Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Impact of Atrioventricular Delay Optimization on Ventricular Function in Conduction System Pacing (OPTI-CSP)

4 de junio de 2026 actualizado por: Bilal Mete Ülker, Bursa Yuksek Ihtisas Training and Research Hospital

The Effect Of Atrioventricular Delay Optimization On Ventricular Functions In Patients Undergoing Conduction System Pacing

Conduction system pacing has emerged as a physiological pacing strategy that preserves ventricular electrical activation and minimizes pacing-induced dyssynchrony. However, the optimal atrioventricular delay setting in patients undergoing conduction system pacing remains uncertain.

This study aims to evaluate the effects of individualized echocardiography-guided atrioventricular delay optimization on ventricular function and hemodynamic performance in patients with conduction system pacing. Echocardiographic parameters including global longitudinal strain, left ventricular ejection fraction, left ventricular outflow tract velocity-time integral, cardiac output, and diastolic function indices will be assessed before and after atrioventricular delay optimization.

The study will investigate whether optimization of atrioventricular timing provides additional mechanical and hemodynamic benefits beyond physiological ventricular activation achieved by conduction system pacing alone.

Descripción general del estudio

Descripción detallada

Conduction system pacing (CSP), including His bundle pacing and left bundle branch area pacing, has emerged as a physiological pacing strategy capable of preserving ventricular electrical activation and reducing pacing-induced dyssynchrony. Compared with conventional right ventricular pacing, CSP has been associated with improved electrical synchrony, ventricular function, and clinical outcomes.

Despite restoration of physiological ventricular activation, optimal atrioventricular (AV) coupling remains essential for maximizing ventricular filling, stroke volume, and overall cardiac performance. Inadequate AV timing may impair diastolic filling, reduce atrial contribution to ventricular preload, and limit the hemodynamic benefits achieved by physiological pacing. While AV delay optimization has been extensively investigated in cardiac resynchronization therapy, data regarding its role in patients undergoing CSP remain limited.

The present study evaluates the impact of individualized echocardiography-guided AV delay optimization on ventricular mechanical performance and hemodynamic parameters in patients with CSP implanted for atrioventricular block. Comprehensive transthoracic echocardiographic assessment will be performed before and after AV delay optimization. Measurements include left ventricular ejection fraction, global longitudinal strain, left ventricular outflow tract velocity-time integral, cardiac output, chamber dimensions, pulmonary artery systolic pressure, and diastolic function parameters.

The primary objective is to determine the effect of AV delay optimization on global longitudinal strain. Secondary objectives include assessment of changes in left ventricular systolic function, hemodynamic performance, and diastolic parameters. The study aims to provide additional evidence regarding the importance of individualized AV programming in patients undergoing conduction system pacing.

Tipo de estudio

Intervencionista

Inscripción (Actual)

39

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Yıldırım
      • Bursa, Yıldırım, Turquía (Türkiye)
        • University of Health Sciences Bursa Yuksek Ihtisas Training and Research Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  • Age between 18 and 80 years
  • Permanent conduction system pacing implantation for atrioventricular block
  • At least 1 month elapsed since device implantation
  • Sinus rhythm at the time of enrollment
  • Left ventricular ejection fraction >40%
  • Adequate echocardiographic image quality for comprehensive assessment
  • Ability and willingness to provide informed consent

Exclusion Criteria:

  • Permanent or persistent atrial fibrillation
  • Significant valvular heart disease
  • Active malignancy
  • Severe systemic illness with limited life expectancy
  • Sinus node dysfunction requiring alternative pacing strategies
  • Inadequate echocardiographic image quality
  • Inability to comply with study procedures
  • Refusal to participate in the study

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Echocardiography-Guided AV Delay Optimization
Participants with conduction system pacing undergo individualized echocardiography-guided atrioventricular delay optimization. Echocardiographic and hemodynamic parameters are assessed before and after optimization.
Atrioventricular delay settings are individually optimized using echocardiographic assessment of transmitral inflow and ventricular filling patterns. Device programming is adjusted to achieve optimal atrioventricular coupling and ventricular performance.
Otros nombres:
  • AV Delay Optimization

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Global Longitudinal Strain (GLS)
Periodo de tiempo: Immediately before and immediately after atrioventricular delay optimization.
Assessment of left ventricular global longitudinal strain using two-dimensional speckle tracking echocardiography before and after atrioventricular delay optimization.
Immediately before and immediately after atrioventricular delay optimization.

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Left Ventricular Outflow Tract Velocity-Time Integral (LVOT VTI)
Periodo de tiempo: Immediately before and immediately after atrioventricular delay optimization.
Assessment of forward stroke volume using pulsed-wave Doppler measurements at the left ventricular outflow tract.
Immediately before and immediately after atrioventricular delay optimization.
Left Ventricular Ejection Fraction (LVEF)
Periodo de tiempo: Immediately before and immediately after atrioventricular delay optimization.
Assessment of left ventricular systolic function using the biplane Simpson method.
Immediately before and immediately after atrioventricular delay optimization.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Silla de estudio: Ahmet Tütüncü, Bursa Yuksek Ihtisas Training and Research Hospital

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

  • Glikson et al. ESC Clinical Consensus Statement on Conduction System Pacing Glikson M, Vijayaraman P, Ellenbogen KA, et al. European Society of Cardiology (ESC) clinical consensus statement on indications for conduction system pacing. Europace. 2025;27(4):euaf050. Coluccia et al. Optimization of the Atrioventricular Delay in Conduction System Pacing Coluccia G, Padeletti L, Della Bella P, et al. Optimization of the atrioventricular delay in conduction system pacing. J Cardiovasc Electrophysiol. 2023;34(6):1441-1451. Pujol-López et al. LEVEL-AT Trial Secondary Findings Pujol-López M, et al. Longitudinal comparison of dyssynchrony correction and strain improvement by conduction system pacing: LEVEL-AT trial secondary findings. Eur Heart J Cardiovasc Imaging. 2024;25(10):1394-1404. Hua et al. Comparison of Left Bundle Branch and His Bundle Pacing Hua W, Fan X, Niu H, et al. Comparison of left bundle branch and His bundle pacing in bradycardia patients. JACC Clin Electrophysiol. 2020;6(10):1291-1299. Sweeney et al. Adverse Effect of Ventricular Pacing Sweeney MO, Hellkamp AS, Ellenbogen KA, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration. Circulation. 2003;107(23):2932-2937.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

6 de octubre de 2025

Finalización primaria (Actual)

17 de febrero de 2026

Finalización del estudio (Actual)

17 de febrero de 2026

Fechas de registro del estudio

Enviado por primera vez

29 de mayo de 2026

Primero enviado que cumplió con los criterios de control de calidad

29 de mayo de 2026

Publicado por primera vez (Actual)

3 de junio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

8 de junio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

4 de junio de 2026

Última verificación

1 de junio de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir