Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Reduction of Fluoroscopy Exposure During Atrial Fibrillation Ablation (AF-FII)

7 de octubre de 2014 actualizado por: Christopher Piorkowski, Technische Universität Dresden

Atrial Fibrillation Ablation Facilitated by Fluoroscopy Image Integrated 3-dimentional Electroanatomical Mapping System

To evaluate reduction of fluoroscopy time/dosis and safety of atrial fibrillation ablation in patients with paroxysmal atrial fibrillation using fluoroscopy image integrated 3-dimentional electroanatomical mapping system, comparing to using 3-dimentional electroanatomical mapping system without fluoroscopy image integration

Descripción general del estudio

Estado

Terminado

Descripción detallada

The novel fluoroscopic image integrated 3-dimentional electroanatomical mapping system is designed for minimizing the exposure to X-ray for physician, staff and patients. This randomized single-center study is to evaluate the reduction on fluoroscopy levels (time and dosis) in catheter interventional treatment of symptomatic, antiarrhythmic refractory paroxysmal atrial fibrillation using fluoroscopic image integrated 3-dimentional electroanatomical mapping system, comparing with using 3-dimentional electroanatomical mapping system without fluoroscopic image integration. Patients with documented paroxysmal atrial fibrillation, who are going to receive a catheter interventional treatment to atrial fibrillation, will be randomized (1:1) into two groups after signing an informed consent. Group 1 (CARTOUNIVU): using fluoroscopic image integrated 3-dimentional electroanatomical mapping system. Group 2 (CARTO3): using 3-dimentional electroanatomical mapping system without fluoroscopic image integration.

The ablation strategies in both study groups are the same, including circumferential isolation of ipsilateral pulmonary veins (PV) and voltage map guided substrate modification. According to the randomization, the ablation procedure will be performed with or without fluoroscopic image integration.

The primary endpoint of this study is the evaluation of reduction on fluoroscopy levels (fluoroscopy time and dosis) during atrial fibrillation ablation procedure. Secondary endpoints include complete isolation of the pulmonary veins, completely bidirectional block of linear ablation lines, total procedure time, ablation-related complications.

Tipo de estudio

Intervencionista

Inscripción (Actual)

80

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Saxony
      • Dresden, Saxony, Alemania, 01307
        • Department of Electrophysiology, University of Dresden - Heart Center

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 75 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • documented atrial fibrillation in the 12-lead ECG or Holter ECG
  • Paroxysmal symptomatic atrial fibrillation
  • Ineffectiveness of antiarrhythmic medication ( at least 1 medication )
  • Age 18-75 years
  • left atrial diameter <60 mm ( Transesophageal Echocardiography, parasternal )
  • A signed consent form

Exclusion Criteria:

  • Reversible etiology of atrial fibrillation
  • Pregnancy
  • Women of childbearing potential without a negative pregnancy test within 48 hours prior to the ablation procedure
  • Intracardiac thrombus
  • Contraindication to anticoagulation
  • Thromboembolic event in the last 6 months
  • Previous left atrial ablation

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Prevención
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: CARTOUNIVU
Radiofrequency catheter ablation of atrial fibrillation will be performed using fluoroscopy image integrated 3-dimentional electroanatomical mapping system
Radio-frequency atrial fibrillation catheter ablation includes circumferential PV isolation and voltage-map guided substrate modification, which means low voltage zone (amplitude < o.5 mV) will also be ablated.
Comparador activo: CARTO3
Radiofrequency catheter ablation of atrial fibrillation will be performed using 3-dimentional electroanatomical mapping system without fluoroscopy image integration technique
Radio-frequency atrial fibrillation catheter ablation includes circumferential PV isolation and voltage-map guided substrate modification, which means low voltage zone (amplitude < o.5 mV) will also be ablated.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Fluoroscopy time for each step of atrial fibrillation ablation procedure
Periodo de tiempo: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
Fluoroscopy time will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.
1 day ( at the end of each step of atrial fibrillation ablation procedure)
Fluoroscopy doses for each step of atrial fibrillation ablation procedure
Periodo de tiempo: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
Fluoroscopy doses will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.
1 day ( at the end of each step of atrial fibrillation ablation procedure)

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Number of patients with adverse events as a measure of safety
Periodo de tiempo: All patients will be followed for the duration of hospital stay for acute complications, an expected average of 3 days.
Perforation, tamponed, phrenic nerve injury and oesophagus injury (patients will be screened for oesophagus injury for a month after atrial fibrillation ablation), etc.
All patients will be followed for the duration of hospital stay for acute complications, an expected average of 3 days.
Number of patients with a failure of reaching endpoints of procedure as a measure of efficacy
Periodo de tiempo: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
number of pulmonary veins/linear ablation lines has not been completely isolated/blocked at the end of the AF ablation
1 day ( at the end of each step of atrial fibrillation ablation procedure)
Total time of atrial fibrillation ablation procedure as a measure of efficacy
Periodo de tiempo: up to 24 hours
procedure time (minute)
up to 24 hours

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Colaboradores

Investigadores

  • Investigador principal: Christopher Piorkowski, M.D., Department of Electrophysiology, University of Dresden - Heart Center

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de marzo de 2014

Finalización primaria (Actual)

1 de septiembre de 2014

Finalización del estudio (Actual)

1 de septiembre de 2014

Fechas de registro del estudio

Enviado por primera vez

2 de mayo de 2014

Primero enviado que cumplió con los criterios de control de calidad

13 de mayo de 2014

Publicado por primera vez (Estimar)

14 de mayo de 2014

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

9 de octubre de 2014

Última actualización enviada que cumplió con los criterios de control de calidad

7 de octubre de 2014

Última verificación

1 de octubre de 2014

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • EK474122013
  • CARTOUNIVU (Otro número de subvención/financiamiento: Biosense Webster)

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir