Optimal Flow Rate During Cardiopulmonary Bypass
Regardless of the development of cardiac surgery techniques and technologies, the question of an optimal extracorporeal circulation is still unanswered. There are globally accepted standards of perfusion, however, keep many of these procedures was not evidence-based review.
Generally accepted are flow rates during cardiopulmonary bypasses of 2.5 L/min/m2. This target was derived from the physiological conditions, but they are not the result of an adapted adjustment to the fundamentally non-physiological processes during extracorporeal circulation. Among other things, an increased metabolic demand during re-perfusion is not taken into account.
An increasing and optimizing of the standard flow rate of 0.5 L/min/m2 should be the aim of this investigation. Under optimal perfusion, the investigators are maintaining the microcirculation and organ protection in receipt of endothelial function and oxygen transport.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción (Anticipado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Frankfurt am Main, Alemania, 60590
- Reclutamiento
- Johann Wolfgang Goethe University Hospital
-
Contacto:
- Arndt H Kiessling, MD
- Número de teléfono: 6705 +49696301
- Correo electrónico: arndt.kiessling@kgu.de
-
Sub-Investigador:
- Arndt H Kiessling, MD
-
Sub-Investigador:
- Eduard Manherz
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Extracorporeal circulation
- Age > 18
- Written consent
Exclusion Criteria:
- Emergency cases
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Otro: Flow rate
Comparison between a flow rate of 2.5/l/min/m2 versus 3.0/l/min/m2
|
Different flow rate during cardiopulmonary bypass
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Microcirulation
Periodo de tiempo: intraooperative
|
measurement with O2C
|
intraooperative
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Otros números de identificación del estudio
- CI001AZ-AHK
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .