Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Influence of Provisional Restoration Type on Outcomes of Immediate Implant Placement and Loading (PRODIGI)

21 de julho de 2026 atualizado por: Mansoura University

Influence of Provisional Restoration Type on Clinical Outcomes of Fully Digital Single-Visit Immediate Implant Placement and Loading: A Randomized Clinical Trial

A randomized clinical trial comparing 3D-printed resin and CAD/CAM-milled PMMA provisional restorations used for immediate loading of fully digitally guided immediate implants.

Visão geral do estudo

Descrição detalhada

Sixty patients were randomly allocated to receive either a 3D-printed resin or a CAD/CAM-milled PMMA provisional crown used for immediate loading after fully digitally guided immediate implant placement in the maxillary esthetic zone. Clinical and peri-implant soft tissue outcomes will be evaluated.

Tipo de estudo

Intervencional

Inscrição (Real)

60

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, Egito
        • Faculty of Dentistry Mansoura University

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Patients presenting with non-restorable teeth in the maxillary esthetic zone indicated for extraction and immediate implant placement.
  • Age ranging from 18 to 50 years.
  • Adequate interarch relationship and interocclusal space to accommodate the planned prosthetic restoration.
  • Intact extraction socket walls with a jumping gap not exceeding 4 mm, as measured on preoperative CBCT images. The jumping gap will be defined as the horizontal distance between the implant surface and the inner aspect of the buccal socket wall and will be grafted in all cases.
  • Good oral hygiene and periodontal health.
  • Willingness to attend all follow-up visits and comply with study requirements.

Exclusion Criteria:

  • Presence of acute infection, pathological lesions, or severe periodontal disease at the planned implant site.
  • Smokers.
  • Alcohol or drug abuse.
  • Patients with systemic conditions contraindicating implant surgery (e.g., uncontrolled diabetes mellitus, bleeding disorders, immunosuppression, recent radiotherapy to the head and neck region).
  • Pregnancy or lactation.
  • Patients with parafunctional habits such as bruxism or clenching.
  • Inability to maintain adequate oral hygiene or attend follow-up visits.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Study Group 2 (CAD/CAM-Milled PMMA Group)
Thirty patients received a digitally designed CAD/CAM-milled PMMA immediate provisional crown for immediate loading, serving as a customized healing abutment following fully guided immediate implant placement in the maxillary esthetic zone.
A digitally designed CAD/CAM-milled PMMA immediate provisional crown was delivered immediately after fully guided implant placement in the maxillary esthetic zone and served as a customized healing abutment.
Experimental: Study Group 1 (3D-Printed resin Group)
Thirty patients received a digitally designed 3D-printed resin immediate provisional crown for immediate loading, serving as a customized healing abutment following fully guided immediate implant placement in the maxillary esthetic zone.
A digitally designed and 3D-printed resin immediate provisional crown was delivered immediately after fully guided implant placement in the maxillary esthetic zone and served as a customized healing abutment.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Peri-implant soft tissue changes
Prazo: Baseline (immediately after provisionalization), 1 month, 3 months, and 6 months postoperatively.
Soft tissue contour and peri-implant tissue condition will be assessed using digital intraoral scanning (STL files) using superimposition.
Baseline (immediately after provisionalization), 1 month, 3 months, and 6 months postoperatively.

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Pink Esthetic Score (PES)
Prazo: After 3 and 6 months postoperatively.
Peri-implant soft tissue esthetics were assessed using the Pink Esthetic Score (0-14). Higher scores indicated better esthetic outcomes.
After 3 and 6 months postoperatively.
Implant stability
Prazo: Immediate post-operative and at 3 months.
Implant stability will be evaluated using Osstell device based on resonance frequency analysis (ISQ values).
Immediate post-operative and at 3 months.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de dezembro de 2025

Conclusão Primária (Real)

30 de junho de 2026

Conclusão do estudo (Estimado)

1 de julho de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

8 de julho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

8 de julho de 2026

Primeira postagem (Real)

14 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

22 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

21 de julho de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever