Effect of Laryngeal Mask Cuff Pressure in Geriatric Patients

5. August 2015 aktualisiert von: Sule Ozbilgin, Dokuz Eylul University

Effect of Laryngeal Mask Cuff Pressure on Postoperative Pharyngolaryngeal Complications in Geriatric Patients

Laryngeal Mask is widely used for air-way management during anaesthesia. Pharyngolaryngeal morbidity linked to laryngeal mask use is related to correct choice of mask size, placement technique, placement of the laryngeal mask in the correct position on the larynx, cuff volume and cuff pressure. It has been stated that keeping laryngeal mask cuff pressure below 45 mmHg (60 centimeter of water(cmH2O) ) can prevent pharyngolaryngeal morbidity related to laryngeal mask (throat pain, dysphonia, dysphagia) and shown that using a manometer after Laryngeal Mask Unique placement to limit pressure within the cuff can reduce this morbidity by nearly 70%. Studies commenting on pharyngolaryngeal morbidity generally do not choose a certain age group and cover stages including very young and middle-aged groups. In the literature only one similar study on the geriatric age group was found.

The aim of this study is to compare the postoperative pharyngolaryngeal morbidity in a group with cuff pressure held to 44 mmHg (60 cmH2O with a manometer and a group with Laryngeal Mask cuff inflated without reference to pressure in the geriatric age group with indications for Laryngeal Mask Unique placement.

Studienübersicht

Detaillierte Beschreibung

This study received permission from Dokuz Eylül University Medical Faculty Non-Interventional Ethics Committee and informed consent was obtained from the patients. Ninety patients above the age of 65 with American Society of Anesthesiologists (ASA) physiological classification group I-III, undergoing elective surgery and with indications for laryngeal mask placement participated in this prospective, randomized and double blind study.

Patients taken to the operating room were given standard monitoring (ECG, pulse oxymetry, non-invasive blood pressure) and BIS monitoring [BIS-Vista ™ (Aspect Medical Systems, USA)] before anesthesia induction.

After patients were preoxygenated with 6 L/min oxygen through a face mask for 3 minutes anesthesia induction was provided by 0.02 mg/kg midazolam, 1-2 µg/kg fentanyl and 1-2 mg/kg propofol. During respiration Airway was not used, unless there was ventilation difficulty with the face mask. Before insertion the laryngeal mask used in daily routine (Laryngeal Mask Unique® (LMU)) was lubricated with a water-based gel and the cuff was completely deflated. After induction when bispectral index (BIS) values were between 40 and 60 and sufficient chin relaxation was obtained for patients weighing less than 50 kg no. 3 LMU, for those between 50-90 kg no. 4 and for patients above 90 kg no. 5 LMU was inserted by an anesthetist with more than five years experience. The placement method was according to the manufacturer's instructions. All patients were respirated by a breathing circuit with heat and moisture filter.

After the laryngeal mask was inserted the cases were manually respirated so peak inspiratory pressure was less than 20 cmH2O and the cuff of both groups was inflated with a 20 ml injector until the leak sound ceased. To evaluate ventilation the capnogram showed square wave forms and the patients' chest movements were observed, in unsuccessful situations the procedure was repeated. During attempts depending on the patients' reactions and with the requirement of keeping BIS values between 40 and 60, an additional dose of 0.5 mg/kg propofol was administered.

After Laryngeal Mask was determined and when anesthetic depth was sufficient (BIS 40-60) the inner pressure of the LMU cuff was measured and recorded by a manometer (cuff pressure manometer, Rusch, Germany). Later groups were divided in two using a random number table. In the group with cuff pressure limitation (Group Pressure Limiting (PL), n=45) cuff inner pressure was held below 60 cmH2O (44 mmHg), while the routine group (Group Routine Care, n=45) pressure was only recorded.

