Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Detection of Colorectal Adenoma by Optical Enhancement Technology vs. High-Definition Colonoscopy

11 de octubre de 2016 actualizado por: Yanqing Li

Detection of Colorectal Adenoma by Optical Enhancement Technology vs. High-Definition Colonoscopy: A Randomized Trial

Optical Enhancement Technology might be superior to the conventional HD-WL in detecting colorectal adenomas

Descripción general del estudio

Descripción detallada

Colorectal cancer is the third most common cancer in the world.Colonoscopy is the gold standard screening test for colorectal cancer.There are also emerging data to support that screening by colonoscopy reduces both the incidence and mortality of colorectal cancer.However,Colonoscopy could still miss colorectal adenomas and even cancer.The miss rate for colonic adenomas was reported to be ranging from 15 to 32% in tandem colonoscopy studies.The reasons for the miss rate may be technical(insufficient during excessively fast instrument withdrawal),but may also be the imaging method.Smaller lesions ,particularly flat ones ,may be missed as a result of their subtle appearance and limited contrast in relation to the surrounding mucosa.

Some image-enhanced modules were developed with an aim to improve colorectal polyp or adenoma detection.The widely available modules is the narrow band imaging(NBI).However,most studies failed to demonstrate any superiority of NBI system over white light colonoscopy in detecting colonic polyps.NBI provides dimmer images of the colonic mucosa ,which may limit its performance on polyp and adenoma detection.

Like NBI,OE technology is image-enhanced module,providing a more intense look at the vascular pattern morphology.Besides,OE technology provides an much brighter image compared to NBI.This may possibly increase polyp detection by enhancing visibility of the colonic mucosa with brighter image.The current study aims to tested whether OE technology would improve adenoma detection when compared with high-definition colonoscopy.

Tipo de estudio

Intervencionista

Inscripción (Anticipado)

400

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Shandong
      • Jinan, Shandong, Porcelana, 250012
        • Department of Gastroenterology, Qilu Hospital, Shandong University

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

14 años a 76 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Patients were selected if they presented for diagnostic colonoscopy for a variety of indications(eg positive fecal occult blood test, abdominal pain, diarrhoea,post-polypectomy surveillance).

Exclusion Criteria:

  • Patients with prior resection of the proximal colon, advanced colonic cancer, inflammatory bowel disease, or polyposis syndrome.
  • The cecum could not be intubated.
  • Inadequate bowel preparation (Aronchick Bowel Preparation Scale score poor or inadequate).
  • Biopsies were not available.
  • Unable to provide informed consent.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Prevención
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Único

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Group A
white light was used for both insertion and withdrawal of the colonoscope
Experimental: Group B
Insertion to cecum was performed under white light and once the cecum was reached,the OE mode was swithed on during withdrawal of endoscope for complete colonic examination

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Periodo de tiempo
adenoma detection rate
Periodo de tiempo: 6 months
6 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Director de estudio: Yanqing Li, MD, PhD, Department of Gastroenterology, Qilu Hospital, Shandong University, Jinan, Shandong Province, China

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de septiembre de 2016

Finalización primaria (Anticipado)

1 de febrero de 2017

Finalización del estudio (Anticipado)

1 de marzo de 2017

Fechas de registro del estudio

Enviado por primera vez

2 de agosto de 2016

Primero enviado que cumplió con los criterios de control de calidad

9 de agosto de 2016

Publicado por primera vez (Estimar)

12 de agosto de 2016

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

12 de octubre de 2016

Última actualización enviada que cumplió con los criterios de control de calidad

11 de octubre de 2016

Última verificación

1 de agosto de 2016

Más información

Términos relacionados con este estudio

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir