Évaluation de la marche via une application téléphonique
Validité et fiabilité d'une application smartphone pour l'évaluation de la marche
The evaluation of human gait is a crucial component of the clinical assessment and decision-making process. The gold standard in gait analysis is computerized gait analysis, which allows for three-dimensional digital data acquisition through computers (3D Computerized Gait Analysis). However, this technology is not readily accessible in routine analyses, as it proves to be a time-consuming and expensive endeavor in terms of infrastructure and human resources. The utilization of smartphones in clinical applications is on the rise, facilitated by the increasing accessibility of low-cost or free "applications," thereby addressing the limitations associated with traditional gait analysis methods. The Gait-Analyzer application is among the mentioned applications. However, in the literature, no evidence has been found regarding the validity and reliability of Gait-Analyzer application compared to the gold standard 3D computerized gait analysis systems within the context of gait analyses.
The aim of this study is to comparatively examine the effectiveness of the Gait-Analyzer smartphone application with established 3D Computerized Gait Analysis systems, which have proven validity and reliability in gait analyses. Through this research, the study intends to elucidate the validity and reliability of spatiotemporal parameters of walking within the Gait-Analyzer smartphone application.
Aperçu de l'étude
Description détaillée
Voluntary healthy participants will be included in the study. Signed voluntary consent will be obtained from participants. Participants will be divided into two groups. 3D Computerized Gait Analysis will be applied to one group first, and Gait-Analyzer smarthphone application will be applied to the other group first.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
-
Istanbul, Turquie (Türkiye), 34752
- Acibadem Mehmet Ali Aydinlar University
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
Volunteers willing to participate in the study and who meet the inclusion criteria of being healthy
La description
Inclusion Criteria:
- Age between 18 and 26 years.
- Body Mass Index (BMI) within normal limits (18.5-24.9 kg/m2)
Exclusion Criteria:
- Presence of lower extremity rotational problems (such as high femoral anteversion, internal tibial torsion, metatarsus adductus).
- History of Botulinum Toxin Type A (BoNT-A) application or surgery within the last 6 months.
- History of lower extremity injury within the last 6 months.
- Leg length discrepancy.
- Presence of third-degree pes planus.
- Any neurological, rheumatic, musculoskeletal, metabolic, or connective tissue diseases.
- History of pain, deformity, or surgery related to the vertebral column and upper extremities.
- Presence of cognitive, mental, and/or severe psychiatric disorders
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: CASE_ONLY
- Perspectives temporelles: PROSPECTIVE
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
3D Computerized Gait Analysis
The gait analysis will be conducted through 3D computerized gait analysis. |
It will be carried out on a 10-meter flat surface, with the participant walking at normal walking speed. |
|
Gait-Analyzer
The gait analysis will be performed using a smartphone application called Gait-Analyzer. |
It will be carried out on a 10-meter flat surface, with the participant walking at normal walking speed. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Three-Dimensional Computerized Gait Analysis
Délai: change from baseline at first week
|
Reflective markers are placed on specific anatomical points to record varying joint angles throughout the walking cycle. Patients walk a distance of 9-10 meters, capturing records of their walking patterns and speed in everyday life, either barefoot or using assistive walking devices. |
change from baseline at first week
|
|
Gait-Analyzer
Délai: change from baseline at first week
|
Gait-Analyzer is a mobile application for smartphones capable of real-time analysis of walking parameters. Using a smartphone with an Android processor and the "Gait Analyzer" application, directly attached to the participants' lumbar spine (nearest to L5) with a waist belt, participants will be instructed to complete 6 laps (12 forward and backward walks) on a 10-meter walking path. |
change from baseline at first week
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Ayşenur Erekdağ, MSc, Bezmialem Vakif University
Publications et liens utiles
Publications générales
- Stuberg WA, Colerick VL, Blanke DJ, Bruce W. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography. Phys Ther. 1988 Aug;68(8):1221-5.
- Norris BS, Olson SL. Concurrent validity and reliability of two-dimensional video analysis of hip and knee joint motion during mechanical lifting. Physiother Theory Pract. 2011 Oct;27(7):521-30. doi: 10.3109/09593985.2010.533745. Epub 2011 May 15.
- Finkbiner MJ, Gaina KM, McRandall MC, Wolf MM, Pardo VM, Reid K, Adams B, Galen SS. Video Movement Analysis Using Smartphones (ViMAS): A Pilot Study. J Vis Exp. 2017 Mar 14;(121):54659. doi: 10.3791/54659.
- Kelly M, Jones P, Wuebbles R, Lugade V, Cipriani D, Murray NG. A novel smartphone application is reliable for repeat administration and comparable to the Tekscan Strideway for spatiotemporal gait. Measurement (Lond). 2022 Mar 31;192:110882. doi: 10.1016/j.measurement.2022.110882. Epub 2022 Feb 11.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 93402A830
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .