Ezt az oldalt automatikusan lefordították, és a fordítás pontossága nem garantált. Kérjük, olvassa el a angol verzió forrásszöveghez.

Clinical Features and Airways Inflammation in Never Smokers and Smokers With COPD

2017. szeptember 6. frissítette: Myriam Denguezli, Ministry of Scientific Research, Tunisia

Airway Inflammatory Profile and Clinical Presentation of COPD: A Comparison Between Never Smokers and Smokers

The aim of this study was to investigate the airway inflammatory profile and the clinical presentation of chronic obstructive pulmonary disease (COPD) in never smokers compared to smokers with COPD.

A tanulmány áttekintése

Részletes leírás

40 COPD patients (21 smokers and 19 never smokers) and 28 healthy never smokers were included in the present study. Information about respiratory symptoms and comorbidities were collected. Subjects underwent pulmonary function tests and COPD was defined according to Global Initiative for Chronic Obstructive lung Disease spirometric criteria. Induced sputum was collected to determine total and differential inflammatory cells counts as well as inflammatory mediators (Interleukin-8 (IL-8) and tumor necrosis factor-alpha (TNF-α)). The Mann-Whitney U and the χ2 tests were used for results comparisons. Correlations between symptoms, spirometric parameters, cytokines levels, inflammatory cells and risk factors of COPD were examined with Spearman's rank correlation test.

Tanulmány típusa

Megfigyelő

Beiratkozás (Tényleges)

68

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

40 év és régebbi (Felnőtt, Idősebb felnőtt)

Egészséges önkénteseket fogad

Nem

Tanulmányozható nemek

Összes

Mintavételi módszer

Nem valószínűségi minta

Tanulmányi populáció

Patients were recruited from the department of physiology and functional explorations of Sousse University Hospital. 40 subjects with COPD, according to GOLD criteria (21 current smokers and 19 never smokers) and 28 healthy control subjects participated to the study.

Leírás

Inclusion Criteria:

  • Subjects with COPD, according to GOLD criteria (smokers and never smokers). Moreover, inhaled short-acting β2-agonists were stopped at least 8h before the test and inhaled long-acting β2-agonist were stopped at least 48h before the test.
  • Healthy control subjects : never smokers with normal spirometry and did not have a history of lung disease or chronic respiratory symptoms.

Exclusion Criteria:

  • COPD patients were excluded from the study if they had an exacerbation, a respiratory tract infection or if they used a systemic form of corticosteroid preparation (oral or intravenous injection therapy) or antibiotics within the two months prior to the study entry. Patients with other respiratory disorder like pneumonia, pulmonary emboli, congestive heart failure, lung cancer or tuberculosis were also excluded.

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

  • Megfigyelési modellek: Case-Control
  • Időperspektívák: Visszatekintő

Kohorszok és beavatkozások

Csoport / Kohorsz
Beavatkozás / kezelés
Healthy subjects

Healthy non-smoking subjects were never smokers with normal spirometry and did not have a history of lung disease or chronic respiratory symptoms.

Information about respiratory symptoms and comorbidities were collected. Healthy subjects underwent pulmonary function tests (Spirometry). Induced sputum was collected to determine total and differential inflammatory cells counts as well as inflammatory mediators (Interleukin-8 and tumor necrosis factor-alpha).

Induced sputum was collected and analysed in the three arms (Healthy subjects, Never smokers with COPD and smokers with COPD) The volume of the sputum sample, was treated with an equal volume of 0.1% dithiothreitol. The samples were then vortexed and placed in a shaking water bath at 37°C for 15 min to ensure complete homogeneisation. The suspensions were centrifuged at 400× g and the sputum supernatant stored at -80°C until cytokines analysis. The cell pellet was resuspended in 0.5% bovine serum albumin in phosphate buffered saline and cytospin were made by putting 100 µL of the cell suspension in the funnels.

Slides for differential cell counts were stained with May-Grünwald Giemsa.

All the subjects underwent pulmonary function tests (Healthy subjects, Never smokers with COPD and smokers with COPD).

Pulmonary function parameters were measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the ATS criteria (American Thoracic Society). Reversibility test was performed 15 min after inhalation of 400 µg of Salbutamol (Ventolin, GlaxoSmithKline, Middlesex, UK). All spirometry data were graded for quality and only tests that met high quality scores were used for the final analysis.

Más nevek:
  • spirometria

IL-8 and TNF-α were measured in the sputum supernatant of all the subjects (Healthy subjects, Never smokers with COPD and smokers with COPD).

Commercially available kits were used to detect IL-8 (Human IL-8 Immuno-Biological Laboratories ELISA Kit) and TNF-α (Human TNF-alpha Sigma-Aldrich ELISA Kit) concentrations in the sputum supernatants. The absorbance was measured at 450 nm. The lower limits detection were 2 pg/mL for IL-8 and 5 pg/mL for TNF-α. The intra assay coefficients of variability were 8.7% for IL-8 and 7.7% for TNF- α.

Más nevek:
  • ELISA
COPD Never smokers

Never smokers referred to subjects who had never smoked Airflow limitation in COPD was defined as a post-bronchodilator forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC) ratio <70% and FEV1 reversibility of <12% and 200 mL from baseline values after inhalation of 400 µg of Salbutamol.

Information about respiratory symptoms and comorbidities were collected. Never smoking subjects with COPD underwent pulmonary function tests (Spirometry). Induced sputum was collected to determine total and differential inflammatory cells counts as well as inflammatory mediators (Interleukin-8 and tumor necrosis factor-alpha).

Induced sputum was collected and analysed in the three arms (Healthy subjects, Never smokers with COPD and smokers with COPD) The volume of the sputum sample, was treated with an equal volume of 0.1% dithiothreitol. The samples were then vortexed and placed in a shaking water bath at 37°C for 15 min to ensure complete homogeneisation. The suspensions were centrifuged at 400× g and the sputum supernatant stored at -80°C until cytokines analysis. The cell pellet was resuspended in 0.5% bovine serum albumin in phosphate buffered saline and cytospin were made by putting 100 µL of the cell suspension in the funnels.

Slides for differential cell counts were stained with May-Grünwald Giemsa.

All the subjects underwent pulmonary function tests (Healthy subjects, Never smokers with COPD and smokers with COPD).

Pulmonary function parameters were measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the ATS criteria (American Thoracic Society). Reversibility test was performed 15 min after inhalation of 400 µg of Salbutamol (Ventolin, GlaxoSmithKline, Middlesex, UK). All spirometry data were graded for quality and only tests that met high quality scores were used for the final analysis.

Más nevek:
  • spirometria

IL-8 and TNF-α were measured in the sputum supernatant of all the subjects (Healthy subjects, Never smokers with COPD and smokers with COPD).

Commercially available kits were used to detect IL-8 (Human IL-8 Immuno-Biological Laboratories ELISA Kit) and TNF-α (Human TNF-alpha Sigma-Aldrich ELISA Kit) concentrations in the sputum supernatants. The absorbance was measured at 450 nm. The lower limits detection were 2 pg/mL for IL-8 and 5 pg/mL for TNF-α. The intra assay coefficients of variability were 8.7% for IL-8 and 7.7% for TNF- α.

Más nevek:
  • ELISA
COPD Smokers

Smokers were defined as persons who had smoked > 20 packs of cigarettes in a lifetime and who continue smoking every day.

Airflow limitation in COPD was defined as a post-bronchodilator forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC) ratio <70% and FEV1 reversibility of <12% and 200 mL from baseline values after inhalation of 400 µg of Salbutamol.

Information about respiratory symptoms and comorbidities were collected. Smoking subjects with COPD underwent pulmonary function tests (Spirometry). Induced sputum was collected to determine total and differential inflammatory cells counts as well as inflammatory mediators (Interleukin-8 and tumor necrosis factor-alpha).

Induced sputum was collected and analysed in the three arms (Healthy subjects, Never smokers with COPD and smokers with COPD) The volume of the sputum sample, was treated with an equal volume of 0.1% dithiothreitol. The samples were then vortexed and placed in a shaking water bath at 37°C for 15 min to ensure complete homogeneisation. The suspensions were centrifuged at 400× g and the sputum supernatant stored at -80°C until cytokines analysis. The cell pellet was resuspended in 0.5% bovine serum albumin in phosphate buffered saline and cytospin were made by putting 100 µL of the cell suspension in the funnels.

Slides for differential cell counts were stained with May-Grünwald Giemsa.

All the subjects underwent pulmonary function tests (Healthy subjects, Never smokers with COPD and smokers with COPD).

Pulmonary function parameters were measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the ATS criteria (American Thoracic Society). Reversibility test was performed 15 min after inhalation of 400 µg of Salbutamol (Ventolin, GlaxoSmithKline, Middlesex, UK). All spirometry data were graded for quality and only tests that met high quality scores were used for the final analysis.

Más nevek:
  • spirometria

IL-8 and TNF-α were measured in the sputum supernatant of all the subjects (Healthy subjects, Never smokers with COPD and smokers with COPD).

Commercially available kits were used to detect IL-8 (Human IL-8 Immuno-Biological Laboratories ELISA Kit) and TNF-α (Human TNF-alpha Sigma-Aldrich ELISA Kit) concentrations in the sputum supernatants. The absorbance was measured at 450 nm. The lower limits detection were 2 pg/mL for IL-8 and 5 pg/mL for TNF-α. The intra assay coefficients of variability were 8.7% for IL-8 and 7.7% for TNF- α.

Más nevek:
  • ELISA

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Weight measurement
Időkeret: 6 months
Weight was measured in kilograms for all the participants.
6 months
Height measurement
Időkeret: 6 months
Height was measured in meters for all the participants.
6 months
Forced vital capacity (FVC)
Időkeret: 6 months
FVC was measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the American Thoracic Society criteria.
6 months
Forced expiratory volume in one second (FEV1)
Időkeret: 6 months
FEV1 was measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the American Thoracic Society criteria.
6 months
Sputum induction and collection
Időkeret: 6 months
Sputum induction was conducted by inhalation of nebulised sterile hypertonic saline solution followed by coughing and expectoration of airway secretions. For nebulisation, an ultrasound nebulizer was used for 5-20 min to provide an adequate amount of sample. The subject is asked to cough and expectorate at 5 min intervals.
6 months

Másodlagos eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
BMI determination
Időkeret: 6 months
Weight and height values were combined to report BMI in kg/m2
6 months
Tiffeneau ratio (FEV1/FVC)
Időkeret: 6 months
The calculation of FEV1/FVC allows the identification of obstructive ventilatory defect. A FEV1/FVC < 70 % where FEV1 is reduced more than FVC signifies an obstructive defect.
6 months
Sputum cell counts
Időkeret: 1 month
Four hundred non-squamous cells were counted by two technicians and the mean of the two scores was expressed as percentage of the total cell count. Sputum samples containing >20% of squamous cells and/or with cell viability <70% were excluded from analysis.
1 month
Sputum supernatant analyses
Időkeret: 3 months
IL-8 and TNF-α sputum supernatant concentrations were measured in the sputum supernatant of the three studied groups using ELISA test.
3 months

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Nyomozók

  • Tanulmányi igazgató: Zouhair Tabka, MD PhD, Faculty of medicine of Sousse
  • Kutatásvezető: Amina Mrizak, MSc, Faculty of medicine of Sousse

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete (Tényleges)

2013. szeptember 1.

Elsődleges befejezés (Tényleges)

2016. augusztus 1.

A tanulmány befejezése (Tényleges)

2017. január 1.

Tanulmányi regisztráció dátumai

Először benyújtva

2017. augusztus 24.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2017. szeptember 6.

Első közzététel (Tényleges)

2017. szeptember 7.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Tényleges)

2017. szeptember 7.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2017. szeptember 6.

Utolsó ellenőrzés

2017. szeptember 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Terv az egyéni résztvevői adatokhoz (IPD)

Tervezi megosztani az egyéni résztvevői adatokat (IPD)?

Igen

IPD terv leírása

All IPD that underlie results will be shared in a publication

IPD megosztási időkeret

The data will become available when the article will be accepted by the editorial board of the journal.

Az IPD megosztását támogató információ típusa

  • Tanulmányi Protokoll
  • Klinikai vizsgálati jelentés (CSR)

Gyógyszer- és eszközinformációk, tanulmányi dokumentumok

Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz

Nem

Egy amerikai FDA által szabályozott eszközterméket tanulmányoz

Nem

az Egyesült Államokban gyártott és onnan exportált termék

Nem

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .

3
Iratkozz fel