671
Corneal Power, Astigmatism, and Aberration Changes After LASIK
4 апреля 2018 г. обновлено: David Huang, Oregon Health and Science University
Observational Study of Corneal Power, Astigmatism, and Aberration Changes After LASIK
The primary goal of the study is to determine if Optical Coherence Tomography (OCT) measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography.
A second goal is to evaluate OCT-based epithelial thickness mapping.
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
A third goal is to assess the repeatability of OCT measurements.
A fourth goal is to develop a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
Обзор исследования
Статус
Завершенный
Подробное описание
A prospective observational study on refraction and HOA changes after LASIK will be conducted at OHSU and Baylor.
We will enroll 50 subjects undergoing routine LASIK for the correction of myopia or hyperopia.
The Optovue anterior segment OCT prototype will be used to measure corneal power, astigmatism, HOA, and epithelial thickness map.
The ultrahigh-speed MIT OCT prototypes will also be used when they become available.
A comprehensive eye examination will be performed preoperatively.
OCT scan, manifest refraction, visual acuity, Placido-ring corneal topography, slit scanning/Scheimpflug camera, and wavefront measurements will be acquired preoperatively and 3-6 months after the surgery.
The LASIK-induced refraction and wavefront HOA changes will be used as the reference standard to evaluate the accuracy of OCT-measured corneal power, astigmatism, and HOA changes.
The primary goal of the study is to determine if OCT measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography.
A second goal is to evaluate OCT-based epithelial thickness mapping.
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
A third goal is to assess the repeatability of OCT measurements.
A fourth goal is to develop a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
The reference standard for lens focusing power and astigmatism will be based on a Gaussian optics model that takes as inputs manifest refraction, crystalline lens position, axial eye length, and OCT corneal power and astigmatism measurements.
The reference standard for lens HOA will be the difference between wavefront HOA and corneal HOA.
For each eye, the best-fit effective index of the lens will be found so that OCT measurements will match the reference data.
Although the lens index is likely to be higher centrally than peripherally, this secondary perturbation will be accounted for by a posterior shift of the posterior lens capsule in OCT images, due to the fact that apparent distances in OCT images is a product of physical distance and optical group index.
Thus HOA due to index variation in the lens would translate to unevenness in the posterior capsule surface that could be measured with OCT.
Тип исследования
Наблюдательный
Регистрация (Действительный)
22
Контакты и местонахождение
В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.
Места учебы
-
-
Oregon
-
Portland, Oregon, Соединенные Штаты, 97239
- Oregon Health & Science University
-
-
Критерии участия
Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.
Критерии приемлемости
Возраст, подходящий для обучения
18 лет и старше (Взрослый, Пожилой взрослый)
Принимает здоровых добровольцев
Нет
Полы, имеющие право на обучение
Все
Метод выборки
Невероятностная выборка
Исследуемая популяция
Subjects undergoing routine LASIK for the correction of myopia or hyperopia with or without astigmatism
Описание
Inclusion Criteria:
1. Patients who qualify for primary LASIK for either myopia or hyperopia, with or without astigmatism.
Exclusion Criteria:
- Inability to give informed consent.
- Inability to maintain stable fixation for OCT imaging.
- Inability to commit to required visits to complete the study.
- Eyes with concurrent cataract, retinal diseases, glaucoma, or other eye conditions that may limit the visual outcome after surgery
Учебный план
В этом разделе представлена подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.
Как устроено исследование?
Детали дизайна
- Наблюдательные модели: Только для случая
- Временные перспективы: Перспективный
Когорты и вмешательства
Группа / когорта |
|---|
|
LASIK
Subjects undergoing routine LASIK for the correction of myopia or hyperopia.
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
OCT measurement of corneal power and astigmatism vs Placido-ring
Временное ограничение: 5 year
|
primary goal of the study is to determine if OCT measurement of corneal power and astigmatism is more accurate than conventional Placido-ring corneal topography
|
5 year
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
An evaluation of OCT-based epithelial thickness mapping
Временное ограничение: 5 year
|
The postoperative epithelial thickness variation will be used to calculate refractive effects and calibrate the smoothing parameter in the mathematical model relating corneal mean curvature and epithelial thickness.
|
5 year
|
|
OCT measurements repeatability
Временное ограничение: 5 year
|
An assessment of the repeatability of OCT measurements
|
5 year
|
|
The Development of a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens
Временное ограничение: 5 year
|
The Development of a method of estimating the focusing power, astigmatism, and HOA of the crystalline lens based on measurements of the lens' anterior and posterior capsular topographies and positions with the ultrahigh-speed MIT OCT prototype.
|
5 year
|
Соавторы и исследователи
Здесь вы найдете людей и организации, участвующие в этом исследовании.
Соавторы
Следователи
- Главный следователь: David Huang, MD, PhD, Oregon Health & Science Universtiy
Даты записи исследования
Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.
Изучение основных дат
Начало исследования
1 января 2011 г.
Первичное завершение (Действительный)
31 августа 2017 г.
Завершение исследования (Действительный)
31 августа 2017 г.
Даты регистрации исследования
Первый отправленный
2 июля 2013 г.
Впервые представлено, что соответствует критериям контроля качества
2 июля 2013 г.
Первый опубликованный (Оценивать)
9 июля 2013 г.
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
5 апреля 2018 г.
Последнее отправленное обновление, отвечающее критериям контроля качества
4 апреля 2018 г.
Последняя проверка
1 апреля 2018 г.
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- OHSU IRB#6612
- R01EY018184 (Грант/контракт NIH США)
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Нет
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Нет
продукт, произведенный в США и экспортированный из США.
Нет
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .