Reduction in IV Associated Contamination
20 de setembro de 2018 atualizado por: Dartmouth-Hitchcock Medical Center
Reduction in Intraoperative Lumen Contamination of Standard 3-Way Open Lumen Stopcock Sets Through Use of a Novel, Passive Bundle
The purpose of this study is to investigate whether implementing a novel syringe and IV stopcock cap system impregnated with alcohol will reduce IV catheter bacterial contamination and infections in patients.
Visão geral do estudo
Status
Concluído
Condições
Intervenção / Tratamento
Descrição detalhada
Bacterial contamination of patient intravenous stopcock sets is a common intraoperative event associated with increased patient mortality, possibly via an infectious mechanism.
The most common type of intravenous tubing used in operating rooms is the open lumen stopcock set which lacks a barrier between the environment and intraluminal space, and thus the intravascular space of the patient.
The stopcock connector can be easily contaminated by provider hands due to improper handling of the device and/or contaminated by soiled syringe tips subsequently connected to the device.
Further, the stopcock connector is often left uncapped by the provider and directly exposed to the environment.
Thus, common breaches in intraoperative aseptic practice of healthcare providers can lead to bacterial contamination of the endoluminal space of the open lumen device.
The primary aim of the current study is to assess the efficacy of a passive bundle designed to decrease intravenous stopcock and tubing intraluminal bacterial contamination.
This passive bundle includes two novel interventions, a DOCit station and HubScrub caps.
The HubScrub is designed to clean the needleless connectors and open lumen stopcock systems.
The DOCit station is designed to simultaneously clean the interior and exterior of needle-less luer connectors of syringes with isopropyl alcohol while also providing a method of storage and organization of multiple syringes.
The investigators hypothesize that the application of this passive bundle to the standard open lumen system commonly employed by anesthesia providers in the operating room will significantly reduce bacterial contamination of standard 3-way open lumen stopcock sets and improve patient safety.
Tipo de estudo
Intervencional
Inscrição (Real)
594
Estágio
- Não aplicável
Contactos e Locais
Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.
Locais de estudo
-
-
New Hampshire
-
Lebanon, New Hampshire, Estados Unidos, 03756
- Dartmouth-Hitchcock Medical Center
-
-
Critérios de participação
Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.
Critérios de elegibilidade
Idades elegíveis para estudo
18 anos e mais velhos (Adulto, Adulto mais velho)
Aceita Voluntários Saudáveis
Não
Gêneros Elegíveis para o Estudo
Tudo
Descrição
Inclusion Criteria:
- Adult patient undergoing surgery or procedure in operating room
- Undergoing general anesthesia
Exclusion Criteria:
- Children (age < 18 years)
- Lack of intravenous access
- failure of anesthesia provider to complete training on experimental device
Plano de estudo
Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Prevenção
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Solteiro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
---|---|
Sem intervenção: Control
Control arm using standard of care operating room procedures and equipment
|
|
Experimental: Problem Solving Innovations (PSI) Experimental
Implementation of the passive bundle including HubScrub and DocIt
|
Implementation of passive bundle which includes HubScrub and DocIt device into the operating room environment.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
Presence of Bacterial IV Stopcock Lumen Contamination
Prazo: 48 hours
|
The presence of bacteria in the stopcock lumen was assessed by analyzing swab cultures of the lumens.
Each swab potentially containing bacteria from any of the 3 lumens of the stopcock sets were analyzed
|
48 hours
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
Presence of Positive Bacterial Culture in IV Stopcock Due to Effluent Contamination
Prazo: Until positive, up to 5 days
|
Open lumen ports were removed from the patient; sent directly to the anesthesiology microbiology laboratory; connected by the same clinical laboratory scientist to sterile catheters using sterile, aseptic technique; and injected directly into a BacT/Alert 3D system (bioMérieux Inc., Durham, NC) with 2 mL of sterile saline per port.
BacT/Alert is a blood culture system that automatically monitors bacterial growth using colorimetry; a sensor inserted at the bottom of the bottle changes color on detecting the carbon dioxide produced by the growth of the bacteria.
Catheters were then removed, and the bottles were directly incubated in the BacT/Alert system for 5 days or until positive.
Once positive, the liquid in the bottle was examined to identify the organism.
|
Until positive, up to 5 days
|
Colaboradores e Investigadores
É aqui que você encontrará pessoas e organizações envolvidas com este estudo.
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Bryan S Brindeiro, MD, Dartmouth-Hitchcock Medical Center
- Diretor de estudo: Randy W Loftus, MD, Dartmouth-Hitchcock Medical Center
Publicações e links úteis
A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.
Publicações Gerais
- Loftus RW, Koff MD, Burchman CC, Schwartzman JD, Thorum V, Read ME, Wood TA, Beach ML. Transmission of pathogenic bacterial organisms in the anesthesia work area. Anesthesiology. 2008 Sep;109(3):399-407. doi: 10.1097/ALN.0b013e318182c855.
- Koff MD, Loftus RW, Burchman CC, Schwartzman JD, Read ME, Henry ES, Beach ML. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device. Anesthesiology. 2009 May;110(5):978-85. doi: 10.1097/ALN.0b013e3181a06ec3.
- Loftus RW, Muffly MK, Brown JR, Beach ML, Koff MD, Corwin HL, Surgenor SD, Kirkland KB, Yeager MP. Hand contamination of anesthesia providers is an important risk factor for intraoperative bacterial transmission. Anesth Analg. 2011 Jan;112(1):98-105. doi: 10.1213/ANE.0b013e3181e7ce18. Epub 2010 Aug 4.
- Loftus RW, Brindeiro BS, Kispert DP, Patel HM, Koff MD, Jensen JT, Dodds TM, Yeager MP, Ruoff KL, Gallagher JD, Beach ML, Brown JR. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a passive catheter care system. Anesth Analg. 2012 Dec;115(6):1315-23. doi: 10.1213/ANE.0b013e31826d2aa4. Epub 2012 Nov 9.
Datas de registro do estudo
Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.
Datas Principais do Estudo
Início do estudo
1 de agosto de 2011
Conclusão Primária (Real)
1 de novembro de 2011
Conclusão do estudo (Real)
1 de novembro de 2011
Datas de inscrição no estudo
Enviado pela primeira vez
29 de agosto de 2011
Enviado pela primeira vez que atendeu aos critérios de CQ
30 de agosto de 2011
Primeira postagem (Estimativa)
31 de agosto de 2011
Atualizações de registro de estudo
Última Atualização Postada (Real)
18 de outubro de 2018
Última atualização enviada que atendeu aos critérios de controle de qualidade
20 de setembro de 2018
Última verificação
1 de agosto de 2018
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 22743
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Infecções pós-operatórias
-
Uppsala UniversityForensic Toxicology Laboratory, SwedenConcluídoConcentrações séricas | Intoxicação | Concentrações Post MortemSuécia
-
Federal University of PelotasDesconhecidoDente Não Vital | Dentadura, Parcial, Removível | Resinas Compostas | Restaurações Metal Cerâmica | Técnica Post e CoreBrasil