- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT02137798
Reduction of Fluoroscopy Exposure During Atrial Fibrillation Ablation (AF-FII)
Atrial Fibrillation Ablation Facilitated by Fluoroscopy Image Integrated 3-dimentional Electroanatomical Mapping System
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
The novel fluoroscopic image integrated 3-dimentional electroanatomical mapping system is designed for minimizing the exposure to X-ray for physician, staff and patients. This randomized single-center study is to evaluate the reduction on fluoroscopy levels (time and dosis) in catheter interventional treatment of symptomatic, antiarrhythmic refractory paroxysmal atrial fibrillation using fluoroscopic image integrated 3-dimentional electroanatomical mapping system, comparing with using 3-dimentional electroanatomical mapping system without fluoroscopic image integration. Patients with documented paroxysmal atrial fibrillation, who are going to receive a catheter interventional treatment to atrial fibrillation, will be randomized (1:1) into two groups after signing an informed consent. Group 1 (CARTOUNIVU): using fluoroscopic image integrated 3-dimentional electroanatomical mapping system. Group 2 (CARTO3): using 3-dimentional electroanatomical mapping system without fluoroscopic image integration.
The ablation strategies in both study groups are the same, including circumferential isolation of ipsilateral pulmonary veins (PV) and voltage map guided substrate modification. According to the randomization, the ablation procedure will be performed with or without fluoroscopic image integration.
The primary endpoint of this study is the evaluation of reduction on fluoroscopy levels (fluoroscopy time and dosis) during atrial fibrillation ablation procedure. Secondary endpoints include complete isolation of the pulmonary veins, completely bidirectional block of linear ablation lines, total procedure time, ablation-related complications.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Saxony
-
Dresden, Saxony, Alemanha, 01307
- Department of Electrophysiology, University of Dresden - Heart Center
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- documented atrial fibrillation in the 12-lead ECG or Holter ECG
- Paroxysmal symptomatic atrial fibrillation
- Ineffectiveness of antiarrhythmic medication ( at least 1 medication )
- Age 18-75 years
- left atrial diameter <60 mm ( Transesophageal Echocardiography, parasternal )
- A signed consent form
Exclusion Criteria:
- Reversible etiology of atrial fibrillation
- Pregnancy
- Women of childbearing potential without a negative pregnancy test within 48 hours prior to the ablation procedure
- Intracardiac thrombus
- Contraindication to anticoagulation
- Thromboembolic event in the last 6 months
- Previous left atrial ablation
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Prevenção
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: CARTOUNIVU
Radiofrequency catheter ablation of atrial fibrillation will be performed using fluoroscopy image integrated 3-dimentional electroanatomical mapping system
|
Radio-frequency atrial fibrillation catheter ablation includes circumferential PV isolation and voltage-map guided substrate modification, which means low voltage zone (amplitude < o.5 mV) will also be ablated.
|
|
Comparador Ativo: CARTO3
Radiofrequency catheter ablation of atrial fibrillation will be performed using 3-dimentional electroanatomical mapping system without fluoroscopy image integration technique
|
Radio-frequency atrial fibrillation catheter ablation includes circumferential PV isolation and voltage-map guided substrate modification, which means low voltage zone (amplitude < o.5 mV) will also be ablated.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Fluoroscopy time for each step of atrial fibrillation ablation procedure
Prazo: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
|
Fluoroscopy time will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.
|
1 day ( at the end of each step of atrial fibrillation ablation procedure)
|
|
Fluoroscopy doses for each step of atrial fibrillation ablation procedure
Prazo: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
|
Fluoroscopy doses will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.
|
1 day ( at the end of each step of atrial fibrillation ablation procedure)
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Number of patients with adverse events as a measure of safety
Prazo: All patients will be followed for the duration of hospital stay for acute complications, an expected average of 3 days.
|
Perforation, tamponed, phrenic nerve injury and oesophagus injury (patients will be screened for oesophagus injury for a month after atrial fibrillation ablation), etc.
|
All patients will be followed for the duration of hospital stay for acute complications, an expected average of 3 days.
|
|
Number of patients with a failure of reaching endpoints of procedure as a measure of efficacy
Prazo: 1 day ( at the end of each step of atrial fibrillation ablation procedure)
|
number of pulmonary veins/linear ablation lines has not been completely isolated/blocked at the end of the AF ablation
|
1 day ( at the end of each step of atrial fibrillation ablation procedure)
|
|
Total time of atrial fibrillation ablation procedure as a measure of efficacy
Prazo: up to 24 hours
|
procedure time (minute)
|
up to 24 hours
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Christopher Piorkowski, M.D., Department of Electrophysiology, University of Dresden - Heart Center
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- EK474122013
- CARTOUNIVU (Número de outro subsídio/financiamento: Biosense Webster)
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .