- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT04919291
Direct Comparison of TG and WFO LASIK
Contralateral Comparison of Togoguided LASIK and Wavefront-optimized LASIK
To compare the efficacy to different profiles, direct head-to-head studies had been conducted. In one previous review study revealed that TG LASIK provided patient with better uncorrected visual acuity (UCVA) than WFO LASIK and WFG LASIK. In recent previous contralateral eye studies also showed that TG LASIK induced less postoperative higher-order aberration than WFO LASIK. However, these studies included only low-to-moderate myopia patients, for patients with high myopia (spherical equivalent > 6D), the effect of TG LASIK comparing with WFO LASIK had not been reported before.
The aim of our study is to analyze and compare the visual performance of TG LASIK and WFO LASIK in high myopia and low-to-moderate myopia patients, , particularly UCVA, corrected distance visual acuity (CDVA), contrast sensitivity (CS), and wavefront aberration.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Taipei, Taiwan
- Taipei Nobel Eye Clinic
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- age between 20 and 50 years old
- CDVA of both eyes could reach 0.1 logarithm of the minimum angle of resolution (logMAR)
- stable refractive errors of myopia and astigmatism
Exclusion Criteria:
- cataract
- corneal opacities or irregularities
- dry eye (Schirmer's test I ≤ 5mm)
- amblyopia
- coexisting ocular pathologies
- glaucoma
- non-dilating pupil
- history of intraocular surgery, laser therapy, or retinopathy
- optic nerve or macular diseases
- estimated postoperative cornea residual stromal thickness less than 250 μm
- pregnancy or under lactation
- uncontrolled diabetic mellitus or systemic immune disease
- refusal or unable to maintain follow-up
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Nicht randomisiert
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Aktiver Komparator: Topoguided LASIK
Topoguided ablation profile on dominant eye
|
Topoguided ablation profile on dominant eye
|
|
Aktiver Komparator: Wavefront optimized LASIK
Wavefront optimized ablation profile on non-dominant eye
|
Wavefront optimized ablation profile on non-dominant eye
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Visual acuity
Zeitfenster: 3 months after surgery
|
uncorrected visual acuity and corrected distance visual acuity
|
3 months after surgery
|
|
Corneal wavefront analysis
Zeitfenster: 3-months postoperative visit
|
horizontal coma aberration (Z 3,1), spherical aberration (Z 4,0), and trefoil aberration
|
3-months postoperative visit
|
|
Contrast sensitivity
Zeitfenster: 3-months postoperative visit
|
4 spatial frequencies: 3, 6, 12, and 18 cycles per degree (cpd).
|
3-months postoperative visit
|
|
Quality of vision questionnaire
Zeitfenster: 3-months postoperative visit
|
A 11-item questionnaire, item scores range from 0 to 10 and higher item scores in questionnaire indicated more difficulty in achieving specific visual tasks
|
3-months postoperative visit
|
Mitarbeiter und Ermittler
Sponsor
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Sutton G, Lawless M, Hodge C. Laser in situ keratomileusis in 2012: a review. Clin Exp Optom. 2014 Jan;97(1):18-29. doi: 10.1111/cxo.12075. Epub 2013 Jun 21. Review.
- Moreno-Barriuso E, Lloves JM, Marcos S, Navarro R, Llorente L, Barbero S. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci. 2001 May;42(6):1396-403.
- Schallhorn SC, Farjo AA, Huang D, Boxer Wachler BS, Trattler WB, Tanzer DJ, Majmudar PA, Sugar A; American Academy of Ophthalmology. Wavefront-guided LASIK for the correction of primary myopia and astigmatism a report by the American Academy of Ophthalmology. Ophthalmology. 2008 Jul;115(7):1249-61. doi: 10.1016/j.ophtha.2008.04.010.
- Stonecipher K, Parrish J, Stonecipher M. Comparing wavefront-optimized, wavefront-guided and topography-guided laser vision correction: clinical outcomes using an objective decision tree. Curr Opin Ophthalmol. 2018 Jul;29(4):277-285. doi: 10.1097/ICU.0000000000000495. Review.
- Kim J, Choi SH, Lim DH, Yang CM, Yoon GJ, Chung TY. Topography-guided versus wavefront-optimized laser in situ keratomileusis for myopia: Surgical outcomes. J Cataract Refract Surg. 2019 Jul;45(7):959-965. doi: 10.1016/j.jcrs.2019.01.031. Epub 2019 Jun 10.
- Kim J, Choi SH, Lim DH, Yoon GJ, Chung TY. Comparison of outcomes after topography-modified refraction versus wavefront-optimized versus manifest topography-guided LASIK. BMC Ophthalmol. 2020 May 14;20(1):192. doi: 10.1186/s12886-020-01459-0. Erratum in: BMC Ophthalmol. 2020 Dec 29;20(1):492.
- Ozulken K, Yuksel E, Tekin K, Kiziltoprak H, Aydogan S. Comparison of Wavefront-Optimized Ablation and Topography-Guided Contoura Ablation With LYRA Protocol in LASIK. J Refract Surg. 2019 Apr 1;35(4):222-229. doi: 10.3928/1081597X-20190304-02.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 002 (University of CT Health Center)
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .