Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Reduction in IV Associated Contamination

20 сентября 2018 г. обновлено: Dartmouth-Hitchcock Medical Center

Reduction in Intraoperative Lumen Contamination of Standard 3-Way Open Lumen Stopcock Sets Through Use of a Novel, Passive Bundle

The purpose of this study is to investigate whether implementing a novel syringe and IV stopcock cap system impregnated with alcohol will reduce IV catheter bacterial contamination and infections in patients.

Обзор исследования

Подробное описание

Bacterial contamination of patient intravenous stopcock sets is a common intraoperative event associated with increased patient mortality, possibly via an infectious mechanism. The most common type of intravenous tubing used in operating rooms is the open lumen stopcock set which lacks a barrier between the environment and intraluminal space, and thus the intravascular space of the patient. The stopcock connector can be easily contaminated by provider hands due to improper handling of the device and/or contaminated by soiled syringe tips subsequently connected to the device. Further, the stopcock connector is often left uncapped by the provider and directly exposed to the environment. Thus, common breaches in intraoperative aseptic practice of healthcare providers can lead to bacterial contamination of the endoluminal space of the open lumen device. The primary aim of the current study is to assess the efficacy of a passive bundle designed to decrease intravenous stopcock and tubing intraluminal bacterial contamination. This passive bundle includes two novel interventions, a DOCit station and HubScrub caps. The HubScrub is designed to clean the needleless connectors and open lumen stopcock systems. The DOCit station is designed to simultaneously clean the interior and exterior of needle-less luer connectors of syringes with isopropyl alcohol while also providing a method of storage and organization of multiple syringes. The investigators hypothesize that the application of this passive bundle to the standard open lumen system commonly employed by anesthesia providers in the operating room will significantly reduce bacterial contamination of standard 3-way open lumen stopcock sets and improve patient safety.

Тип исследования

Интервенционный

Регистрация (Действительный)

594

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

18 лет и старше (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • Adult patient undergoing surgery or procedure in operating room
  • Undergoing general anesthesia

Exclusion Criteria:

  • Children (age < 18 years)
  • Lack of intravenous access
  • failure of anesthesia provider to complete training on experimental device

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Профилактика
  • Распределение: Рандомизированный
  • Интервенционная модель: Параллельное назначение
  • Маскировка: Одинокий

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Без вмешательства: Control
Control arm using standard of care operating room procedures and equipment
Экспериментальный: Problem Solving Innovations (PSI) Experimental
Implementation of the passive bundle including HubScrub and DocIt
Implementation of passive bundle which includes HubScrub and DocIt device into the operating room environment.
Другие имена:
  • PSI Medical HubScrub
  • PSI Medical DocIt

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Presence of Bacterial IV Stopcock Lumen Contamination
Временное ограничение: 48 hours
The presence of bacteria in the stopcock lumen was assessed by analyzing swab cultures of the lumens. Each swab potentially containing bacteria from any of the 3 lumens of the stopcock sets were analyzed
48 hours

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Presence of Positive Bacterial Culture in IV Stopcock Due to Effluent Contamination
Временное ограничение: Until positive, up to 5 days
Open lumen ports were removed from the patient; sent directly to the anesthesiology microbiology laboratory; connected by the same clinical laboratory scientist to sterile catheters using sterile, aseptic technique; and injected directly into a BacT/Alert 3D system (bioMérieux Inc., Durham, NC) with 2 mL of sterile saline per port. BacT/Alert is a blood culture system that automatically monitors bacterial growth using colorimetry; a sensor inserted at the bottom of the bottle changes color on detecting the carbon dioxide produced by the growth of the bacteria. Catheters were then removed, and the bottles were directly incubated in the BacT/Alert system for 5 days or until positive. Once positive, the liquid in the bottle was examined to identify the organism.
Until positive, up to 5 days

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Соавторы

Следователи

  • Главный следователь: Bryan S Brindeiro, MD, Dartmouth-Hitchcock Medical Center
  • Директор по исследованиям: Randy W Loftus, MD, Dartmouth-Hitchcock Medical Center

Публикации и полезные ссылки

Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования

1 августа 2011 г.

Первичное завершение (Действительный)

1 ноября 2011 г.

Завершение исследования (Действительный)

1 ноября 2011 г.

Даты регистрации исследования

Первый отправленный

29 августа 2011 г.

Впервые представлено, что соответствует критериям контроля качества

30 августа 2011 г.

Первый опубликованный (Оценивать)

31 августа 2011 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

18 октября 2018 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

20 сентября 2018 г.

Последняя проверка

1 августа 2018 г.

Дополнительная информация

Термины, связанные с этим исследованием

Дополнительные соответствующие термины MeSH

Другие идентификационные номера исследования

  • 22743

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .