Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

An Evaluation Of The Fitting Success Rate Of Senofilcon A Soft Contact Lenses In Three Designs.

6. Juni 2018 aktualisiert von: Graeme Young
This study will compare the on-eye fitting characteristics of three types of contact lenses. Each lens pair will be worn for 30 to 45 minutes before assessment and the results will be compared to mathematically calculated fitting characteristics.

Studienübersicht

Detaillierte Beschreibung

This will be an approx. 40-60 subject, one-day, double-masked, randomised, repeated measures study. Each subject will wear the three lens types bilaterally in random succession, a total of six lenses will therefore be worn by each subject (3 per eye).

Studientyp

Interventionell

Einschreibung (Tatsächlich)

51

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Surrey
      • Farnham, Surrey, Vereinigtes Königreich, GU9 7EN
        • Visioncare research
    • West Midlands
      • Birmingham, West Midlands, Vereinigtes Königreich, B4 7ET
        • Aston University Optometry Clinic

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 70 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Age 18-70 years.
  • Able to read, comprehend and sign an informed consent.
  • Willing to comply with the wear and study assessment schedule.
  • Spherical distance prescription between -0.50 and -6.00 (inc.).
  • Astigmatism, if present,≤1.50DC in both eyes.
  • Have normal eyes with no evidence of any ocular abnormality or disease. For the purposes of this study a normal eye is defined as one having:

A clear central cornea. No anterior segment disorders. No clinically significant slit lamp findings (i.e. corneal oedema, significant staining, central scarring, infiltrates, active neovascularisation). No other active ocular disease (including pterygia).

Exclusion Criteria:

  • Previous anterior ocular surgery
  • Any active corneal infection, injury or inflammation

    . •Large pinguecula likely to affect soft lens fit

  • Systemic or ocular disease or medication which might interfere with CL wear
  • Pregnancy or breastfeeding
  • Participation in any concurrent trial

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Nicht randomisiert
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Single

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: First Pair Senofilcon A contact lens
The first pair of Senofilcon A contact lenses is applied (according to the fitting schedule), allowed to settle before assessment of the first pair Senofilcon A contact lens and subsequent removal.
Fit assessment of the first pair contact lenses.
Aktiver Komparator: Second pair Senofilcon A contact lens
The second pair of contact lenses is applied (according to the fitting schedule), allowed to settle before assessment of the second pair Senofilcon A contact lens and subsequent removal.
Fit assessment of the second pair of contact lenses.
Aktiver Komparator: Third pair Senofilcon A contact lens
The third pair of Senofilcon A contact lens is applied (according to the fitting schedule), allowed to settle before assessment of the third pair Senofilcon A contact lens and subsequent removal.
Fit assessment of the third pair of contact lenses.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Lens fit (position on the eye) in mm
Zeitfenster: 25 minutes
Horizontal Lens Centration (mm), Vertical Lens Centration (mm), Post-blink movement in primary gaze (mm), Version lag (mm), Horizontal corneal overlap (mm), Diameter acceptance (mm),
25 minutes
Lens edge tightness fit grade 0-4
Zeitfenster: 5 minutes
Edge tightness (grade 0-4)
5 minutes
Lens tightness fit graded as %
Zeitfenster: 5 minutes
Tightness (push-up %),
5 minutes
Lens overall fit grade 0-5
Zeitfenster: 5 minutes
Overall fit acceptability (Grade 0-5),
5 minutes

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Studienleiter: Graeme Young, PhD MPhil, Managing Director

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

26. Januar 2018

Primärer Abschluss (Tatsächlich)

24. Mai 2018

Studienabschluss (Tatsächlich)

24. Mai 2018

Studienanmeldedaten

Zuerst eingereicht

8. Dezember 2017

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

19. Dezember 2017

Zuerst gepostet (Tatsächlich)

27. Dezember 2017

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

7. Juni 2018

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

6. Juni 2018

Zuletzt verifiziert

1. April 2018

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Schlüsselwörter

Andere Studien-ID-Nummern

  • TRTN-501

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren