Ezt az oldalt automatikusan lefordították, és a fordítás pontossága nem garantált. Kérjük, olvassa el a angol verzió forrásszöveghez.

Calcitonin Gene-related Peptide Expression in Human Periodontal Ligament

2021. május 10. frissítette: Javier Caviedes-Bucheli, Institucion Universitaria Colegios de Colombia

The Effect of Orthodontic Forces on Calcitonin Gene-related Peptide Expression in Human Periodontal Ligament

The purpose of this study was to quantify the effect of moderate and severe orthodontic forces on Calcitonin gene-related peptide expression in the healthy human periodontal ligament.

Methodology: 90 human periodontal ligament samples were obtained from healthy premolars where extraction was indicated for orthodontic reasons. Prior to extraction, teeth were divided into 3 groups of 30 samples each: I) Untreated teeth control group; II) Moderate force group: A 56 g force was applied to the premolars for 7 days; and III) Severe force group: A 224 g force was applied to the premolars for 24 hours. All periodontal ligament samples were processed and CGRP was measured by radioimmunoassay.

A tanulmány áttekintése

Állapot

Befejezve

Beavatkozás / kezelés

Részletes leírás

An experimental study was performed according to Colombian Ministry of Health recommendations regarding ethical issues in research involving human tissue. Written informed consent was obtained from each of the patients participating in the study (18-27 years old, healthy, not medicated, and nonsmoking human donors, with premolars extraction indicated for orthodontic reasons). All teeth used were caries- and restoration-free with complete root development determined radiographically (and confirmed visually after extraction), without signs of periodontal disease or traumatic occlusion, and without previous orthodontic forces.

Experimental procedure Periodontal ligament samples were obtained from 90 premolars that were randomly divided into 3 groups of 30 premolars each, as follows: I) Untreated teeth control group (without orthodontic forces); II) Moderate force group; III) Severe force group. Teeth in moderate and severe orthodontic force groups were submitted to tipping and extrusion orthodontic movements.

Orthodontic forces were applied following the exact same methodology that was used in a previous study (15), in which, prior to orthodontic force application, the occlusal surface of the first mandibular molar was raised with a block of resin (Filtek Z350, 3M Espe, Seefeld, Germany) until the premolars were out of occlusion. A convertible standard buccal tube (Orthorganizer, Carlsbad, CA) was bonded over the buccal face of the first molar with resin (Light Bond, Reliance Orthodontic Products Inc, Itasca, IL). An MBT slot size 0.022 bracket (Ref. 702-393 MC, Orthorganizer) was bonded over the buccal face of the premolars. One 0.0017 x 0.025 in titanium molybdenum alloy (TMA) wire cantilever was inserted into each first molar tube and the wire was bent buccally to form a helix.

The cantilever was clinched to the distal end of the tube and exerted a tipping and extrusive force on the premolar. For the teeth in the moderate force group, the activation angle was 45º with a force of 56 g. For the severe force group, the activation angle was 90º with a force of 224 g. For both groups, forces were measured with an orthodontic dynamometer. Once the force was measured, the free-end of the sectional arch was hooked to the bracket with a metallic ligature. Seven days after, the ligature, the sectional arch, the tube, and the resin block were removed in order to perform the extraction procedure.

All teeth were anesthetized with 1.8 mL 4% prilocaine without vasoconstrictor by infiltrative injection for upper premolars and inferior alveolar nerve block injection for lower premolars. Adequate pulpal anesthesia was ascertained with a negative response to an electronic pulp vitality test.

Sample collection Teeth in the control and orthodontic forces group were extracted 10 min after anesthetic application with conventional methods and without excessive injury to the periodontal ligament. Immediately after extraction, PDL samples were obtained from the entire length of the root with a periodontal curette, placed on an Eppendorf tube, snap-frozen in liquid nitrogen, and kept at -70°C until use.

Radioimmunoassay (RIA) PDL samples were defrosted without thermal shock, dried on a filter, and individually weighed on an analytical balance. Neuropeptide was extracted by adding 150 µL of 0.5 mol L-1 acetic acid and double boiling in a thermostat bath for 30 min in accordance with previously reported protocols (9,12,15,18-21).

CGRP expression was determined by competition binding assays using a human CGRP-RIA kit from Phoenix Peptide Pharmaceutical (Ref. RK-015-02, Belmont, CA). Fifty µL of each sample solution were incubated in polypropylene tubes at room temperature for 20 h with 100 µL of primary antibody and 100 µL of different CGRP concentrations (10 pg mL-1 -1280 pg mL-1). Then, 50 µL of 125I-CGRP was added and left incubate for another 24 h. Bound fractions were precipitated by the addition of 100 µL of a secondary antibody (Goat Anti- Rabbit IgG serum), 100 µL of normal rabbit serum, and 500 µL of RIA buffer containing 1% polyethylene glycol 4000. After 2 h of incubation at room temperature, tubes were spun at 3000 rpm for 45 min at 4º C. The supernatants were decanted, and pellet radioactivity was read on a Gamma Counter (Gamma Assay LS 5500; Beckman, Fullerton, CA). Standard curves of authentic peptide were made in buffers identical to the tissue extracts on semi-log graph paper.

Finally, analysis of the binding data assessed the amount of CGRP present in every sample, using the percentage of maximum binding (B/B0%) calculated for each unknown sample, reading across the graph to the point of intersection with the calibration curve, where the corresponding X-axis coordinate is equivalent to the concentration of peptide in the assayed sample.

Statistical analysis Values are presented as CGRP concentration in pmol per mg of PDL. Mean, standard deviation, medians, and maximum/minimum values are presented for each group. Kruskal Wallis test was performed to establish statistically significant differences between groups (P<0.05). LSD posthoc comparisons were also performed.

Tanulmány típusa

Beavatkozó

Beiratkozás (Tényleges)

90

Fázis

  • Nem alkalmazható

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi helyek

    • Metropolitana
      • Bucaramanga, Metropolitana, Colombia
        • Universidad Santo Tomás

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

18 év (Felnőtt)

Egészséges önkénteseket fogad

Igen

Tanulmányozható nemek

Összes

Leírás

Inclusion Criteria:

- Premolars extraction indicated for orthodontic reasons with complete root development determined radiographically (and confirmed visually after extraction)

Exclusion Criteria:

  • Medicated patients,
  • Smokers patients,
  • Premolars with caries or restorations,
  • Premolars with signs of periodontal disease or traumatic occlusion,
  • Premolars with previous orthodontic forces

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

  • Elsődleges cél: Szűrés
  • Kiosztás: Nem véletlenszerű
  • Beavatkozó modell: Párhuzamos hozzárendelés
  • Maszkolás: Nincs (Open Label)

Fegyverek és beavatkozások

Résztvevő csoport / kar
Beavatkozás / kezelés
Nincs beavatkozás: Untreated teeth control group
Premolars without orthodontic forces
Kísérleti: Moderate force group
Premolars were submitted to tipping and extrusion orthodontic movements, the activation angle was 45º with a force of 56 g. Forces were measured with an orthodontic dynamometer. For 7 days
56g force and 224g force
Kísérleti: Severe force group
Premolars were submitted to tipping and extrusion orthodontic movements, the activation angle was 90º with a force of 224 g. Forces were measured with an orthodontic dynamometer. For 24 hours
56g force and 224g force

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Calcitonin gene-related peptide in periodontal ligament
Időkeret: 24 hours stimulation and 7 days stimulation
CGRP expression change in periodontal ligament
24 hours stimulation and 7 days stimulation

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Publikációk és hasznos linkek

A vizsgálattal kapcsolatos információk beviteléért felelős személy önkéntesen bocsátja rendelkezésre ezeket a kiadványokat. Ezek bármiről szólhatnak, ami a tanulmányhoz kapcsolódik.

Általános kiadványok

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete (Tényleges)

2019. június 4.

Elsődleges befejezés (Tényleges)

2019. november 7.

A tanulmány befejezése (Tényleges)

2020. március 10.

Tanulmányi regisztráció dátumai

Először benyújtva

2021. május 5.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2021. május 5.

Első közzététel (Tényleges)

2021. május 11.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Tényleges)

2021. május 13.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2021. május 10.

Utolsó ellenőrzés

2021. május 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Egyéb vizsgálati azonosító számok

  • JCB003

Terv az egyéni résztvevői adatokhoz (IPD)

Tervezi megosztani az egyéni résztvevői adatokat (IPD)?

NEM

Gyógyszer- és eszközinformációk, tanulmányi dokumentumok

Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz

Nem

Egy amerikai FDA által szabályozott eszközterméket tanulmányoz

Nem

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .

Klinikai vizsgálatok a Orthodontic forces

3
Iratkozz fel