- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT07630766
Noninvasive Ventilation Versus High-Flow Nasal Cannula After Extubation in High-Risk ICU Patients (NIV-HFNC)
Comparative Study Between Noninvasive Ventilation and High Flow Nasal Cannula in Patients With High Risk of Extubation Failure
Обзор исследования
Статус
Условия
Вмешательство/лечение
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Qalyubia Governorate
-
Banhā, Qalyubia Governorate, Египет, 13511
- Benha University Hospital
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Описание
inclusion criteria
- Age ≥18 years.
- Received invasive mechanical ventilation for at least 24 hours.
- Considered ready for planned extubation after successful completion of a spontaneous breathing trial.
- High risk of extubation failure, defined by the presence of at least four of the following risk factors:
Age >65 years. APACHE II score >12 on the day of extubation. Body mass index >30 kg/m². Inadequate secretion management. Difficult or prolonged weaning. Two or more comorbidities. Acute heart failure requiring mechanical ventilation. Moderate-to-severe chronic obstructive pulmonary disease. Airway patency problems. Prolonged mechanical ventilation. Hypercapnia at the end of the spontaneous breathing trial.
Exclusion Criteria:
- Age <18 years.
- Presence of a tracheostomy.
- Accidental extubation.
- Self-extubation.
- Contraindication to noninvasive ventilation.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Двойной
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: NIV
Patients received noninvasive ventilation immediately after planned extubation according to the study protocol.
|
NIV was initiated immediately after extubation using bilevel positive airway pressure delivered via a properly fitted face mask with active humidification using a Dräger Savina 300 ventilator (Drägerwerk AG & Co. KGaA, Lübeck, Germany).
Ventilator settings were adjusted to achieve a respiratory rate <26 breaths/min, tidal volume of 6-8 mL/kg predicted body weight, and adequate oxygenation (SpO₂ ≥92%, pH ≥7.35).
Sedation was not permitted.
|
|
Активный компаратор: HFNC
Patients received high-flow nasal cannula oxygen therapy immediately after planned extubation according to the study protocol.
|
HFNC was applied immediately after extubation using a heated humidified high-flow nasal cannula system (BioVent A-Series, Model: BioHF BB60101; BIO-AOI, Cairo, Egypt). Flow was initially set at 10 L/min and titrated up to 60 L/min according to patient tolerance. Gas temperature was maintained at 37°C. In both groups, FiO₂ was adjusted to maintain SpO₂ ≥92%. After 48 hours, respiratory support was discontinued and conventional oxygen therapy was provided if required. Rescue NIV was not allowed in the HFNC group. All patients received standardized care. |
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Reintubation Rate
Временное ограничение: 7 days
|
Proportion of patients requiring reintubation following planned extubation.
|
7 days
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Time to Reintubation
Временное ограничение: 7 days
|
Time elapsed from extubation to reintubation among patients requiring reintubation.
|
7 days
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Другие идентификационные номера исследования
- RC.16.7.2025
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .