Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Impact of Atrioventricular Delay Optimization on Ventricular Function in Conduction System Pacing (OPTI-CSP)

4 giugno 2026 aggiornato da: Bilal Mete Ülker, Bursa Yuksek Ihtisas Training and Research Hospital

The Effect Of Atrioventricular Delay Optimization On Ventricular Functions In Patients Undergoing Conduction System Pacing

Conduction system pacing has emerged as a physiological pacing strategy that preserves ventricular electrical activation and minimizes pacing-induced dyssynchrony. However, the optimal atrioventricular delay setting in patients undergoing conduction system pacing remains uncertain.

This study aims to evaluate the effects of individualized echocardiography-guided atrioventricular delay optimization on ventricular function and hemodynamic performance in patients with conduction system pacing. Echocardiographic parameters including global longitudinal strain, left ventricular ejection fraction, left ventricular outflow tract velocity-time integral, cardiac output, and diastolic function indices will be assessed before and after atrioventricular delay optimization.

The study will investigate whether optimization of atrioventricular timing provides additional mechanical and hemodynamic benefits beyond physiological ventricular activation achieved by conduction system pacing alone.

Panoramica dello studio

Descrizione dettagliata

Conduction system pacing (CSP), including His bundle pacing and left bundle branch area pacing, has emerged as a physiological pacing strategy capable of preserving ventricular electrical activation and reducing pacing-induced dyssynchrony. Compared with conventional right ventricular pacing, CSP has been associated with improved electrical synchrony, ventricular function, and clinical outcomes.

Despite restoration of physiological ventricular activation, optimal atrioventricular (AV) coupling remains essential for maximizing ventricular filling, stroke volume, and overall cardiac performance. Inadequate AV timing may impair diastolic filling, reduce atrial contribution to ventricular preload, and limit the hemodynamic benefits achieved by physiological pacing. While AV delay optimization has been extensively investigated in cardiac resynchronization therapy, data regarding its role in patients undergoing CSP remain limited.

The present study evaluates the impact of individualized echocardiography-guided AV delay optimization on ventricular mechanical performance and hemodynamic parameters in patients with CSP implanted for atrioventricular block. Comprehensive transthoracic echocardiographic assessment will be performed before and after AV delay optimization. Measurements include left ventricular ejection fraction, global longitudinal strain, left ventricular outflow tract velocity-time integral, cardiac output, chamber dimensions, pulmonary artery systolic pressure, and diastolic function parameters.

The primary objective is to determine the effect of AV delay optimization on global longitudinal strain. Secondary objectives include assessment of changes in left ventricular systolic function, hemodynamic performance, and diastolic parameters. The study aims to provide additional evidence regarding the importance of individualized AV programming in patients undergoing conduction system pacing.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

39

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Yıldırım
      • Bursa, Yıldırım, Turchia (Türkiye)
        • University of Health Sciences Bursa Yuksek Ihtisas Training and Research Hospital

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Descrizione

Inclusion Criteria:

  • Age between 18 and 80 years
  • Permanent conduction system pacing implantation for atrioventricular block
  • At least 1 month elapsed since device implantation
  • Sinus rhythm at the time of enrollment
  • Left ventricular ejection fraction >40%
  • Adequate echocardiographic image quality for comprehensive assessment
  • Ability and willingness to provide informed consent

Exclusion Criteria:

  • Permanent or persistent atrial fibrillation
  • Significant valvular heart disease
  • Active malignancy
  • Severe systemic illness with limited life expectancy
  • Sinus node dysfunction requiring alternative pacing strategies
  • Inadequate echocardiographic image quality
  • Inability to comply with study procedures
  • Refusal to participate in the study

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Echocardiography-Guided AV Delay Optimization
Participants with conduction system pacing undergo individualized echocardiography-guided atrioventricular delay optimization. Echocardiographic and hemodynamic parameters are assessed before and after optimization.
Atrioventricular delay settings are individually optimized using echocardiographic assessment of transmitral inflow and ventricular filling patterns. Device programming is adjusted to achieve optimal atrioventricular coupling and ventricular performance.
Altri nomi:
  • AV Delay Optimization

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Global Longitudinal Strain (GLS)
Lasso di tempo: Immediately before and immediately after atrioventricular delay optimization.
Assessment of left ventricular global longitudinal strain using two-dimensional speckle tracking echocardiography before and after atrioventricular delay optimization.
Immediately before and immediately after atrioventricular delay optimization.

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Left Ventricular Outflow Tract Velocity-Time Integral (LVOT VTI)
Lasso di tempo: Immediately before and immediately after atrioventricular delay optimization.
Assessment of forward stroke volume using pulsed-wave Doppler measurements at the left ventricular outflow tract.
Immediately before and immediately after atrioventricular delay optimization.
Left Ventricular Ejection Fraction (LVEF)
Lasso di tempo: Immediately before and immediately after atrioventricular delay optimization.
Assessment of left ventricular systolic function using the biplane Simpson method.
Immediately before and immediately after atrioventricular delay optimization.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Cattedra di studio: Ahmet Tütüncü, Bursa Yuksek Ihtisas Training and Research Hospital

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

  • Glikson et al. ESC Clinical Consensus Statement on Conduction System Pacing Glikson M, Vijayaraman P, Ellenbogen KA, et al. European Society of Cardiology (ESC) clinical consensus statement on indications for conduction system pacing. Europace. 2025;27(4):euaf050. Coluccia et al. Optimization of the Atrioventricular Delay in Conduction System Pacing Coluccia G, Padeletti L, Della Bella P, et al. Optimization of the atrioventricular delay in conduction system pacing. J Cardiovasc Electrophysiol. 2023;34(6):1441-1451. Pujol-López et al. LEVEL-AT Trial Secondary Findings Pujol-López M, et al. Longitudinal comparison of dyssynchrony correction and strain improvement by conduction system pacing: LEVEL-AT trial secondary findings. Eur Heart J Cardiovasc Imaging. 2024;25(10):1394-1404. Hua et al. Comparison of Left Bundle Branch and His Bundle Pacing Hua W, Fan X, Niu H, et al. Comparison of left bundle branch and His bundle pacing in bradycardia patients. JACC Clin Electrophysiol. 2020;6(10):1291-1299. Sweeney et al. Adverse Effect of Ventricular Pacing Sweeney MO, Hellkamp AS, Ellenbogen KA, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration. Circulation. 2003;107(23):2932-2937.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

6 ottobre 2025

Completamento primario (Effettivo)

17 febbraio 2026

Completamento dello studio (Effettivo)

17 febbraio 2026

Date di iscrizione allo studio

Primo inviato

29 maggio 2026

Primo inviato che soddisfa i criteri di controllo qualità

29 maggio 2026

Primo Inserito (Effettivo)

3 giugno 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

8 giugno 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

4 giugno 2026

Ultimo verificato

1 giugno 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Blocco atrioventricolare

Sottoscrivi