Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Influence of Provisional Restoration Type on Outcomes of Immediate Implant Placement and Loading (PRODIGI)

8. Juli 2026 aktualisiert von: Mansoura University

Influence of Provisional Restoration Type on Clinical Outcomes of Fully Digital Single-Visit Immediate Implant Placement and Loading: A Randomized Clinical Trial

A randomized clinical trial comparing 3D-printed resin and CAD/CAM-milled PMMA provisional restorations used for immediate loading of fully digitally guided immediate implants.

Studienübersicht

Detaillierte Beschreibung

Sixty patients were randomly allocated to receive either a 3D-printed resin or a CAD/CAM-milled PMMA provisional crown used for immediate loading after fully digitally guided immediate implant placement in the maxillary esthetic zone. Clinical and peri-implant soft tissue outcomes will be evaluated.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

60

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, Ägypten
        • Faculty of Dentistry Mansoura University

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • 1. Patients presenting with non-restorable teeth in the maxillary esthetic zone indicated for extraction and immediate implant placement.

    2. Age ranging from 18 to 50 years. 3. Adequate interarch relationship and interocclusal space to accommodate the planned prosthetic restoration.

    4. Intact extraction socket walls with a jumping gap not exceeding 4 mm, as measured on preoperative CBCT images. The jumping gap will be defined as the horizontal distance between the implant surface and the inner aspect of the buccal socket wall and will be grafted in all cases.

    5. Good oral hygiene and periodontal health. 6. Willingness to attend all follow-up visits and comply with study requirements.

Exclusion Criteria:

  • 1. Presence of acute infection, pathological lesions, or severe periodontal disease at the planned implant site.

    2. Smokers. 3. Alcohol or drug abuse. 4. Patients with systemic conditions contraindicating implant surgery (e.g., uncontrolled diabetes mellitus, bleeding disorders, immunosuppression, recent radiotherapy to the head and neck region).

    5. Pregnancy or lactation. 6. Patients with parafunctional habits such as bruxism or clenching. 7. Inability to maintain adequate oral hygiene or attend follow-up visits.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Study Group 1 (3D-Printed resin Group)
Thirty patients received a digitally designed 3D-printed resin immediate provisional crown for immediate loading, serving as a customized healing abutment following fully guided immediate implant placementin the maxillary esthetic zone.
A digitally designed and 3D-printed resin immediate provisional crown was delivered immediately after fully guided implant placement in the maxillary esthetic zone and served as a customized healing abutment.
Experimental: Study Group 2 (CAD/CAM-Milled PMMA Group)
Thirty patients received a digitally designed CAD/CAM-milled PMMA immediate provisional crown for immediate loading, serving as a customized healing abutment following fully guided immediate implant placement in the maxillary esthetic zone.
A digitally designed CAD/CAM-milled PMMA immediate provisional crown was delivered immediately after fully guided implant placement in the maxillary esthetic zone and served as a customized healing abutment.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Peri-implant soft tissue changes
Zeitfenster: Baseline (immediately after provisionalization), 1 month, 3 months, and 6 months postoperatively.
Soft tissue contour and peri-implant tissue condition will be assessed using digital intraoral scanning (STL files) using superimposition.
Baseline (immediately after provisionalization), 1 month, 3 months, and 6 months postoperatively.

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Pink Esthetic Score (PES)
Zeitfenster: After 3 and 6 months postoperatively.
Peri-implant soft tissue esthetics were assessed using the Pink Esthetic Score (0-14). Higher scores indicated better esthetic outcomes.
After 3 and 6 months postoperatively.
Implant stability
Zeitfenster: Immediate post-operative and at 3 months.
Implant stability will be evaluated using Osstell device based on resonance frequency analysis (ISQ values).
Immediate post-operative and at 3 months.

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

1. Dezember 2025

Primärer Abschluss (Tatsächlich)

30. Juni 2026

Studienabschluss (Geschätzt)

1. Juli 2026

Studienanmeldedaten

Zuerst eingereicht

8. Juli 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

8. Juli 2026

Zuerst gepostet (Tatsächlich)

14. Juli 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

14. Juli 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

8. Juli 2026

Zuletzt verifiziert

1. Juli 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

3
Abonnieren