First Attempt Insertion Success of Novel Two Person Lateral Rotation Technique V.S Standard Brain Technique for LMA Insertion (LMA insertion)
First-Attempt Insertion Success of a Novel Two-Person Lateral Rotation Technique Versus the Standard Brain Technique for Laryngeal Mask Airway Placement: A Randomized Controlled Trial
The goal of this clinical trial is to learn if two person lateral rotation technique of LMA insertion is more successful than the standard technique in achieving effective ventilation on the first introduction of the LMA .The main questions it aims to answer are:
Does two person lateral rotation technique of LMA insertion lower the number of times needed to inesrt the LMA ?
Researchers will compare two person lateral rotation technique of LMA insertion to standard technique to see if it is more successful
Participants will be subjected to the two way of LMA insertion
Studienübersicht
Status
Intervention / Behandlung
Studientyp
Einschreibung (Geschätzt)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Banhā, Ägypten
- Benha University Hospital
-
Kontakt:
- Taghreed Sakr, MD degree of anesthesia
- Telefonnummer: 00201112723187
- E-Mail: taghreed.sakr@fmed.bu.edu.eg
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Beschreibung
Inclusion Criteria:
- Adult patients aged 18-65 years
- American Society of Anesthesiologists (ASA) physical status I-II
- Scheduled for elective superficial surgical procedures under general anesthesia (e.g., limb orthopedic surgery, hernioplasty, soft tissue excision)
- Anticipated surgical duration < 90 minutes
- Body mass index (BMI) 18.5-30 kg/m²
Exclusion Criteria:
- - Anticipated difficult airway (Mallampati grade IV, thyromental distance < 6 cm, limited neck extension)
- History of gastroesophageal reflux disease or increased aspiration risk
- Full stomach or emergency surgery - Intra-abdominal, laparoscopic, head and neck, or prone-position procedures - Known allergy to anesthetic agents
- Pregnancy
- Previous pharyngeal or laryngeal surgery - Inability to provide informed consent
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Unterstützende Pflege
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Placebo-Komparator: standard group
stanedred LMA insertion
|
Standard Brain Technique for Laryngeal Mask Airway Placement
|
|
Aktiver Komparator: 2 persons group
2 person lateral rotation LMA insertion
|
Novel Two-Person Lateral Rotation Technique of LMA insertion
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
First-attempt insertion success rate, defined as successful placement achieving effective ventilation on the first introduction of the LMA into the oral cavity
Zeitfenster: 1 minute after LMA insertion
|
1 minute after LMA insertion
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Insertion time
Zeitfenster: 20-90 seconds from picking up the LMA to be inserted in the mouth
|
Interval from picking up the LMA to confirmation of effective ventilation (square-wave capnogram, no audible leak at 20 cmH₂O, normal chest movement)
|
20-90 seconds from picking up the LMA to be inserted in the mouth
|
|
Number of attempts
Zeitfenster: 2-3 minutes after induction of anesthesia
|
Recorded up to a maximum of three; failure defined as inability to achieve effective ventilation after three attempts
|
2-3 minutes after induction of anesthesia
|
|
Need for manipulations
Zeitfenster: 1-2 minutes after induction of anesthesia
|
Chin lift, jaw thrust, head extension, neck flexion, or moderate advancement recorded as binary
|
1-2 minutes after induction of anesthesia
|
|
Oropharyngeal leak pressure (OLP)
Zeitfenster: 1-2 minutes after insertion of LMA
|
Measured by closing the expiratory valve at a constant gas flow of 3 L/min with the upper pressure limit set to 30 cmH₂O; the pressure at which an audible leak is detected is recorded
|
1-2 minutes after insertion of LMA
|
|
Complications:
Zeitfenster: immediate after removal of LMA ,1,2,4,24 hours. post operative
|
Blood staining on LMA (indicating mucosal trauma), sore throat (assessed postoperatively using a 4-point verbal rating scale), laryngospasm, hypoxia (SpO₂ < 92%), and gastric insufflation (detected by epigastric auscultation)
|
immediate after removal of LMA ,1,2,4,24 hours. post operative
|
Mitarbeiter und Ermittler
Sponsor
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Geschätzt)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- RC.14.5.2026
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .