- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT01426217
Reduction in IV Associated Contamination
20 de septiembre de 2018 actualizado por: Dartmouth-Hitchcock Medical Center
Reduction in Intraoperative Lumen Contamination of Standard 3-Way Open Lumen Stopcock Sets Through Use of a Novel, Passive Bundle
The purpose of this study is to investigate whether implementing a novel syringe and IV stopcock cap system impregnated with alcohol will reduce IV catheter bacterial contamination and infections in patients.
Descripción general del estudio
Estado
Terminado
Condiciones
Intervención / Tratamiento
Descripción detallada
Bacterial contamination of patient intravenous stopcock sets is a common intraoperative event associated with increased patient mortality, possibly via an infectious mechanism.
The most common type of intravenous tubing used in operating rooms is the open lumen stopcock set which lacks a barrier between the environment and intraluminal space, and thus the intravascular space of the patient.
The stopcock connector can be easily contaminated by provider hands due to improper handling of the device and/or contaminated by soiled syringe tips subsequently connected to the device.
Further, the stopcock connector is often left uncapped by the provider and directly exposed to the environment.
Thus, common breaches in intraoperative aseptic practice of healthcare providers can lead to bacterial contamination of the endoluminal space of the open lumen device.
The primary aim of the current study is to assess the efficacy of a passive bundle designed to decrease intravenous stopcock and tubing intraluminal bacterial contamination.
This passive bundle includes two novel interventions, a DOCit station and HubScrub caps.
The HubScrub is designed to clean the needleless connectors and open lumen stopcock systems.
The DOCit station is designed to simultaneously clean the interior and exterior of needle-less luer connectors of syringes with isopropyl alcohol while also providing a method of storage and organization of multiple syringes.
The investigators hypothesize that the application of this passive bundle to the standard open lumen system commonly employed by anesthesia providers in the operating room will significantly reduce bacterial contamination of standard 3-way open lumen stopcock sets and improve patient safety.
Tipo de estudio
Intervencionista
Inscripción (Actual)
594
Fase
- No aplica
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
New Hampshire
-
Lebanon, New Hampshire, Estados Unidos, 03756
- Dartmouth-Hitchcock Medical Center
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
18 años y mayores (Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Descripción
Inclusion Criteria:
- Adult patient undergoing surgery or procedure in operating room
- Undergoing general anesthesia
Exclusion Criteria:
- Children (age < 18 years)
- Lack of intravenous access
- failure of anesthesia provider to complete training on experimental device
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Prevención
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Único
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Sin intervención: Control
Control arm using standard of care operating room procedures and equipment
|
|
|
Experimental: Problem Solving Innovations (PSI) Experimental
Implementation of the passive bundle including HubScrub and DocIt
|
Implementation of passive bundle which includes HubScrub and DocIt device into the operating room environment.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Presence of Bacterial IV Stopcock Lumen Contamination
Periodo de tiempo: 48 hours
|
The presence of bacteria in the stopcock lumen was assessed by analyzing swab cultures of the lumens.
Each swab potentially containing bacteria from any of the 3 lumens of the stopcock sets were analyzed
|
48 hours
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Presence of Positive Bacterial Culture in IV Stopcock Due to Effluent Contamination
Periodo de tiempo: Until positive, up to 5 days
|
Open lumen ports were removed from the patient; sent directly to the anesthesiology microbiology laboratory; connected by the same clinical laboratory scientist to sterile catheters using sterile, aseptic technique; and injected directly into a BacT/Alert 3D system (bioMérieux Inc., Durham, NC) with 2 mL of sterile saline per port.
BacT/Alert is a blood culture system that automatically monitors bacterial growth using colorimetry; a sensor inserted at the bottom of the bottle changes color on detecting the carbon dioxide produced by the growth of the bacteria.
Catheters were then removed, and the bottles were directly incubated in the BacT/Alert system for 5 days or until positive.
Once positive, the liquid in the bottle was examined to identify the organism.
|
Until positive, up to 5 days
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Bryan S Brindeiro, MD, Dartmouth-Hitchcock Medical Center
- Director de estudio: Randy W Loftus, MD, Dartmouth-Hitchcock Medical Center
Publicaciones y enlaces útiles
La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.
Publicaciones Generales
- Loftus RW, Koff MD, Burchman CC, Schwartzman JD, Thorum V, Read ME, Wood TA, Beach ML. Transmission of pathogenic bacterial organisms in the anesthesia work area. Anesthesiology. 2008 Sep;109(3):399-407. doi: 10.1097/ALN.0b013e318182c855.
- Koff MD, Loftus RW, Burchman CC, Schwartzman JD, Read ME, Henry ES, Beach ML. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device. Anesthesiology. 2009 May;110(5):978-85. doi: 10.1097/ALN.0b013e3181a06ec3.
- Loftus RW, Muffly MK, Brown JR, Beach ML, Koff MD, Corwin HL, Surgenor SD, Kirkland KB, Yeager MP. Hand contamination of anesthesia providers is an important risk factor for intraoperative bacterial transmission. Anesth Analg. 2011 Jan;112(1):98-105. doi: 10.1213/ANE.0b013e3181e7ce18. Epub 2010 Aug 4.
- Loftus RW, Brindeiro BS, Kispert DP, Patel HM, Koff MD, Jensen JT, Dodds TM, Yeager MP, Ruoff KL, Gallagher JD, Beach ML, Brown JR. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a passive catheter care system. Anesth Analg. 2012 Dec;115(6):1315-23. doi: 10.1213/ANE.0b013e31826d2aa4. Epub 2012 Nov 9.
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio
1 de agosto de 2011
Finalización primaria (Actual)
1 de noviembre de 2011
Finalización del estudio (Actual)
1 de noviembre de 2011
Fechas de registro del estudio
Enviado por primera vez
29 de agosto de 2011
Primero enviado que cumplió con los criterios de control de calidad
30 de agosto de 2011
Publicado por primera vez (Estimar)
31 de agosto de 2011
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
18 de octubre de 2018
Última actualización enviada que cumplió con los criterios de control de calidad
20 de septiembre de 2018
Última verificación
1 de agosto de 2018
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 22743
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .