Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Comparison of Echocardiographic Techniques in Diagnosis of Coronary Artery Disease

3 de marzo de 2008 actualizado por: National Heart, Lung, and Blood Institute (NHLBI)

Comparison of Myocardial Contrast Echo With Dobutamine Echo in Diagnosis of Coronary Artery Disease

This study is designed to compare two different echocardiographic techniques in the evaluation of heart disease (coronary artery disease). Both tests called Myocardial Contrast Echocardiography with Pharmacologic Stress and Stress Echocardiography with Dobutamine, are performed using a standard echocardiographic machine.

Myocardial Contrast Echocardiography (MCE) does not use radioactivity. It uses sound waves like standard echocardiography. However, with MCE patients receive an injection of a "contrast agent" directly into the blood stream through a vein. The contrast agent, called Optison, is made of tiny microbubbles smaller than red blood cells. The echocardiogram can detect these microbubbles in the small blood vessels of the heart muscle and allow researchers to find areas of the heart receiving less blood flow than others. It is important to observe the heart during exercise because there are changes in blood flow. Since MCE cannot be performed when the patient is exercising, researchers give medication (adenosine) that stimulates the heart and creates a situation similar to exercise.

Stress Echocardiography with Dobutamine does not use radioactivity. It uses sound waves like standard echocardiography. During this echocardiogram patients receive doses of a medication called dobutamine that stimulates the heart to beat stronger and faster.

The purpose of this study is to evaluate the accuracy of MCE compared to stress echocardiography at detecting coronary artery disease (CAD).

Descripción general del estudio

Descripción detallada

Stress echocardiography has become a valuable technique for the non-invasive detection of coronary artery disease (CAD). Its accuracy has been shown to be superior to that of the exercise electrocardiogram and comparable to that of myocardial perfusion imaging. Myocardial contrast echocardiography (MCE) offers the potential to evaluate tissue perfusion at the level where oxygen transfer to the myocytes occurs. MCE can, therefore, provide information regarding the functional status of the myocardial microvasculature and presence of blood flow disparity. The purpose of this study is to evaluate the accuracy of MCE compared to stress echocardiography. We will correlate these results with findings from coronary angiography and compare the ability of those techniques to detect CAD.

Tipo de estudio

Intervencionista

Inscripción

150

Fase

  • Fase 2

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Maryland
      • Bethesda, Maryland, Estados Unidos, 20892
        • National Heart, Lung and Blood Institute (NHLBI)

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Niño
  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Patients with known or suspected coronary artery disease.

Adults 18 years of age or older.

No pre-menopausal patients who are lactating, pregnant or potentially pregnant as judged by history, physical examination, ultrasound or urine pregnancy test.

No unstable angina patients.

No recent myocardial infarction patients (less than 1 month).

No frequent ectopy which precludes adequate image acquisition.

No history of asthma or chronic obstructive pulmonary disease.

No patients receiving aminophylline, theophylline or dipyridamole.

No presence of second and third degree heart block without pacemaker.

No significant hypertension (systolic blood pressure greater than 170 mm Hg) or hypotension (systolic blood pressure less than 100 mm Hg).

No hypotension: basal sitting systolic arterial pressure less than 100 mm Hg confirmed 30 minutes later.

No sinus tachycardia greater than or equal to 100 beats per min.

No atrial fibrillation.

No inadequate two-dimensional echocardiographic windows.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de marzo de 1999

Finalización del estudio

1 de marzo de 2001

Fechas de registro del estudio

Enviado por primera vez

3 de noviembre de 1999

Primero enviado que cumplió con los criterios de control de calidad

9 de diciembre de 2002

Publicado por primera vez (Estimar)

10 de diciembre de 2002

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

4 de marzo de 2008

Última actualización enviada que cumplió con los criterios de control de calidad

3 de marzo de 2008

Última verificación

1 de febrero de 2000

Más información

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Ensayos clínicos sobre Ecocardiografía miocárdica de contraste

3
Suscribir