Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Non-Invasive Characterization in Cardiac Sarcoidosis

3 juillet 2018 mis à jour par: Venkatesh L. Murthy, M.D., Ph.D., University of Michigan
In a study of Cardiac sarcoidosis, a serious heart condition, a radiotracer is being used to examine inflammation.

Aperçu de l'étude

Statut

Résilié

Les conditions

Intervention / Traitement

Description détaillée

Cardiac sarcoidosis is a serious medical condition which affects the heart. The purpose of this study is to characterize the relationship between the FDG PET findings and other markers of inflammation including using a new targeted PET radiotracer, 11C-PBR28, and analysis of blood specimens.

Type d'étude

Interventionnel

Inscription (Réel)

3

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Michigan
      • Ann Arbor, Michigan, États-Unis, 48109
        • University of Michigan Hospital

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  1. 18 years of age or older
  2. must have undergone a cardiac positron emission tomography (PET) scan using 18F-fluorodeoxyglucose (FDG) for clinical reasons (i.e. referred by your doctor) within the preceding 30 days which showed evidence of active inflammation in your heart.

Exclusion Criteria:

  1. If you have two copies of a genetic variation called rs6971 which will prevent this tracer from generating high-quality images you may not participate. If you consent, a blood sample will be drawn to check whether you have this genetic variation.
  2. Pregnancy or breastfeeding. If you are female and still experience menstrual periods, you must be willing to use contraception until your participation in the study is complete.
  3. Allergy or intolerance to contrast dye containing gadolinium
  4. Claustrophobia which would prevent you from completing an approximately one hour MRI scan
  5. Inability to lie flat with your arms by your head
  6. Abnormal kidney function (estimated GFR(glomerular filtration rate) <60 ml/min/1.73 m2)
  7. Implanted pacemaker, defibrillator or other medical devices which are not safe for 3 Tesla MRI
  8. Metal in the eyes or shrapnel in the body
  9. If you are clinically unstable you may not participate in this study. For example, if you have potentially life threatening abnormal heart rhythms which are not controlled by medication or other treatments, you cannot participate. Also, if you need medications to increase your blood pressure or cardiac function due to weak heart muscle, you cannot participate.

    -

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Science basique
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: 11C-PBR PET

Subjects will have a blood sample drawn to evaluate the presence of a specific genetic variation which would prevent the new type of imaging test we are evaluating from working and we will test the inflammatory cells in the blood for the same purpose.

All participants who proceed will have to return on at least one additional day to undergo a positron emission tomography (PET) scan similar to the scan your doctor ordered. we will use 11C-PBR28 as the radiotracer. This study will evaluate whether 11C-PBR28 can show areas of inflammation due to cardiac sarcoidosis. On either the same day or a different day, you will also undergo a cardiac MRI.

Subjects will have a positron emission tomography (PET) CT scan using 11C-PBR28 as a radiotracer. This study will evaluate inflammation due to cardiac sarcoidosis. The CT scan will improve the images. The total scan time will be about 30 minutes. There will also be some time required for prep, such as inserting an intravenous (IV) catheter in an arm or forearm. Including prep time, the scan will take approximately two hours.

Subjects will also undergo a cardiac MRI. Cardiac MRI uses strong magnetic fields to make pictures of the heart. We will use gadolinium containing contrast material, given through an intravenous (IV) catheter to highlight areas of scar in your heart which may be due to cardiac sarcoidosis. This scan will take about 60 minutes.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Ratio of 11C-PBR28 in the Myocardium
Délai: 1 hour scan
The primary outcome of this study will be the ratio of 11C-PBR28 PET activity in myocardial regions with inflammation indicated by FDG PET and/or edema indicated by increased T2 signal with cardiac MRI compared to the 11C-PBR28 PET activity in myocardial segments which appear normal on FDG PET and cardiac MRI. The primary outcome is thus the intensity of uptake in abnormal regions as a percentage of the intensity of uptake in normal segments.
1 hour scan

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
The Ratio of 11C-PBR28 PET Activity in Cardiac Regions With Fibrosis
Délai: 1 hour scan

As a secondary outcome of this study we will evaluate the ratio of 11C-PBR28 PET activity in regions with fibrosis indicated by decreased myocardial perfusion on 82Rb PET and/or late gadolinium enhancement on cardiac MRI without imaging signs of active inflammation compared to 11C-PBR28 PET activity in myocardial segments which appear normal on 82Rb PET, FDG PET and cardiac MRI. This outcome will thus be expressed by 11C-PBR28 PET uptake in fibrotic regions as a percentage of uptake in normal segments

We will also evaluate the concordance between extracardiac activity seen in 11C-PBR28 and FDG PET, and when available, histopathology of contemporaneous biopsy specimens.

1 hour scan

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Venkatesh L. Murthy, M.D., University of Michigan

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

4 avril 2014

Achèvement primaire (Réel)

7 juillet 2015

Achèvement de l'étude (Réel)

7 juillet 2015

Dates d'inscription aux études

Première soumission

16 décembre 2013

Première soumission répondant aux critères de contrôle qualité

19 décembre 2013

Première publication (Estimation)

20 décembre 2013

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

1 août 2018

Dernière mise à jour soumise répondant aux critères de contrôle qualité

3 juillet 2018

Dernière vérification

1 juillet 2018

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • HUM00079881

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Oui

produit fabriqué et exporté des États-Unis.

Oui

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur 11C-PBR PET

3
S'abonner