Anesthesia was maintained by 50% O2:50% air mix with 1.5-2.5% sevoflurane, with sevoflurane concentration and additional fentanyl doses arranged to keep BIS between 40 and 60. All patients were respirated with positive pressure ventilation tidal volume 7-8 ml/kg, inspiring: expiring rate 1:2, respiration frequency on the capnograph end tidal carbon dioxide held between 30-35 mmHg. Oropharyngeal leak pressure measurement was recorded as the pressure value when a leak sound was heard from the mouth after the expiring valve was closed and fresh gas flow was reduced to 3 L/min. Immediately after the laryngeal mask was inserted, every 5 minutes in the first half hour and every 15 minutes after that, tidal volume, mean airway pressure, end tidal carbon dioxide levels and peripheral oxygen saturation values were recorded. If the operation lasted more than one hour a second manometric measurement was taken and stable values were maintained.

After the operation, the LMU's were removed when the patients were awake and could open their mouths on an oral command and unless necessary, aspiration was not applied.After anesthesia the patients were monitored in the recovery unit and analgesia was provided by 5-10 mg intravenous dolantin titration. A researcher blind to the groups recorded throat pain, voice loss and difficulty swallowing in the 1st and 24th hour, classifying as Likert scale ranges from 1 (none) to 4 (severe). Cases developing rare complications of recurrent laryngeal nerve, hypoglossal nerve and lingual nerve paralysis were recorded. The cases were brought to the ward when Aldrete scoring criteria were appropriate. Cases discharged early from the ward had 24th hour evaluation by telephone communication.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

90

Phase

  • Phase 4

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Izmi̇r, Truthahn, 35320
        • Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

65 Jahre und älter (Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Above the age of 65
  • ASA I-III
  • Undergoing elective surgery

Exclusion Criteria:

  • Patients with recent history of upper respiratory infection
  • Obese patients with body-mass index above 35 kg/m2
  • Symptomatic hiatus hernia
  • Severe gastroesophageal reflux
  • Dementia

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Screening
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: Group Routine Care
The placement according to the manufacturer's instructions.
Before insertion the laryngeal mask used in daily routine (Laryngeal Mask Unique®(LMU)) was lubricated with a water-based gel and the cuff was completely deflated. After induction when BIS values were between 40 and 60 and sufficient chin relaxation was obtained for patients weighing less than 50 kg no. 3 LMU, for those between 50-90 kg no. 4 and for patients above 90 kg no. 5 LMU was inserted by an anesthetist with more than five years experience
Experimental: Group Pressure Limiting
Cuff inner pressure was held below 44 mmHg
cuff pressure limitation (Group Pressure Limiting (PL), n=45) cuff inner pressure was held below 60 cmH2O (44 mmHg)

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Postoperative Pharyngolaryngeal Morbidity Postoperative 1.Hour
Zeitfenster: Postoperative 1.hour
The primary outcome was a composite endpoint of any pharyngolaryngeal complications such as sore throat, dysphonia and dysphagia according to Likert scale ranges from 1 (none) to 4 (severe) at postoperative 1.hour
Postoperative 1.hour

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Postoperative Pharyngolaryngeal Morbidity at Postoperative 24.Hour
Zeitfenster: Postoperative 24.hour
The primer outcome was a composite endpoint of any pharyngolaryngeal complications such as sore throat, dysphonia and dysphagia according to Likert scale ranges from 1 (none) to 4 (severe) at postoperative 24.hour
Postoperative 24.hour

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: FERİM GÜNENÇ, M.D., Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn

1. Juli 2011

Primärer Abschluss (Tatsächlich)

1. Juli 2012

Studienabschluss (Tatsächlich)

1. August 2012

Studienanmeldedaten

Zuerst eingereicht

28. Juni 2014

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

11. Juli 2014

Zuerst gepostet (Schätzen)

15. Juli 2014

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Schätzen)

31. August 2015

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

5. August 2015

Zuletzt verifiziert

1. August 2015

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 269-GOA

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur The placement according to the manufacturer's instructions

Abonnieren