Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Noninvasive Ventilation Versus High-Flow Nasal Cannula After Extubation in High-Risk ICU Patients (NIV-HFNC)

9 de junio de 2026 actualizado por: Koot Ahmad, Benha University

Comparative Study Between Noninvasive Ventilation and High Flow Nasal Cannula in Patients With High Risk of Extubation Failure

Extubation failure is associated with increased morbidity and mortality in critically ill patients. High-risk patients may benefit from preventive respiratory support after extubation. This randomized controlled trial compared noninvasive ventilation (NIV) with high-flow nasal cannula (HFNC) in adult intensive care unit (ICU) patients at high risk of extubation failure. The study evaluated reintubation rates, time to reintubation, physiological parameters, complications, and clinical outcomes following planned extubation. The aim was to determine the optimal post-extubation respiratory support strategy for reducing extubation failure in high-risk ICU patients.

Descripción general del estudio

Estado

Terminado

Intervención / Tratamiento

Tipo de estudio

Intervencionista

Inscripción (Actual)

102

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Qalyubia Governorate
      • Banhā, Qalyubia Governorate, Egipto, 13511
        • Benha University Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

inclusion criteria

  1. Age ≥18 years.
  2. Received invasive mechanical ventilation for at least 24 hours.
  3. Considered ready for planned extubation after successful completion of a spontaneous breathing trial.
  4. High risk of extubation failure, defined by the presence of at least four of the following risk factors:

Age >65 years. APACHE II score >12 on the day of extubation. Body mass index >30 kg/m². Inadequate secretion management. Difficult or prolonged weaning. Two or more comorbidities. Acute heart failure requiring mechanical ventilation. Moderate-to-severe chronic obstructive pulmonary disease. Airway patency problems. Prolonged mechanical ventilation. Hypercapnia at the end of the spontaneous breathing trial.

Exclusion Criteria:

  1. Age <18 years.
  2. Presence of a tracheostomy.
  3. Accidental extubation.
  4. Self-extubation.
  5. Contraindication to noninvasive ventilation.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: NIV
Patients received noninvasive ventilation immediately after planned extubation according to the study protocol.
NIV was initiated immediately after extubation using bilevel positive airway pressure delivered via a properly fitted face mask with active humidification using a Dräger Savina 300 ventilator (Drägerwerk AG & Co. KGaA, Lübeck, Germany). Ventilator settings were adjusted to achieve a respiratory rate <26 breaths/min, tidal volume of 6-8 mL/kg predicted body weight, and adequate oxygenation (SpO₂ ≥92%, pH ≥7.35). Sedation was not permitted.
Comparador activo: HFNC
Patients received high-flow nasal cannula oxygen therapy immediately after planned extubation according to the study protocol.

HFNC was applied immediately after extubation using a heated humidified high-flow nasal cannula system (BioVent A-Series, Model: BioHF BB60101; BIO-AOI, Cairo, Egypt). Flow was initially set at 10 L/min and titrated up to 60 L/min according to patient tolerance. Gas temperature was maintained at 37°C.

In both groups, FiO₂ was adjusted to maintain SpO₂ ≥92%. After 48 hours, respiratory support was discontinued and conventional oxygen therapy was provided if required. Rescue NIV was not allowed in the HFNC group. All patients received standardized care.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Reintubation Rate
Periodo de tiempo: 7 days
Proportion of patients requiring reintubation following planned extubation.
7 days

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Time to Reintubation
Periodo de tiempo: 7 days
Time elapsed from extubation to reintubation among patients requiring reintubation.
7 days

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

30 de julio de 2025

Finalización primaria (Actual)

30 de abril de 2026

Finalización del estudio (Actual)

15 de mayo de 2026

Fechas de registro del estudio

Enviado por primera vez

2 de junio de 2026

Primero enviado que cumplió con los criterios de control de calidad

2 de junio de 2026

Publicado por primera vez (Actual)

5 de junio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

11 de junio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

9 de junio de 2026

Última verificación

1 de junio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • RC.16.7.2025

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir